pressure 80 80 40 Suction flow (l/min(ANR)) Air consumption (l/min(ANR)) 1 2 3 4 5 6 7 8 Left Right Vacuum pressure (kPa) Vacuum pressure (kPa) 70 ZA1071-K15L-FP1-M2 ZA1051-Q15L-FB-M1 ZA-BP1 60 60 30 Vacuum (V) port 50 40 40 20 Air consumption 30 20 20 Suction flow 10 10 0 0.6 0.4 0.2 0.5 0.3 0.1 0 8 6 4 2 Suction flow (l/min(ANR)) Supply pressure (MPa) 851 Series ZA Specifications General
Norte Parque Industrial Valle Grande, Lampa Santiago, Chile TEL: 02-270-8600 FAX: 02-270-8601 SWEDEN SMC Pneumatics Sweden AB Ekhagsvgen 29-31, S-141 05 Huddinge, Sweden TEL: 08-603-07-00 FAX: 08-603-07-10 ARGENTINA SMC Argentina S.A.
C Facility water temp. +15C Circulating fluid rated flow rate L/min 4 30 40 40 (1.1 [gal]/min) (7.9 [gal]/min) (10.6 [gal]/min) (10.6 [gal]/min) Facility water minimum necessary flow rate L/min 10 20 25 40 (2.6 [gal]/min) (5.3 [gal]/min) (6.6 [gal]/min) (10.6 [gal]/min) Operating temperature range C 20 to 90 Temperature stability *1 C 0.3 Circulating fluid *2 Galden HT200 or FluorinertTM
Both sides M Special specifications 5 LOZ SX 3 2 40 16 16 stations For special specifications, indicate separately by the manifold specification sheet. This also includes the number of blanking plate assemblies. When special wiring is required on manifold with 2 to 8 stations, please use the manifold specification sheet.
Refer to Handling Precautions for SMC Products (M-E03-3) for Safety Instructions and Vacuum Equipment Precautions. 50 40 40 40 30 20 20 20 Caution Maximum suction flow 10 Refer to the vacuum equipment model selection on Best Pneumatics No.r for the selecting and sizing of Series ZQ. 0 0.1 0.2 0.3 0.4 0.5 0 5 10 15 20 25 Suction flow (l/min(ANR)) Supply pressure (MPa) 3 Space Saving Vacuum
Mode button 1s Set button 1s or Mode button 1s Set button 1s B D C Fig. 40 No.DIG-31900-OM002 49 B Mode button 1s Set button 1s or Mode button 1s Set button 1s P constant I constant D constant Fig. 40-1 C Mode button 1s Set button 1s or Mode button 1s Set button 1s P constant I constant D constant Fig. 40-2 D Mode button 1s Set button 1s or Mode button 1s Set button 1s P constant
(Only for HRZ010-W*S) 0, 15 to 40 LPM 0, 4 to 10.6 GPM 6 LOW FLOW 0, 8 to 40 LPM 0, 2.1 to 10.6 GPM (Only for HRZ010-W*S) 7 FLOW UNIT LPM, GPM Allows the selection of the unit of flow rate. 8 PRESS UNIT MPa, PSI Allows the selection of the unit of pressure. 9 SLAVE ADRS. 1 to 16CH Allows the selection of the slave address for serial RS-485 communication.
: 4-48 32 : 1-12 65 : M5 x 0.8 93 : M30 x 3.5 05 : 5-40 33 : 1 1/8-7 66 : M6 x 0.75 94 : M36 x 4.0 06 : 5-44 34 : 1 1/8-12 67 : M6 x 1.0 95 : M16 x 1.25 07 : 6-32 35 : 1 1/4-7 68 : M8 x 1.0 96 : M36 x 1.5 08 : 6-40 36 : 1 1/4-12 69 : M8 x 1.25 97 : M36 x 2.0 09 : 8-32 37 : 1 3/8-6 70 : M10 x 1.25 10 : 8-36 38 : 1 3/8-12 71 : M10 x 1.5 11 : 10-24 39 : 1-14 72 : M12 x 1.5 12 : 10-32 40 : 1
Norte Parque Industrial Valle Grande, Lampa Santiago, Chile TEL: 02-270-8600 FAX: 02-270-8601 SWEDEN SMC Pneumatics Sweden AB Ekhagsvgen 29-31, S-141 05 Huddinge, Sweden TEL: 08-603-07-00 FAX: 08-603-07-10 ARGENTINA SMC Argentina S.A.
Applicable cylinder bore size (mm) Elbow type Universal type Port size Metric size Inch size Flat head screwdriver 3.2 4 6 8 10 12 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" 1/2" AS121F-M5 AS131F-M5 6, 10, 16, 20 M5 x 0.8 AS221F-01 AS231F-01 20, 25, 32 R 1/8 AS221F-02 AS231F-02 20, 25, 32, 40 R 1/4 AS321F-02 AS331F-02 40, 50, 63 R 1/4 AS321F-03 AS331F-03 40, 50, 63 R 3/8 AS421F-04 AS431F-04 63, 80,
: 4-48 32 : 1-12 65 : M5 x 0.8 93 : M30 x 3.5 05 : 5-40 33 : 1 1/8-7 66 : M6 x 0.75 94 : M36 x 4.0 06 : 5-44 34 : 1 1/8-12 67 : M6 x 1.0 95 : M16 x 1.25 07 : 6-32 35 : 1 1/4-7 68 : M8 x 1.0 96 : M36 x 1.5 08 : 6-40 36 : 1 1/4-12 69 : M8 x 1.25 97 : M36 x 2.0 09 : 8-32 37 : 1 3/8-6 70 : M10 x 1.25 10 : 8-36 38 : 1 3/8-12 71 : M10 x 1.5 11 : 10-24 39 : 1-14 72 : M12 x 1.5 12 : 10-32 40 : 1
Maximum suction flow (l/min(ANR)) Air consumption (l/min(ANR)) Maximum vacuum pressure (kPa) Maximum vacuum pressure (kPa) Maximum vacuum pressure -80 -80 60 -60 -60 50 40 -40 -40 30 Air consumption 20 -20 -20 10 Maximum suction flow Suction flow (l/min(ANR)) 25 20 15 10 5 0 0.1 0 0.2 0.3 0.4 0.5 0.6 Supply pressure (MPa) 13-9-3 4 Series ZQ Specifications Ejector Weight Switch and suction
Both sides M Special specifications 5 LOZ SX 3 2 40 16 16 stations For special specifications, indicate separately by the manifold specification sheet. This also includes the number of blanking plate assemblies. When special wiring is required on manifold with 2 to 8 stations, please use the manifold specification sheet.
0.3 0.4 0.5 0.6 Suction flow (l/min(ANR)) Supply pressure (MPa) ZQ110 Exhaust characteristics ZQ110 Flow characteristics Maximum suction flow (l/min(ANR)) Air consumption (l/min(ANR)) Maximum vacuum pressure (kPa) Maximum vacuum pressure (kPa) Maximum vacuum pressure -80 -80 60 -60 -60 50 40 -40 -40 30 Air consumption 20 -20 -20 10 Maximum suction flow Suction flow (l/min(ANR)) 25 20 15
Port R Operating Fluid and Ambient Temperature Operating fluid temperature (C) (3) Vacuum Ambient temperature (C) Temperature conditions Air (Standard) Oil (Standard) (V) Port P Port A Maximum Minimum 60 5 (1) 40 5 40 40 5 5 (2) Note 1) Dew point: 5C or less Note 2) 500 cSt or less Note 3) V in parentheses is option symbol. Option Material No.
VXZ2230 VXZ2232 VXZ2240 VXZ2242 VXZ2350 VXZ2352 VXZ2360 VXZ2362 H Y F X E W D U V C S T B K R A J N Q N 79.5 87.5 101.5 106.5 L 108 117 130 135 1 4 3 8 , 28 35 43 45 26 30 38 43 14 17 22 22 7.5 8.5 9 9 24 33 42 47 1.6 2.3 2.6 2.6 22 28 36 42 5.5 6.5 6.5 6.5 40 52 65 70 6 7 7 7 11 14 18 21 93 102 115.5 120.5 25 25 28 28 89 97 112 117 67 75 87 92 50 63 80 90 23 23 25.5 25.5 35 35 40 40 25.5
Air Saving Valve Pressure Valve Flow Valve Series ASR/Series ASQ Air consumption reduction ratio (%) 40 Working stroke pressure (MPa) 40% reduction in air consumption 40% reduction in air consumption 30 0.9 0.7 20 0.5 10 0.3 Cuts air consumption by operating the return stroke at a reduced pressure.
Norte Parque Industrial Valle Grande, Lampa Santiago, Chile TEL: 02-270-8600 FAX: 02-270-8601 SWEDEN SMC Pneumatics Sweden AB Ekhagsvgen 29-31, S-141 05 Huddinge, Sweden TEL: 08-603-07-00 FAX: 08-603-07-10 ARGENTINA SMC Argentina S.A.
"AC Only "' Not aveilable WDC Solnold Typo NVS 4024, 'm34 03 = 1'r0v 50Hz U = 2mV fiHz 07 = 24VAC ffiHz t09 = 115/120V 6OHz 100/110V 5OHz t10 = 23o/21t0V 60Hz?
Material Applicable blow gun model Model Male thread nozzle 1 to 2.5 Male thread nozzle 3 to 4 Width across flats 17 Nozzle type P5670129-01 P5670129-01F P5670129-02 P5670129-02F HNBR Fluororubber HNBR Fluororubber VMG1mm-m-01 to 04 VMG1mm-m-05 to 07 m25 VMG1m-mm-1 to 04 Width across flats 17 m23.5 VMG1m-mm-05 to 07 Cover for copper extension nozzle (mm) Nozzle cover part no.