M3 x 0.5 x 3L M8 x 1.25 x 8L (Bolt holder) (Hexagon socket head set screw) 31 0.5 45 45 3 3 5.3 5.3 250.2 250.2 16 32 2-M3 x 0.5 through 6.5 counter bore depth 5 (Same on the opposite side) 3.4 through 3 3 45 45 5.5 M2.5 x 0.45 x 6L (Cap screw) M3 x 0.5 x 12.5L (Hexagon bolt) and M3 x 0.5 (Hexagon nut) 2-M3 x 0.5 through Steel ball Plug 2-M3 x 0.5 through 2.75 (11) (10+ST) 250.2 4 Part no
Minimum Auto Switch Mounting Stroke (mm) D-A9V D-A7 D-A80 D-A73C D-A80C D-F7W D-J79W D-F7BA D-F79F D-F7NT D-M9WV D-M9AV D-F7WV D-F7BAVL D-M9V D-F7V D-J79C D-M9 D-F7 D-J79 No. of auto switches mounted D-M9W D-M9A D-A7H D-A80H D-A79W D-A9 10 (5) 15 (10) 15 (5) 1 pc. 5 5 10 15 (5) 15 20 (10) 10 15 15 (10) 2 pcs. 5 10 15 15 (5) 20 20 (15) Note) The dimensions stated in ( ) shows the minimum stroke
Fig 9-15 Required facility water flow (HRR050-W-20-) 9.7.2 HRR050-W-4030 Facility water flow rate [L/min] 25 20 15 10 5 0 0 5 10 15 20 25 30 35 40 45 Facility water inlet temperature [] The amount of the facilitywater for the opution with rated circulating fluid, cooling capacity which is described in fig.9-10.
Mounting by bracket Fix the bracket to the product with the set screws M3 x 5 L (2 pcs.) as attached. The tightening torque of the set screws must be 0.5 to 0.7 Nm. Mounting by panel mount adapter Fix the panel mount adapter to the product with the set screws M3 x 8 L (2 pcs.) as attached.
8 171 161 9 190 180 10 209 199 11 228 218 12 247 237 13 266 256 14 285 275 15 304 294 16 323 313 17 342 332 18 361 351 19 380 370 20 399 389 7
5 15 10 10 2 pcs. 10 15 20 2 pcs. 5 10 15 15 20 20 25 15 32, 40, 50 32, 40, 50 5 15 10 5 1 pc. 10 10 20 1 pc. 5 5 10 15 15 20 25 15 Besides the models listed in How to Order, the following auto switches are applicable.
Without flow adjustment valve (using ZS-33-M) With flow adjustment valve (using ZS-33-MS) Mount the product with bracket using M3 screws (4 pcs) or equivalent. Screws are prepared by customer. Refer to the dimension drawing (page 84) for the bracket thickness and mounting hole dimensions.
For standard installation, turn 15 to 30 using tool, after fastening by hand. Pay attention not to over torque the product. Suitable screw torque (Nm) Body size M3 0.07 M5 0.3 1/8 1 1/4 1.5 3/8 4 1/2 10 15-8-6 Flow Control Equipment Precautions Series ASN2 Handling of One-touch Fittings Caution Selection 1. Refer to page 15-1-11 for One-touch Fitting. Warning 1.
For standard installation, turn 15 to 30 using tool, after fastening by hand. Pay attention not to over torque the product. Suitable screw torque (Nm) Body size M3 0.07 M5 0.3 1/8 1 1/4 1.5 3/8 4 1/2 10 15-8-6 Flow Control Equipment Precautions Series ASN2 Handling of One-touch Fittings Caution Selection 1. Refer to page 15-1-11 for One-touch Fitting. Warning 1.
24 5 19 14.5 11.5 15 10 5 25 19 M22 X 1.5 20.5 4.5 17.5 15 31.5 27 24 Panel Mounting Style CJPB B C E G H K MM NN 5st 10st F 15st R 5st 10st S 15st W Q 5st 10st Z Bore (mm) 6 10 15 A 15st 7 12 13.9 6 12.5 19.5 26.5 8.5 9 3.5 M3 X 0.5 M10 X 1.0 9 18.5 25.5 32.5 3 27.5 34.5 41.5 3 10 19 22 6 14.5 21 28 12 12 3.5 M4 X 0.7 M15 X 1.5 13 20.5 27 34 4 32.5 39 46 5 12 27 31 7 16.5 22.5 29 19 14
PF2D5--1 (With voltage output type) PF2D540-19 Display unit (PF2D30/31) 186 Sensor unit 78 86 Brown 6 2 Analog output Switch output or Pulse output Main circuit Main circuit 56 8 4 Load + 12 to 24 VDC 15 White 7 3 Black 5 1 Blue Load is an analog input equipment such as a voltmeter.
With the exhaust of air pressure, the valve (15) is closed by the force of the spring (13) and is sealed by the valve seal (14). In the case of the XLFV, port P (19) is normally pressurized, and the valve (15) opens when the solenoid valve (18) is turned ON, and closes when it is turned OFF. Operation is the same as that of the XLF.
8 58 11 81 1/4 24 10 24 63 20 depth13 90 77 13 35.5 30 M27 x 3 33 9 69 13 100 1/4 27.5 10 27.5 80 23 depth 15.2 105 88 17 45 41 M30 x 3.5 36 14 86 15 121 3/8 31 15 31 100 26 depth 17.5 132 106 26 56 50 M39 x 4 45 21 106 17 146 3/8 36 15 36 Note) Body dimensions are the same with or without auto switches.
With the exhaust of air pressure, the valve (15) is closed by the force of the spring (13) and is sealed by the valve seal (14). In the case of the XLFV, port P (19) is normally pressurized, and the valve (15) opens when the solenoid valve (18) is turned ON, and closes when it is turned OFF. Operation is the same as that of the XLF.
Single round shaft: ClRA1BT Double shaft (round shaft, with four chamfers): ClRA1BJ Double round shaft: ClRA1BK D D D H H H H UU UU M N 0 0.2 G D L 0 0.2 [mm] [mm] [mm] Size D (g6) H Size D (g6) G H M N UU L Size D (g6) H UU 30 8 25 50 15 36 63 17 41 80 20 50 100 25 60 30 8 6 25 10 8 75 7.8 50 15 11 36 20 15 118 14 63 17 13 41 22 17 139 16 80 20 15 50 25 20 167 19 100 25 19 60 30 25 202 24
Note Lead wire length: 2m With mounting screws (M3 x 5L: 2 pcs.)
Part number Description Remarks ZS-28-A Power and output lead wire and connector Length: 2 m ZS-28-B Bracket Mounting screw (M3 x 5 L) 2 pcs. ZS-28-C-1 Sensor connector 1 pc. ZS-27-C Panel mount adapter Mounting screw (M3 x 8 L) 2 pcs. ZS-27-D Panel mount adapter + Front protective cover Mounting screw (M3 x 8 L) 2 pcs.
) 255 points(When 2 stations are occupied) CC-Link (When 2 stations are occupied) Absolute LECSC (CC-Link) PC30 LECSS (SSCNET III) SSCNET III Absolute Note4) LECSB-T ON/OFF signal 15 points (max. 255 points)Note2) ON/OFF signal 16 programs (max. 256 Programs)Note2) PA01 Pulse train Absolute (Pulse input / Positioning) CC-Link 31 points(When 1 station is occupied) 255 points(When 2 stations
Mounting same side MGC D-C7 D-C8 D-H7 D-H7W D-H7BAL D-H7NF D-C73C D-C80C D-H7C 50+45(n2) 50 15 10 15+45( n2 ) (n=2, 4, 6) MGF 2 60+45(n2) 60 15 10 CY1 15+50( n2 ) (n=2, 4, 6) MY1 2 65 15 10 65+50(n2) 20+50( n2 ) (n=2, 4, 6) 2 65 20 D-H7LF 10 15+50( n2 ) (n=2, 4, 6) 2 D-B5/B6 D-G5NTL 10 75 15 75+55(n2) 20+50( n2 ) (n=2, 4, 6) 2 15 75 20 D-B59W D-A3A D-G39A D-K39A D-A44A 10 100+100(n2) 35+30