, 75, 100 54 M6 x 1.0 42 12 12(11.8) 45 8.5 M6 x 1.0 7 60 4.5 10 12 34 5.5 9 23 10 49.5 7 30 10 to 50, 75, 100 60.5 M6 x 1.0 48.5 13 16(15.8) 52 8.5 M8 x 1.25 7 69 5 14 12 40 5.5 9 26 10 57 10 40 10 to 50, 75, 100 62 M8 x 1.25 50 13 16(15.8) 64 12 M8 x 1.25 8 86 7 14 12 50 6.6 11 26 14 71 10 Note) Figures in ( ) are the dimensions for applying a wrench.
Maximum piston speed: 500 mm/s It can be used at 50 to 500 mm/s provided that it is within the allowable kinetic energy range.
Q + Stroke (NA) Cylinder form 12 16 (mm) d Bore size (mm) Standard stroke (mm) A B C E G GP H HA HG HN HP HT J JK L LD Slide Ball bushing 12 15, 25 8 4 16 25 7.5 50 34 6 14.5 34 33 18 M5 x 0.8 9.5 68 4.3 8.5 10 16 15, 25 9.5 5 18 29 6.5 65 40 6.5 16 39.5 39 21 M6 x 1 9.5 75 5.2 7.5 12 20 25, 50 11 6.5 25 36 8.5 80 46 9 18 44.1 45 24 M8 x 1.25 10 86 6.9 9.5 16 25 25, 50 11 6.5 25 40 8.5 90
Bore 1/32 1/16 1/8 1/4 3/8 1/2 3/4 1 1 6 15 37 1-1/8 5 12 28 85 1-1/2 3 7 16 50 2 4 9 28 70 2-1/2 6 18 45 72 3 4 12 30 48 3-1/4 3 10 24 37 79 4 7 17 28 60 5 4 11 18 40 82 6 3 7 12 26 55 8 4 7 15 32 10 4 9 20 12 3 6 14 NOTE: These values are an approximate speed, under average conditions, where the force required is 50% of available 80-100 PSI inlet pressure, the directional valve internal
Bore 1/32 1/16 1/8 1/4 3/8 1/2 3/4 1 1 6 15 37 1-1/8 5 12 28 85 1-1/2 3 7 16 50 2 4 9 28 70 2-1/2 6 18 45 72 3 4 12 30 48 3-1/4 3 10 24 37 79 4 7 17 28 60 5 4 11 18 40 82 6 3 7 12 26 55 8 4 7 15 32 10 4 9 20 12 3 6 14 NOTE: These values are an approximate speed, under average conditions, where the force required is 50% of available 80-100 PSI inlet pressure, the directional valve internal
/60 Hz) 200 VAC (50/60 Hz) 110 VAC (50/60 Hz) 220 VAC (50/60 Hz) 24 VDC 12 VDC Note 1) The code is L for elbow piping for all manifold stations.
13.5 Electrical entry Conduit terminal Conduit Faston Port size P Model Q R Q R Q R S T 71 71 73.5 73.5 3 A 4 B 5 C 6 D VXZ2 VXZ2 VXZ2 VXZ2 1/4, 3/8 1/2 3/4 1 50 50 52.5 52.5 57.5 (64) 62.5 (68.5) 70.5 (77) 73.5 (79) 25.5 25.5 28 28 63.5 (70) 68.5 (74.5) 76.5 (82.5) 79.5 (85) 100 (106.5) 108 (114.5) 119 (126) 125 (131) 102 102 104.5 104.5 57.5 (64) 62.5 (68.5) 70.5 (77) 73.5 (79) ( ) are
Q + Stroke (NA) Cylinder form 12 16 d Bore size (mm) Standard stroke (mm) A B C E G GP H HA HG HN HP HT J JK L LD Slide Ball bushing 12 15, 25 8 4 16 25 7.5 50 34 6 14.5 34 33 18 M5 x 0.8 9.5 68 4.3 8.5 10 16 15, 25 9.5 5 18 29 6.5 65 40 6.5 16 39.5 39 21 M6 x 1 9.5 75 5.2 7.5 12 20 25, 50 11 6.5 25 36 8.5 80 46 9 18 44.1 45 24 M8 x 1.25 10 86 6.9 9.5 16 25 25, 50 11 6.5 25 40 8.5 90 54 9
Q+Stroke (NA) Cylinder form 12 16 (mm) d Bore size (mm) Standard stroke (mm) A B C E G GP H HA HG HN HP HT J JK L LD Slide Ball bushing 12 15, 25 8 4 16 25 7.5 50 34 6 14.5 34 33 18 M5 X 0.8 9.5 68 4.3 8.5 10 16 15, 25 9.5 5 18 29 6.5 65 40 6.5 16 39.5 39 21 M6 X 1 9.5 75 5.2 7.5 12 20 25, 50 11 6.5 25 36 8.5 80 46 9 18 44.1 45 24 M8 X 1.25 10 86 6.9 9.5 16 25 25, 50 11 6.5 25 40 8.5 90 54
, 50 Rod end thread Female thread 32, 40 5, 10, 15, 20, 25, 30, 35, 40, 45, 50, 75, 100 Rod end thread tolerance JIS class 2 50 to 100 10, 15, 20, 25, 30, 35, 40, 45, 50, 75, 100 +1.0 0 Stroke length tolerance When stroke exceeds the standard range, refer to page 7-6-121.
-XC6 -XC8 -XC9 -XC10 -XC11 Adjustable stroke cylinder/Adjustable extension type Air-hydro type (mm) Adjustable stroke cylinder/Adjustable retraction type Bore size 20, 25 32, 40 50, 63, 80, 100 Standard stroke Dual stroke cylinder/Double rod 5, 10, 15, 20, 25, 30, 35, 40, 45, 50 5, 10, 15, 20, 25, 30, 35, 40, 45, 50, 75, 100 10, 15, 20, 25, 30, 35, 40, 45, 50, 75, 100 Dual stroke cylinder
When using a feedback sensor at higher than 50 mm, refer to the graphs below.
PF3A703H (For 3000 L/min) PF3A706H (For 6000 L/min) PF3A712H (For 12000 L/min) 74 No.PF-OMU0002-D Dimensions Symbol Models A B D E F H K L N PF3A703H 130 45 79.1 55.3 22.5 25 35 60 30 4 x M4 x 0.7 depth 7 PF3A706H 170 60 94.1 70.3 30 68 45 80 40 4 x M5 x 0.8 depth 8 PF3A712H 200 70 104.1 80.3 35 85 50 100 50 4 x M6 x 1.0 depth 9 75 No.PF-OMU0002-D Lead wire with M12 connector (ZS-37-A) Pin
(Value in the initial state) Vibration resistance: No malfunction occurred in one sweep test between 45 and 2000 Hz. Test was performed to axis and right angle directions of the main valve when pilot signal is ON and OFF .
Dimensions 10.5 10.5 178 (3.6) 1 C H C H R S 16.7 OUT IN AX/ 140A 28.3 0 45 4.1 53.5 5.1 (3.7) 55 1 1F 16 D 4 0 2 3 5 6 7 8 9 A B C E F 10 11 12 13 14 15 17 18 19 1A 1B 1C 1D 1E + + + + + + + + + + + + + + + + 4.5 5 5 Refer to page 50 in CAT.E02-20 for the junction cable part number.
24.2 41.5 (Mounting hole) 24.2 Bracket (Mounting groove for M5 thread) 2-R 2.7 (PA port) Rc 1/8 PA 45.9 40.5 45 45 28 4.5 1.6 41.6 22 60 50 9 90.9 (Piping port) Rc 1/4, 3/8 30.7 26.1 3.5 7 1(P) 3(R) (Bottom existing hole) M5 x 0.8 through hole 77.2 5-5-17 6 Series VPA300/500/700 Dimensions A B Base mounted: VPA544(A port) Rc 1/4, 3/8 13.5 91.4 84.4 (PA port) Rc 1/8 57 47 13.5 (PA port) Rc
Services 15 Sebaai Street, Miami 21411 Alexandria, Egypt TEL: 3-548-50-34 FAX: 3-548-50-34 PAKISTAN (Distributor) Jubilee Corporation First Floor Mercantile Centre, Newton Road Near Boulton Market P.O.
Refer to back page 50 for Safety Instructions, pages 543 to 546 for Flow Control Equipment Precautions, and pages 573 to 575 for Specific Product Precautions.
Table 7-1 Water Quality Standards Substance Facility water Circulating water spec. spec. pH (25C) 6.5 to 8.2 6.0 to 8.0 Electrical conductivity (25C) (s/cm) 100 to 800 0.5 to 300 Chloride ion (mgCl-/L) Max. 200 Max.50 Sulfate ion (mgSO42-/L) Max. 200 Max.50 Acid consumption (pH4.8) (mgCaCO3/L) Max. 100 Max.50 Total hardness (mgCaCO3/L) Max. 200 Max.70 Calcium hardness (mgCaCO3/L) Max. 150
Applicable cylinder ML2B25 ML2B32 ML2B40 MY-S25A 35 50 8 5 9.5 5.5 M6 x 1 B MY-S32A 45 64 11.7 6 11 6.6 M8 x 1.25 B Guide for Side Support Application For long stroke operation, the cylinder tube may be deflected depending on its own weight and the load. In such a case, use a side support in the middle section.