operating current 50/60Hz 5 A 8.4 / 9.1 Rated power consumption 50/60Hz5 kW (kVA) 4.4 / 5.6 (5.8 / 6.3) Sound level (Front 1m / Height 1m)5 dB(A) 75 Alarm cord list label 2pc.
5 10 15 20 25 30 kPa Pressure loss [kPa] Pressure loss [kPa] 750 kPa 50 kPa 30 0 kPa 0 kPa 20 30 kPa 50 kPa 70 kPa 750 kPa 350 kPa 10 70 kPa 350 kPa 00 10 20 30 40 50 Flow [L/min] Flow [L/min] PF2M711(-L) 100 L/min PF2M721(-L) 200 L/min 40 90 80 70 60 50 40 30 20 10 00 50 100 150 200 Pressure loss [kPa] Pressure loss [kPa] 750 kPa 30 30 kPa 0 kPa 0 kPa 20 750 kPa 30 kPa 50 kPa 50 kPa 350
K Note 2) Negative common N Note 3) Coil voltage CE-compliant External pilot R Note 3) Note 5) 1 2 3 4 5 6 100 VAC (50/60 Hz) 200 VAC (50/60 Hz) 110 VAC (50/60 Hz) 220 VAC (50/60 Hz) 24 VDC 12 VDC Note 1) Refer to page 381 for power consumption of AC type.
220 VAC 50/60 Hz [230 VAC 50/60 Hz] 4 For type W, only DC voltage is available.
Double acting, Single rod Double acting, Double rod CE1 50 63 10, 15, 20, 25, 30, 35 40, 45, 50, 75, 100 CE2 80 100 ML2B C J G5-S CHQB CHQWB CV MVGQ CC For details, refer to the catalog CAT. E111.
Double acting, Single rod Double acting, Double rod CE1 50 63 10, 15, 20, 25, 30, 35 40, 45, 50, 75, 100 CE2 80 100 ML2B C J G5-S CHQB CHQWB CV MVGQ CC For details, refer to the catalog CAT. E111.
page 12 for dimensions. 200, 220, 230, 240 VAC (50 Hz), 200 to 260V (60 Hz) 2 100 VAC (50 Hz) 100 to 110 VAC (60 Hz) Single phase 380, 400, 415 VAC (50 Hz), 380 to 420V (60 Hz) 3 Compound 420, 440, 480 VAC (50 Hz), 420 to 520V (60 Hz) 4 Please refer to page 11 for dimensions.
Note) 2 position single 1 2 Note) 100 VAC (50/60 Hz) 200 VAC (50/60 Hz) 110 VAC (50/60 Hz) 220 VAC (50/60 Hz) 24 VDC 12 VDC G: Grommet C kit single only.
50 5 0 Z X Mass and center of gravity of the load 25 Center of gravity 50 Load no.
[ CoL] Display colour (OUT2) [1SoG] ON: Green, OFF: Red (OUT2) Page 50 With temperature sensor [ oUt2] Output mode (OUT2) [ tHYS] Temperature hysteresis Page 46 [ 2ot] Switch operation (OUT2) [ 2_n] Reverse output Page 46 [ tn_2] Set value (OUT2) 50% of maximum rated flow [ 50] 50 oC (for all ranges) Page 50 [ tH_2] Hysteresis (OUT2) 0% of maximum rated flow [ 5] 5 oC (for all ranges) Page
50 50 50 50 50 Trigger LV 50 50 50 50 50 50 Pushing speed 20 30 20 30 20 30 Moving force 100 100 100 100 100 100 Area1 0.00 0.00 0.00 0.00 0.00 0.00 Area2 0.00 0.00 0.00 0.00 0.00 0.00 In position 0.50 0.50 0.50 0.50 0.50 0.50 102 - LER Basic parameter default Model LER10K LER10J LER30K LER30J LER50K LER50J Gear Ratio [] 8 12 8 12 7.5 12 Controller ID 1 1 1 IO pattern 1 1 1 Acceleration/
230 V (50 Hz) Three-phase 200 V (50 Hz) Three-phase 200/220 V (60 Hz) IDU37E R1 1/2 37 215.4 201.3 IDU55E 55 346.0 296.6 R2 IDU75E 75 441.4 388.4 Refer to the separate catalog.
Bore size/Stroke (mm) 6 10, 20, 30, 40, 50 8 10, 20, 30, 40, 50, 75 12 10, 20, 30, 40, 50, 75, 100 16 10, 20, 30, 40, 50, 75, 100, 125 20 10, 20, 30, 40, 50, 75, 100, 125, 150 25 10, 20, 30, 40, 50, 75, 100, 125, 150 Adjuster option Nil Without adjuster Functional option AS Extension end adjuster AT Retraction end adjuster Standard Nil A Both ends adjuster P Note) Axial piping CS Extension
Extension end 8 10, 20, 30, 40, 50, 75 Rubber stopper Retraction end Both ends 12 10, 20, 30, 40, 50, 75, 100 16 10, 20, 30, 40, 50, 75, 100, 125 20 10, 20, 30, 40, 50, 75, 100, 125, 150 25 10, 20, 30, 40, 50, 75, 100, 125, 150 Functional option Standard Nil P Note 1) Axial piping Note 1) The combination of axial piping and both ends adjusters or retraction end adjusters is not available.
buffer, axial piping 6 Centralized adjuster 7 Centralized adjuster (Symmetric) 8 Buffer, Centralized adjuster 9 Buffer, Centralized adjuster (Symmetric) Nil 2 S 1 n n Port Switch mounting groove Port Switch mounting groove 8 10, 20, 30, 40, 50, 75 12 10, 20, 30, 40, 50, 75, 100 For details, refer to the next page. i Made to order 16 10, 20, 30, 40, 50, 75, 100, 125 Port Switch mounting groove
to the VX series) (as compared to the VX series) Single valve volume: Single valve volume: Reduced by Reduced by 75% 75% (VDW20) (VDW20) Manifold length: Manifold length: Reduced by Reduced by 18% 18% (VDW30, 7 stations) (VDW30, 7 stations) Lightweight Lightweight (as compared to the VX series) (as compared to the VX series) 100 g: Reduced approx. by 100 g: Reduced approx. by 50% 50% (
40 30 20 10 0 100 90 80 70 60 50 40 30 20 10 0 Vacuum pressure [kPa] Vacuum pressure [kPa] ZL3H ZL3H04P ZL3M ZL3M04P Suction flow rate [L/min (ANR)] 100 50 200 150 300 250 350 0 Suction flow rate [L/min (ANR)] 100 50 200 150 300 250 350 0 23 Multistage Ejector ZL3/ZL6 Series Flow Rate Characteristics (Representative value) ZL6M (04P) Supply pressure: 0.35 MPa/0.37 MPa (With valve) ZL6H (
XC57 With floating joint 2 6 (1/4") Minimum Operating Pressure 0 25 50 75 100 0 25 50 75 100 Supply pressure (PSI) Supply pressure (PSI) 50, 60 30 600 23 23 23 23 22 25 Minimum operating pressure (PSI) 20 500 20 17 17 17 Theoretical thrust (Ibf) 63 (2-1/2") 15 400 10 300 5 200 0 6 (1/4") 10 (3/8") 50 (2") 15 (5/8") 20 (3/4") 25 (1") 32 (1-1/2") 40 (1-1/2") 50 (2") 63 (2-1/2") 100 Bore size
Hz), 3-phase 200 to 230 VAC (60 Hz) Allowable voltage range 10% (No continuous voltage fluctuation) Earth leakage breaker Rated current [A] 30 40 50 Electrical system Sensitivity current [mA] 30 Rated operating current4 [A] 17 32 41 Rated power consumption4 [kW (kVA)] 5.4 (5.9) 10.5 (11.0) 13.1 (14.2) Noise level (Front 1 m/Height 1 m)4 [dB(A)] 75 75 71 Accessories Operation Manual (for
Series ISE70/75/75H 2-Color Display Digital Pressure Switch NPN/PNP open collector 2 outputs added. Cut-to-zero display function added.