29.5 18.5 55.3 23 9.8 49.3 R 1/4 1.2 19 21.8 AS321F-02-10SD AS321F-N02-07SD 1/4" 13.2 27.8 39.3 17 10 18.5 43.3 21 31.8 AS321F-02-12SD AS321F-N02-09SD NPT 1/4 19 23 9.8 21.8 55.3 1.2 49.3 5/16" 15.2 29.5 41 18.5 12 20.9 44.3 32.8 22 AS321F-03-06SD AS321F-N02-11SD 17.9 31.8 43.3 21 6 3/8" 12.8 39.3 27.8 17 AS321F-03-08SD AS321F-N03-07SD 8 15.2 41 29.5 18.5 1/4" 13.2 27.8 39.3 17 53.7 23 9.8
Built-in pulsation attenuator Process Pump Series PAX1000 Automatically operated type (internal switching type) Built-in solenoid valve/ Air operated type (external switching type) Prevents spraying of discharge and foaming in tank Built-in pulsation attenuator saves space and makes separate piping unnecessary A solenoid valve operated pump that fits in the palm of the hand 60 x 60 x 41
L4 Note) Weight (g) 5 5.5 6.5 8.5 9.5 19 22 35 38 52 86 95 Model Applicable tubing O.D. d AS1002F-01 AS1002F-03 AS1002F-07 AS2002F-03 AS2002F-07 AS2052F-07 AS2052F-09 AS3002F-07 AS3002F-09 AS3002F-11 AS4002F-11 AS4002F-13 MIN.
Symbol Position detector arms Switch bracket Positioning angle For the applicable auto switch model, refer to the table below. a b c d 10 11 12 13 14 15 20 23 25 180 X X X X X Data X X X X X X X 90 b d X Table position detector arm X X X X X X X a X Switch mounting bracket X X Cylinder Unit/Applicable Auto Switch Load voltage Lead wire length (m) Auto switch model Electrical entry Wiring
13 90 3.2 Note 1) The dimension of B is the length when the filter regulator knob is unlocked.
13 Rc 1/4 (G1/4, NPT1/4) (Finger opening port) 16 22 5 6.45 MHW2-50D1 6 Right angle finger type 78 37 24 30 39 12 58 85 52 4 x M10 x 1.5 through (Thread for mounting attachment) 718 MHY2/MHW2 Series Auto Switch Installation Examples and Mounting Positions Various auto switch applications are possible through different combinations of auto switch quantities and detecting positions.
9 Rod seal NBR Basic (B) CM2QB Bore size Stroke (mm) Stroke range 1 to 300 1 to 300 1 to 300 1 to 300 S 65 65 67 91 N 15 15 15 21.5 Bore A 18 22 22 24 B2 26 32 32 41 D 8 10 12 14 H2 8 8 8 10 I 28 33.5 37.5 46.5 ZZ 119 123 125 157 NA 24 30 34.5 42.5 AL 15.5 19.5 19.5 21 E F 13 13 13 16 K 5 5.5 5.5 7 NN M20 X 1.5 M26 X 1.5 M26 X 1.5 M32 X 2 B1 13 17 17 22 G 8 8 8 11 MM M8 X 1.25 P 1/8 1/8 1
22 19.5 17 32 10 13 8 45 6 8 33.5 5.5 15 30 M26 x 1.5 1/8 62 120 M10 x 1.25 26 22 19.5 17 32 12 13 8 45 6 8 37.5 5.5 15 34.5 M26 x 1.5 1/8 64 122 M10 x 1.25 26 24 21 22 41 14 16 11 50 8 10 46.5 7 21.5 42.5 M32 x 2 1/4 88 154 32 M14 x 1.5 (mm) Boss-cut ZZ Bore size (mm) 20 25 32 40 103 107 109 138 10
Contact protection box OUT(+) Brown [Red] Lead wire length: 0.5m 7 7 6 7 8 8 Resistor Reed switch Lead wire length: 3m 35 35 30 35 41 41 Zener diode CD-P11 OUT() Blue [Black] Contact Protection Box CD-P12 Blue [Black] D-A96(V) Contact protection box internal circuits Type D-A9 switches do not have built-in contact protection circuits.
If a moment or torque directly acts on the cylinder, it will lead to reduced service life or damage to machinery. 7 3 Position Cylinder Series RZQ Construction 13 24 21 3 2 1 6 4 8 7 10 19 22 20 12 23 11 9 5 23 18 14 16 17 15 22 Parts list No. 1 2 3 4 5 6 7 8 9 10 11 12 No. 13 14 15 16 17 18 19 20 21 22 23 24 Note Note Description Material Description Material Hard anodized Aluminum alloy
Withstand voltage Z Zero clear (function) Adjusts the displayed pressure value to "0". 13 - NO. ZQ-OM01501 Electrical Connection Wiring Connection Connections should only be made with the power supply turned off. Use separate routes for the Pressure switch wiring and any power or high voltage wiring. Otherwise, malfunction may result due to noise.
.2 OFF ON No.1 OFF No.3 No.4 No.5 No.6 44 - No.7 Yes No No.8 No.8 No.9 No.10 No.11 No.12 No.13 No.14 No.15 45 - No.
(N speci{icaltons) 1 F Hffi l\,4etric lnch l\4ark ng rs eleclroess nicke plared prov ded as standard (N specificatron) Also Available: AS-FG Stainless steel Metal elbow type wiih One.touch Fittings Elbow Type thrad f f i H # ' Noi available on AS12oo [,13 and AS1400-['13 Hffi o a a a a a a a a a a a o a a a a a a a a a a a a a a a a a a . _9q_"9i"1 Tube Sel Design Large T[rbe Insertion Depth
Apply a wrench Width across flats of attachment 3/8 24 mm 1/2 28 mm 3/4 35 mm 1 41 mm Moment load Turn the piping OK Flexible piping Vibration Refer to the tightening torque in the right table for connecting steel piping. Torque lower than the value in the table leads to fluid leakage. For mounting the fittings on the market, refer to the torque specified for each.
13 J 5.4 6.5 8.5 8.5 11 11 H 22 23 26 25 35 35 G 27 40 54 54 66 66 F 30 41 50 50 70 70 E 18 16 17 14 23 23 M5 x 0.8 1/8, 1/4 1/4, 3/8 1/4, 3/8, 1/2 3/4 3/4, 1 1 AF10 AF20 AF30 AF40 AF40-06 AF50 AF60 Optional specification Model With barb fitting B 137 173 177 253 266 With drain guide B 136 172 176 252 265 Metal bowl B 66 97 142 178 182 258 271 Metal bowl with level gauge B 162
MRHQ20 MRHQ25 Model Fluid Air Rotary section 0.25 to 0.7MPa (36 to 101psi) 0.25 to 1.0MPa (36 to 145psi) Operating pressure Double acting 0.1 to 0.6MPa (14 to 87psi) 0.1 to 0.7MPa (14 to 101psi) Gripper section Single acting 0.25 to 0.6MPa (36 to 87psi) 0.25 to 0.7MPa (36 to 101psi) Rotation angle 9010, 18010 Gripper action Double acting, Single acting Ambient and fluid temperature 5 to 60C (41
In common Type 60 SY3 60 Cassette type Individual wiring SY5 60 P. 59 R Size and weight reduced by eliminating the manifold base + + P SY7 60 Type 41 Compact bar stock type Individual wiring SY3 40 SY5 40 + + + + P. 79 The base mounting facilitates maintenance after valves are changed.
90 45 8 22 107 70 74.5 103 74.5 48 84 26 1/4, 3/8 VCB41 M5 23 25 36 17 13.5 41 94 50 8 30 111.5 70 78.5 103 78.5 48 88 26 1/2 M5 28.2 30 36 17 17.5 41 102 60 8 35 119 70 86.5 103 86.5 48 96 26 3/4 4 Direct Operated 2 Port for Heated Water Series VCB Model Selection VCB (for heated water) 2 port solenoid valve Class Orifice size mm Model Material Port size Body Seal 4 3 2 7 5 10 1/8 (6A)
90 45 8 22 107 70 74.5 103 74.5 48 84 26 1/4, 3/8 VCB41 M5 23 25 36 17 13.5 41 94 50 8 30 111.5 70 78.5 103 78.5 48 88 26 1/2 M5 28.2 30 36 17 17.5 41 102 60 8 35 119 70 86.5 103 86.5 48 96 26 3/4 4 Series VCB Model Selection VCB (for heated water) 2 port solenoid valve Class Orifice size mm Model Material Port size Body Seal 4 3 2 7 5 10 1/8 (6A) 2 1/4 (8A) VCB (for heated water) 2 port