SMC Corporation of America
Elite Part Number Search
Search Results "SS5YJ3-S31-13-M3"

9 7 22 14 4 11 15 12 3 24 13 23 22 7 4 11 MXH16, 20 (16, 20) 20 6 21 17 2 1 19 5 18 18 8 10 4 7 22 23 13 24 3 12 11 Parts list Parts list Description Material Note Description Material No.

Table 4 BoltTightening torque Size Bolt Recommended tightening torque 10 M3 0.63 Nm 15 20 M4 1.50 Nm 30 M5 3.00 Nm 40 Fig.8 Mounting 2 Using a plate with tapped holes (Refer to Fig. 9). L dimension when the unit is used as a flange is shown in the table below.

Mounting with bracket Fix the bracket to the product with the set screws M3 x 5 L (2 pcs.) or M4 x 5 L (2 pcs.) supplied. The required tightening torque is 0.5 to 0.7 Nm for the M3 set screws and 1.4 to 1.6 Nm for the M4 set screws.

3 Port Air Operated Valve Series SYJA300 Model Compact/Lightweight Copper free Effective area (mm2) (Cv) Valve model Actuation Port size Weight (g) Pilot port size SYJA312-M3 N.C. M3 X 0.5 Body ported 0.9 (0.05) 18 There are no copper parts that come in contact with the media; suitable for copper free applications SYJA322-M3 N.O.

Withstand voltage -13No.PF-OMA1011-A Mounting and Installation Installation Mounting by panel mount adapter Fix the panel mount adapter to the Controller with the set screws M3 x 8L (2 pcs.) as attached.

Round head screw (M3 x 8) 4 pcs. EX600-ZMV2 (Specialized for the SY series) Enclosed parts: Round head screw (M4 x 6) 2 pcs. Round head screw (M3 x 8) 2 pcs. -103No.EX-OMU0028-D 3.

Round head screw (M3 x 8) 4 pcs. EX600-ZMV2 (Specialized for the SY series) Enclosed parts: Round head screw (M4 x 6) 2 pcs. Round head screw (M3 x 8) 2 pcs. -114No.EX-OMW0006-D 3.

3.5 6 34 37.5 9.5 13.5 6.5 9 35 38.5 9.5 13.5 7 9.5 38.5 42 6.5 9 6.5 9 38.5 42 38 41.5 6.5 10.5 10 14 Bore size (mm) Long stroke 32 40 9.5 13 17.5 23.5 31.5 35 7 10.5 15 21 34 37.5 10 13.5 18 24 35 38.5 10.5 14 18.5 24.5 38.5 42 10 13.5 10 13.5 18 24 18 24 38.5 42 38 41.5 Bore size (mm) 3.8-13 World Wide QS\E Support...

Flashes during stand-by for stop or antifreezing function, or independent operation of the pump. y [ALARM] lamp Flashes with buzzer when alarm occurs. u [ ] lamp Lights up when the surface of the uid level indicator falls below the L level. 13 Accumulation time reset Reset function when the pump, the fan or the compressor is replaced.

Specifications 0.01 m (95% filtered particle diameter) Filtration of outlet air Max. 0.1 mg/m3 (ANR) (0.08 ppm) Note) Outlet air oil mist concentration (Prior to oil saturated 0.01 mg/m3 (ANR) or less, (0.008 ppm or less)) Note) With inlet air oil mist concentration of 30 mg/m3 (ANR) (24 ppm) Applicable Model Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080

Mount the sensor head using two M3 screws (not supplied with the product). M3 screws M3 screws M3 screws Due to the construction of the sensor, the sensor head housing is shared with GND. Install and supply power with great caution to avoid short-circuit with the +24 V power supply. The detection port is opened to detect static electricity.

No.ZL3-OM00601-B 13. Troubleshooting When any failure occurs to the product, perform the following trouble shooting. Failure phenomenon Possible causes Countermeasure No.

A B 32 40 9 13 6 8.5 (mm) Auto Switch Proper Mounting Position/Long Stroke D-A72/A7H D-A80H/A73C D-A80C/F7/J79 D-F7W/J79W D-F7V/F7WV D-F79F/J79C D-F7BAL/F7BAVL Auto switch model D-A73 D-A80 D-A79W D-F7NTL Bore size A B A B 10 13.5 18 24 A B 7 10.5 15 21 A B 15 18.5 23 29 32 40 9.5 13 17.5 23.5 Note ) Adjust the auto switch after confirming the operating conditions in the actual setting.

In locations where high frequency occurs. 13. In locations where damage is likely to occur due to lightning. 14.

14 12.5 16 5 5.5 9 10 8.5 12 7 6 11.5 13.5 16.5 22.5 5 (2.5) 8 8.5 12 13 11.5 15 10 9.5 15 17 19.5 25.5 8 8.5 3.5 1 1.5 7.5 4.5 (2) Bore size (mm) 10 (7.5) 12 (9.5) 14.5 (12) 20.5 (18) ( ): Denotes the values of D-A93.

Hard anodized Chromated Countersunk head screw Nut Rod seal Piston seal Gasket Plug Nickel plating Nickel plating Zinc chromated D-X 23 MXH Series Dimensions: 6 LT 9 15 LA LB 8 J x M3 x 0.5 Depth 5 3 x M4 x 0.7 through Pilot hole dia 3.3 2 x 3 x 6 counterbore depth 3.3 2 x 2 x M5 x 0.8 Cylinder port (With plug for port) 4 x M3 x 0.5 Depth 5.5 2 x M5 x 0.8 Cylinder port 4 x M3 x 0.5 Depth

x 0.5 Depth 6.5 LA LB 8 MXS MXQ Guide rail width 5 3 x M4 x 0.7 through Bottom hole dia 3.3 6 x 6 counterbore depth 3.3 4 x M3 x 0.5 Depth 5.5 Plug for port (Hexagon socket head set screw) 4 x M5 x 0.8 x 4 l 2 x M5 x 0.8 6.5 5 MXF 4 x M3 x 0.5 Depth 4.8 MXW 17 38 39 MXJ 19 10 18 19 18 15 MXP 5 5.5 10 5.5 5.5 MXY NS 4 9 10.5 8.5 31 + Stroke MTS 39.5 + Stroke 16 4 x M3 x 0.5 Depth 4.8 10 5

Panel mount adapter ZS-26-B With set screw M3 x 8L (2 pcs.) and waterproof seal Panel mount adapter + Front protective cover ZS-26-C With set screw M3 x 8L (2 pcs.) and waterproof seal Front protective cover ZS-26-01 48 conversion adapter ZS-26-D It is an adapter for attaching PSE200A series in the panel cut size of PSE100 series. -8No.PS-OMW0012-C Summary of Product parts Names of individual

Location where vacuum pressure is measured Piping length (m) Vacuum source Adjust the measured vacuum pressure using a regulator to be the value in the graphs below. 0 -0.001 -0.002 -0.003 -0.004 -0.005 -0.006 -0.007 -0.008 -0.009 -0.010 -0.011 -0.012 11-CJ2 11-CM2 11-CQ -0.027 13-MXS16 Vacuum pressure (MPa) Vacuum pressure (MPa) -0.028 13-MJP 13-MXS20 -0.029 11-CU -0.030 13-MXS25 -0.031

ZQ-OM01401-B / / ZQA No.ZQ-OM01401-B 2 1. 5 2. 9 3. 11 3.1. 11 3.2. 12 3.3. 13 3.4. 14 3.5. 16 4. 17 5. 19 6. 20 7. 21 8. 28 9. 32 10. 35 11. 37 12. 40 13. 42 1 - No.ZQ-OM01401-B /ZQA *1) *2) (ISO/IEC)(JIS) *1) ISO 4414: Pneumatic fluid power -General rules relating to systems ISO 4413: Hydraulic fluid power -General rules relating to systems IEC 60204-1: Safety of machinery