45 Stroke 134 135 63 67 60 Stroke 60 Stroke Weight Weight 155 154 75 Stroke 75 Stroke CJ1 198 192 100 Stroke 100 Stroke CJP 234 226 125 Stroke 125 Stroke 260 250 150 Stroke 150 Stroke CJ2 This weight includes weight of rod end nut.
Table 7.1-1 Quality criteria for clean water (tap water) Item Unit Criterion Circulating fluid Facility water pH (at 25 oC) 6.0 to 8.0 6.5 to 8.2 Electric conductance (at 25 oC) [S/cm] 100 to 300 100 to 800 Chloride ion [mg/L] 50 or less 200 or less Standard Sulphate ion [mg/L] 50 or less 200 or less item Acid consumption (at pH 4.8) [mg/L] 50 or less 100 or less Total hardness [mg/L] 70
CQ-M3 x 70 L 40 75 CQ-M3 x 75 L 45 80 CQ-M3 x 80 L 50 85 CQ-M3 x 85 L 20 5.5 D C 5 45 CQ-M3 x 45 L 10 50 CQ-M3 x 50 L 15 55 CQ-M3 x 55 L 20 60 CQ-M3 x 60 L 25 65 CQ-M3 x 65 L 30 70 CQ-M3 x 70 L 35 75 CQ-M3 x 75 L 40 80 CQ-M3 x 80 L 45 85 CQ-M3 x 85 L 50 90 CQ-M3 x 90 L 25 8 6 MXZ Series Dimensions: MXZ12 MXZ12Standard (Pilot port location: Front) 4 x 6 4 x M3 x 0.5 depth 5 17 14 14 2 x 3.4
Output deviation factor (% F.S.) 20 0.5 30 Set pressure (kPa) 40 0 50 60 0.5 70 80 90 1.0 100 80 60 40 20 50 100 150 Flow rate (l/min(ANR)) VAC side pressure (Supply pressure) (kPa) 14-8-31 32 Dimensions ITV2090 Note) Do not attempt to rotate the cable connector, as it does not turn.
Station 20 372 359 353 340 3 83 70 81 68 6 134 121 129 116 8 168 155 161 148 10 202 189 193 180 Station 2 66 53 65 52 4 100 87 97 84 5 117 104 113 100 7 151 138 145 132 9 185 172 177 164 11 219 206 209 196 12 236 223 225 212 13 253 240 241 228 14 270 257 257 244 15 287 274 273 260 16 304 291 289 276 17 321 308 305 292 18 338 325 321 308 19 355 342 337 324 Station n L1 L2 L1 L2 A, B port size
kPa 27 to 80 kPa 4.5 to 28 VDC (ZSM1-115) to 100 VDC to 100 VAC 24 to 125 VDC 100 to 250 VAC 24 to 220 VDC 100 to 550 VAC Voltage 100 VAC/DC or less (ZSM1-121) Repeatability 0.05 MPa 0.05 MPa 3% F .S. 3% F.S. 3% F.S. 3% F.S. 10% F.S. 15 kPa or less (ZSM1-115) 0.02 to 0.35 MPa (Without pointer scale) 0.03 to 0.4 MPa (Without pointer scale) Hysteresis (Calibration range of ISG) 0.08 MPa or
Applicable cylinder series CKP140-100 63 50 40 CKP140-125 BK1T-040 D-P4DWSC D-P4DWSE D-P4DWL/Z CKP140-150 Series CKG1 CKG140-50 CKG150-50/CKP150-50 CKG163-50/CKP163-50 CKG140-75 CKG150-75/CKP150-75 CKG163-75/CKP163-75 CKG140-100 CKG150-100/CKP150-100 CKG163-100/CKP163-100 CKG40-R050 Series CKP1 BAP1T-040 D-P79WSE D-P74L/Z Series CKG140/50/ 63 CKG40-R075 CKG40-R100 Series CKP150/63 CKG140-
psig (0.69 MPa) 40 psig (0.28 MPa) Inlet pressure: 80 psig (0.55 MPa) 20 psig (0.14 MPa) AZ1500 2000 to 3000 psig (13.8 to 20.7 MPa) 500 psgi (3.4 MPa) Inlet pressure: 1000 psig (6.9 MPa) 200 psig (1.4 MPa) 50 0.34 0.69 100 0.62 90 80 40 0.28 0.55 Delivery pressure (slpm) Delivery pressure (MPa) Delivery pressure (MPa) Delivery pressure (psig) 0.48 70 0.41 60 30 0.21 0.34 50 0.28 20 0.14
100 120 120 Min. speed [mm/s] (Independent and 5 5 5 5 5 5 interpolation) Min. speed [mm/s] 8 8 8 9 9 9 (Speed tuning control) 112 No.SFOD-OMT0010-B Model LEHF10 LEHF20 LEHF32 LEHF40 Lead symbol K Lead [mm] 40/15 50/15 70/16 70/16 (2.667) (3.333) (4.375) (4.375) Max. speed [mm/s] 80 100 100 100 Min. speed [mm/s] 5 5 5 5 (Independent and interpolation) Min. speed [mm/s] 7 8 8 8 (Speed tuning
CKGA80, 100/CKPA80, 100/With Magnetic Field Resistant Auto Switch (Rod Mounting Type) 1 P3DWASC CK G A 80 Y Built-in standard magnet type with magnetic field resistant auto switch 100 Built-in strong magnet type with magnetic field resistant auto switch 100 P79WSE CK P A 80 Y Built-in standard magnet Number of auto switches Nil S 2 pcs. 1 pc.
100 120 120 [mm/s] 5 5 5 5 5 5 () [mm/s] 8 8 8 9 9 9 () 110 No.SFOD-OMT0009CN-B LEHF10 LEHF20 LEHF32 LEHF40 K [mm] 40/15 50/15 70/16 70/16 (2.667) (3.333) (4.375) (4.375) [mm/s] 80 100 100 100 [mm/s] 5 5 5 5 () [mm/s] 7 8 8 8 () LEHS10 LEHS20 LEHS32 LEHS40 K [mm] 255/76 235/56 235/40 235/40 (3.355) (4.196) (5.875) (5.875) [mm/s] 70 80 100 120 [mm/s] 5 5 5 5 () [mm/s] 8 8 9 9 () 111
Table 8-1 Quality criteria for clean water (tap water) Item Unit Criterion Circulating fluid Facility water pH (at 25 oC) 6.0 to 8.0 6.5 to 8.2 Electric conductance (at 25 oC) [S/cm] 100 to 300 100 to 800 Chloride ion [mg/L] 50 or less 200 or less Standard Sulfuric acid ion [mg/L] 50 or less 200 or less item Acid consumption (at pH 4.8) [mg/L] 50 or less 100 or less Total hardness [mg/L]
(s3) 6.69 (170) 2.O5 (.521 2.da (66) (r78) 1.57 (40) 402 (102) 3.07 {78) 0.98 (25) 2.05 (52) 0.55 ( 1 4 ) 3.94 {100) 1.50 (38) \62) 1.34 (35) o.67 ( 7 ) M22x1.5 (3?)
Adjustable from 0.5 to 2 mm 70 70 Shim Mounting tap: M10 x 1.5 Pin hole: 8H7 Mounting tap: M10 x 1.5 Pin hole: 8H7 66 66 One 1 mm and two 0.5 mm shims are attached.
speed should be 100 to 200mm per second.
water for welding gun Main line flow control The accumulated pulse output function (100 l/pulse) enables remote monitoring of accumulated flow. 100 l/pulse M/C A COM COM COM B DC12V GND F.G.
107 1/4, 3/8 VCW41 30 50 94 41 13.5 17 36 25 23 M5 8 26 66.5 48 64.5 62 62 50.5 103 64.5 70 111.5 1/2 35 60 102 41 17.5 17 36 30 28.2 M5 8 26 70 48 68 62 65.5 50.5 103 68 70 119 3/4 17-2-55 8 Series VCW Dimensions (N.O.)
Note Description No. 02 C8 C10 SY760-1 Valve Includes 3pcs. of bushing assembly (SY7000-70-1A) U side Ports P, R: With 12 One-touch fitting Includes 3pcs. of bushing assembly (SY7000-70-1A) SY7000-75-1A 2 Supply/Exhaust block assembly Common for U & D sides (bushing assembly: SY7000-70-1A not included) SY7000-56-1A 3 End block assembly SY7000-70-1A 4 Bushing assembly Refer to page 7.
16 16 0.2 0.05 0.1 0.2 0.1 0.05 1500 1000 500 400 300 200 100 1500 1000 500 400 300 200 100 1500 1000 500 400 300 200 100 MY3B max.