1ab 1a (ZSM1-121) Possible with ISG2 (Equivalent to IP44) Enclosure Set pressure range 0.1 to 0.6 MPa (-X202) Micro-load type available Available indicator light Compliant with ZM ejector 2ab contact type (Option) With light (Refer to Series IS2761.)
(Example) 2000mm lead wire length Cover Groove Pin 300mm 600mm 1000mm 1500mm 2000mm 2500mm 3000mm 5000mm Lever 6 10 15 20 25 30 50 DC indicator Socket DXT170-71-1 For DC SY114-5LOZ SY100-30-4A-20 For AC SY114-1LOZ SY100-30-1A-20 Connector Hook Lead wire 10 World Wide Support... Europe ENGLAND SMC Pneumatics (U.K.) Ltd.
Yes Note) None Note) Yes Yes (W/o indicator light) Yes (W/o indicator light) Note) Note) Coil voltage Note) 1 2 3 4 5 6 9 100 VAC (50/60 Hz) 200 VAC (50/60 Hz) 110 VAC (50/60 Hz) 220 VAC (50/60 Hz) 24 VDC 12 VDC Note) DIN is applicable to VQZ2000/3000. Bracket Assembly Note) Part no.
Coil voltage 1 2 3 4 5 6 9 100 VAC (50/60 Hz) 200 VAC (50/60 Hz) 110 VAC (50/60 Hz) 220 VAC (50/60 Hz) 24 VDC 12 VDC Other Valve model Pilot valve model Note) VQZ115-L VQ110-M Note) For the special voltages, please consult with SMC. VQZ115-M VQ110-L 4-14-41
VQZ2000-SVQZ2000 (1) (1) VQZ3000-SVQZ3000 (2) (2) (2) Coil voltage (2) 100V AC (50/60Hz) 200V AC (50/60Hz) 110V AC (50/60Hz) 220V AC (50/60Hz) 24V DC 12V DC Others 1 2 3 4 5 6 9 Note 1) L, LO, M and MO types are attached with light and surge voltage suppressors as standard. Note 2) DIN style is applicable to VQZ2000, 3000.
Coil voltage 1 100V AC (50/60Hz) 200V AC (50/60Hz) 110V AC (50/60Hz) 220V AC (50/60Hz) 24V DC 12V DC Others Valve style Pilot valve style 2 3 VQZ115l-lLl VQ110l-lMl 4 VQZ115l-lMl VQ110l-lLl 5 6 9 Consult SMC when requiring grommet, AC specification and others. 2.10-39
Coil voltage 1 2 3 4 5 6 9 100 VAC (50/60 Hz) 200 VAC (50/60 Hz) 110 VAC (50/60 Hz) 220 VAC (50/60 Hz) 24 VDC 12 VDC Other Note) For the special voltages, please consult with SMC.
With (1) Without (1) Coil voltage 100V AC (50/60Hz) 200V AC (50/60Hz) 110V AC (50/60Hz) 220V AC (50/60Hz) 24V DC 12V DC Others (1) With With (Without light) 1 (1) 2 Note 1) DIN is applicable to VQZ 200 and 300.
Type: Block and Plate for Connection, Type: Air Supply / Exhaust End Block Assembly (Tie-Rod Base) SV1000, Number of Inputs/Outputs: -, Connector: -, Mounting Method: DIN rail mounting, Port pipe connection port diameter: Plug, Rated Voltage: -, Specification: Internal Pilot Specifications, Thread standard: -, Dimension: -, Applicable valve: -, Pressure reduction port: -, Option: -
Type: Block and Plate for Connection, Type: Air Supply / Exhaust End Block Assembly (Tie-Rod Base) SV1000, Number of Inputs/Outputs: -, Connector: -, Mounting Method: DIN rail mounting, Port pipe connection port diameter: ø8 single-action pipe fitting, Rated Voltage: -, Specification: Internal Pilot Specifications, Thread standard: -, Dimension: -, Applicable valve: -, Pressure reduction
Type: Block and Plate for Connection, Type: Air Supply / Exhaust End Block Assembly (Tie-Rod Base) SV1000, Number of Inputs/Outputs: -, Connector: -, Mounting Method: DIN rail mounting, Port pipe connection port diameter: ø5/16" single-action pipe fitting, Rated Voltage: -, Specification: Internal Pilot Specifications, Thread standard: -, Dimension: -, Applicable valve: -, Pressure
SV1000 NO SIZE RATING. .37448 lb. 2I.
The use of 34 pin connectors allows up to 16 stations with double solenoids.Fluid: air, Operating pressure range: -100kPa to 0.7MPa, Response time ms (at 0.5MPa): 18 or less, Coil rated voltage: 12, 24VDC, Ambient and fluid temperature: -10 to 50 C, Enclosure: IP67 (based on IEC529) SV1000 SOLENOID VALVE, 5-PORT. VALVE, DBL SOL, PLUG-IN. VALVE. SV1000 NO SIZE RATING. .16975 lb. 2F.
SV1000 OTHER SIZE RATING. .25800 lb. 1I.
The use of 34 pin connectors allows up to 16 stations with double solenoids.Fluid: air, Operating pressure range: -100kPa to 0.7MPa, Response time ms (at 0.5MPa): 18 or less, Coil rated voltage: 12, 24VDC, Ambient and fluid temperature: -10 to 50 C, Enclosure: IP67 (based on IEC529), VALVE, CASSETTE W/MFLD BLOCK, VALVE, SV1000 SOLENOID VALVE, 5-PORT, UG, SV1000 BUILT IN FITTING1
The use of 34 pin connectors allows up to 16 stations with double solenoids.Fluid: air, Operating pressure range: -100kPa to 0.7MPa, Response time ms (at 0.5MPa): 18 or less, Coil rated voltage: 12, 24VDC, Ambient and fluid temperature: -10 to 50 C, Enclosure: IP67 (based on IEC529), VALVE, SOL, VALVE, SV1000 SOLENOID VALVE, 5-PORT, 2F, SV1000 NO SIZE RATING, .25492 lb
The use of 34 pin connectors allows up to 16 stations with double solenoids.Fluid: air, Operating pressure range: -100kPa to 0.7MPa, Response time ms (at 0.5MPa): 18 or less, Coil rated voltage: 12, 24VDC, Ambient and fluid temperature: -10 to 50 C, Enclosure: IP67 (based on IEC529), VALVE, DBL SOL, PLUG-IN, VALVE, SV1000 SOLENOID VALVE, 5-PORT, 2E, SV1000 NO SIZE RATING, .29475
The use of 34 pin connectors allows up to 16 stations with double solenoids.Fluid: air, Operating pressure range: -100kPa to 0.7MPa, Response time ms (at 0.5MPa): 18 or less, Coil rated voltage: 12, 24VDC, Ambient and fluid temperature: -10 to 50 C, Enclosure: IP67 (based on IEC529), VALVE, DBL SOL, PLUG-IN, VALVE, SV1000 SOLENOID VALVE, 5-PORT, 2G, SV1000 NO SIZE RATING, .26819
The use of 34 pin connectors allows up to 16 stations with double solenoids.Fluid: air, Operating pressure range: -100kPa to 0.7MPa, Response time ms (at 0.5MPa): 18 or less, Coil rated voltage: 12, 24VDC, Ambient and fluid temperature: -10 to 50 C, Enclosure: IP67 (based on IEC529), VALVE, SINGLE, SUB PLATE, VALVE, SV1000 SOLENOID VALVE, 5-PORT, WF, SV1000 BUILT IN FITTING(>1/4