Type 41, 42, and 43 base mounted manifold gasket part number.: SY□000-GS-2(-Q) (10 pcs./set: mounting screws and gasket)
Valve part numbers: SY3140, SY5140, SY7140, SY9140, etc.
Note) For type 41 and 42 SY5000/7000 series manifolds, when there is a “-Q” (CE-compliant product) suffixed to the part number, suffix a “-Q” to the gasket assembly part number as well .
Dimensions 46.5 Cover 26.5 12 14 Turn counterclockwise until the cover stops. 42 Pull R1/4 2) Use a flat head screwdriver (with a 2.9 mm blade width) to set the limit indicator. Be careful not to bend other needle or damage the dial plate.
Port size VCB2 VCW20-12-01A 34 40 25 30 12.8 12.8 5 4.5 6 13 1/8, 1/4 VCW30-12-02A 42 52 30 40 19 19 6 5.5 7 19 1/4, 3/8 VCB3 VCW30-12-04A Note 1) 48 56 36 44 23 23 6 5.5 7 23 1/2 VCW40-12-02A 42 52 30 40 23 23 6 5.5 7 19 1/4, 3/8 VCB4 VCW30-12-04A Note 1) 48 56 36 44 23 23 6 5.5 7 23 1/2 VCW40-12-06A 56 65 44 53 28.2 28.2 6 5.5 7 26 3/4 2 mounting screws (for mounting bracket) are included
Valve model Port size L J H G F E D C A B VCW20-12-01A VCB2 1/8, 1/4 13 6 4.5 5 12.8 12.8 30 25 40 34 VCW30-12-02A 1/4, 3/8 19 7 5.5 6 19 19 40 30 52 42 VCB3 VCW30-12-04A 1/2 23 7 5.5 6 23 23 44 36 56 48 VCW40-12-02A 1/4, 3/8 19 7 5.5 6 23 23 40 30 52 42 VCW30-12-04A VCB4 1/2 23 7 5.5 6 23 23 44 36 56 48 VCW40-12-06A 3/4 26 7 5.5 6 28.2 28.2 53 44 65 56 Two mounting screws (for mounting
KQ2P-04 KQ2P-06 KQ2P-08 KQ2P-10 KQ2P-12 16 4 32 6 18 6 35 8 20.5 8 39 10 Series SY3000 SY5000 SY7000 Part No. 22 10 43 12 SY3000-52-2A 24 12 45.5 14 SY5000-52-2A SY3000/5000 DIN rail dimensions and weight SY7000-52-2A VZ1000-11-1Blocking disk indication stickers Refer to L dimensions Enter a number from the DIN rail dimension table below in the .
AS Series How to Order 2 2 0 01 06 W2 AS 1F Body size 2 1 M5 standard 1/8, 1/4 standard 3/8 standard 1/2 standard 3 4 Metric size Applicable tubing O.D. Note) Elbow 06 08 10 12 6 8 10 12 Control type Meter-out Meter-in 0 1 Note) For applicable tubing O.D. selection, refer to the Model on page 603.
G Stainless steel Body material Applicable tubing O.D. 04 06 08 10 12 4 6 8 10 12 Body size 2 Elbow Type 2 3 4 5 6 M5 1/8 1/4 3/8 1/2 Control type Port size 0 1 Meter-out Meter-in M5 01 02 03 04 M5 x 0.8 R1/8 R1/4 R3/8 R1/2 With one-touch fitting 1
(UL standard V-0) Applicable model: ASV310F, ASV410F, ASV510F Inch size Note) Elbow: M3, M5 only Port size AS 04 06 08 10 12 03 07 09 11 13 4 6 8 10 12 5/32" 1/4" 5/16" 3/8" 1/2" M3 M5 U10/32 01 02 03 04 M3 x 0.5 M5 x 0.8 10-32 UNF 1/8 1/4 3/8 1/2 With One-touch fitting Thread type ASP Brass parts are all electroless nickel plated.
(mm)Connection threadsModel Elbow typeUniversal type Meter-outMeter-inMeter-outMeter-in8R 1/8AS2201FG-01-08AS2211FG-01-08AS2301FG-01-08AS2311FG-01-08
(mm)Connection threadsModel Elbow typeUniversal type Meter-outMeter-inMeter-outMeter-in8R 1/8AS2201FG-01-08AS2211FG-01-08AS2301FG-01-08AS2311FG-01-08
6 Body size If more than one option is required, write option part numbers in the order of K, N. 1 2 3 4 M5 standard 01, 02 standard 03 standard 04 standard Tube size (1) 4 6 8 10 12 04 06 08 10 12 Electroless nickel plated (3) Brass PBT PBT/Stainless steel NBR NBR NBR NBR NBR NBR NBR/Stainless steel Electroless nickel plated Elbow type Control method Meter-out Meter-in 0 With One-touch fitting
Series VX Solenoid Coil Assembly How to Order VX021 C 001 01 B Rated voltage (1) VX solenoid coil assembly 02 =+4 7> 01 =+4 7> Electrical option Application 03 =+4 7> Nil # 04 =+4 7> > -/& S 5 % * ,* -05 ( ! 001 # ) # ) #' ) L 5 % ) / *% 06 ! ' 002 003 Z 5 % *%+ * ,* -07 ( =+4 7> 08 (?
E 03 05 07 09 't't 5132" 1l4', 5/16' 3t8" 1/2" 6mm 8mm H , T , U , X , N 1 3 06 08 t0 1 2 1 6 32 i10-32 UNF Thread 3 5 I l t N P r H ' L . W , r .
Model GS40-M5 GS40-01 GS40-02 AV Air/Inert gas Fluid AU 3% F.S.
w Body size 20 30 40 50 60 AFF Nominal filtration rating: 1 m V V V V V Water droplet removal ratio: 99% AM Nominal filtration rating: 0.1 m V V V V V Oil mist concentration on the outlet side: 1 mg/m3 q Filter type AMD Nominal filtration rating: 0.01 m V V V V V Oil mist concentration on the outlet side: 0.1 mg/m3 + e Thread type Nil Rc V V V V V N*1 NPT V V V V V F*2 G V V V V V + 01
Filter plate 2 Series FN1 Flow Characteristics (Initial Value) Test fluid: Potable water Liquid temperature: 17 to 20C (room temperature) Test method: Per P/A test method (sanitary test stand) Element length 250mm: FN111-10-S Element length 500mm: FN112-10-S .1 .1 .05 .05 FN111-10-S005 (5m) Pressure loss (MPa) Pressure loss (MPa) FN112-10-S005 (5m) FN111-10-S020 (20m) .01 .01 FN112-10-S020
VH*-OMX0068-A PRODUCT NAME Pressure Relief 3 Port Valve with Locking Holes MODEL / Series / Product Number VHS20-(F,N)01~(F,N)02(-R,Z)-D VHS30-(F,N)02~(F,N)03(-R,Z)-D VHS40-(F,N)02~(F,N)04(-R,Z)-D Contents Page 1. Safety Instructions 1~5 2. Application 6 3. Specifications 6 4. How to Order 7~8 5. Construction / Parts List 9 6.
Solenoid Direction: Opposite side of A port (A port bottom ported for Type 40), Type: 42 (A Port Side Ported; 42S: Solenoids on the Same Side of A Port), Stations: 01, Port Size: 01 (Rc 1/8), Thread: T (NPTF)
Solenoid Direction: Opposite side of A port (A port bottom ported for Type 40), Type: 42 (A Port Side Ported; 42S: Solenoids on the Same Side of A Port), Stations: 01, Port Size: 01 (Rc 1/8)
Solenoid Direction: Opposite side of A port (A port bottom ported for Type 40), Type: 42 (A Port Side Ported; 42S: Solenoids on the Same Side of A Port), Stations: 01, Port Size: 01 (Rc 1/8), Thread: N (NPT)