Series 12 16 20 25 32 40 50 63 80 100 125 CQ2-Z 3.5 4.5 4.5 5.0 5.5 5.0 5.0 6.0 6.0 6.0 7.5 CQM 3.5 4.0 4.5 4.5 5.0 5.0 5.0 6.0 5.5 6.0 RZQ 5.0 5.0 5.0 5.5 MK-Z 3.0 3.5 3.5 4.0 4.5 4.0 4.5 4.5 MGP-Z 3.5 5.0 4.5 5.0 5.5 5.5 5.5 5.5 5.5 5.5 MGZ 2 3.5 4.5 4.5 4.5 5.0 5.5 5.5 Tube I.D.
MHS2 -20D MHS2 -25D MHS2 -32D MHS2 -40D MHS2 -50D MHS2 -63D mm 16 20 25 32 40 50 63 MPa 0.20.6 0.10.6 -1060 mm 0.01 c.p.m. 120 60 21 37 63 111 177 280 502 1 N 23 42 71 123 195 306 537 mm 4 4 6 8 8 12 16 g 58 96 134 265 345 515 952 1) 1625 L=20mm 3263 L=30mm 0.5MPa MHS3 16D MHS320D MHS325D MHS332D MHS340D MHS350D MHS363D MHS380D MHS3100D MHS3125D MHS3mm 16 20 25 32 40 50 63 80 100 125
USB 7. 106 No.SFOD-OMT0009CN-B 7. 7. 4. ( EMG ) 4. 107 No.SFOD-OMT0009CN-B 1. 1.1 LEY/LEYG LEY16/LEYG16 LEY25/LEYG25 LEY32/LEYG32 LEY40/LEYG40 A B C A B C A B C A B C [mm] 10 5 2.5 12 6 3 16 8 4 16 8 4 [mm] 300 300 300 400 400 400 500 500 500 500 500 500 [mm/s] 500 250 125 500 250 125 500 250 125 300 150 75 [mm/s] 15 8 4 18 9 5 24 12 6 24 12 6 () [mm/s] 22 12 6 26 13 7 34 17 9 34
Actuator Specifications Supplement 1.1 Initial setting of LEY/LEYG series Model LEY16/LEYG16 LEY25/LEYG25 LEY32/LEYG32 LEY40/LEYG40 Lead symbol A B C A B C A B C A B C Lead [mm] 10 5 2.5 12 6 3 16 8 4 16 8 4 Stroke (mm) 300 300 300 400 400 400 500 500 500 500 500 500 Max. speed [mm/s] 500 250 125 500 250 125 500 250 125 300 150 75 Min. speed [mm/s] (Independent and interpolation) 15 8 4 18
-107No.JXC-OMT0001CN-C 1. 1.1 LEY/LEYG LEY16/LEYG16 LEY25/LEYG25 LEY32/LEYG32 LEY40/LEYG40 A B C A B C A B C A B C [mm] 10 5 2.5 12 6 3 16 8 4 16 8 4 [mm] 300 300 300 400 400 400 500 500 500 500 500 500 mm/s 500 250 125 500 250 125 500 250 125 300 150 75 [mm/s] () 15 8 4 18 9 5 24 12 6 24 12 6 [mm/s] () 22 12 6 26 13 7 34 17 9 34 17 9 1.2 LEFS LEFS16 LEFS25 A B H A B [mm] 10 5 20
SERVO MOTOR 121 to 126 12.1 Servo motor with a lock . 122 19 12.1.1 Features 122 12.1.2 Characteristics of servo motor with a lock 124 12.2 Protection from oil and water . 125 12.3 Cable . 125 12.4 Rated speed of servo motor. 125 12.5 Mounting connectors . 126 13.
No. 1 No. 2 No. 3 No. 4 No. 5 No. 6 No. 7 No. 8 64 32 16 8 4 2 1 1 0 0 0 0 0 0 1 2 0 0 0 0 0 1 0 ADDRESS 3 0 0 0 0 0 1 1 4 0 0 0 0 1 0 0 : : : : : : : : 125 1 1 1 1 1 0 1 CLEAR 0 OUTPUT STATE HOLD 1
Actuator Specifications Supplement 1.1 Initial setting of LEY/LEYG series Model LEY16/LEYG16 LEY25/LEYG25 LEY32/LEYG32 LEY40/LEYG40 Lead symbol A B C A B C A B C A B C Lead [mm] 10 5 2.5 12 6 3 16 8 4 16 8 4 Stroke (mm) 300 300 300 400 400 400 500 500 500 500 500 500 Max. speed [mm/s] 500 250 125 500 250 125 500 250 125 300 150 75 Min. speed [mm/s] (Independent and interpolation) 15 8 4 18
Actuator Specifications Supplement 1.1 Initial setting of LEY/LEYG series Model LEY16/LEYG16 LEY25/LEYG25 LEY32/LEYG32 LEY40/LEYG40 Lead symbol A B C A B C A B C A B C Lead [mm] 10 5 2.5 12 6 3 16 8 4 16 8 4 Stroke [mm] 300 300 300 400 400 400 500 500 500 500 500 500 Max. speed [mm/s] 500 250 125 500 250 125 500 250 125 300 150 75 Min. speed [mm/s] (Independent and 15 8 4 18 9 5 24 12 6 24
All setting are turned OFF at shipment, set to 125 kbps. Communication speed No.7 No.8 125 kbps OFF OFF 250 kbps ON OFF 500 kbps OFF ON ON ON HOLD/CLR setting (Switch No.9) The setting is as follows. The setting at shipment is turned OFF, set to CLR. HOLD/CLR No.9 Function CLR OFF Output is cleared when an error occurs.
(Rated voltage 125 V, Plug JIS C8303, Inlet IEC60320-C8) External output cannot be used when the AC adapter is being used. 20 - Doc. no. IZ*-OMT0002 7.
Note 1) Note 2) Maximum available stroke (mm) Bore size (mm) 20 25 32 40 Standard stroke (mm) Model Long stroke (mm) 1 pc. 201 to 350 301 to 400 301 to 450 301 to 800 25, 50, 75, 100, 125, 150, 200 D-C7, C8 D-B5, B6 D-H7 D-G5N 15mm 10mm 1500 25, 50, 75, 100, 125, 150, 200, 250, 300 20mm 20mm 15mm 10mm D-B59W D-H7LF Note 1) Intermediate strokes other than the above are produced upon receipt
Series AKH/AKB Check Valve with One-touch Fitting. 92 92 92 93 94 95 95 95 95 97 99 100 100 100 101 102 103 103 104 105 106 107 107 107 108 109 110 110 111 112 113 114 114 114 115 115 116 116 116 116 117 117 118 118 118 119 119 120 120 122 123 124 124 124 124 125 125 126 Features. Series AKH/AKB Check Valve with One-touch Fitting. How to Order. Specifications. Dimensions . Construction.
Data A Volume of cylinder/Capacity of converter 180 160 140 125 100 300 250 800 700 600 How to Select 200 10,000 8,000 6,000 5,000 4,000 3,000 500 400 qSelect the bore size of air-hydro cylinder 80 First of all, select a bore size from data
F (mm) Port B min. port size Weight (g) L2 L3 L4 L5 L6 P Q1 Q2 M L1 89 110 99 125 108 139 40 KM12-04-02-6 6 17 65 72 81 91 97 112 1 4 10 18 29.5 19.5 29 10.6 16 6 12 4 61.5 KM12-04-02-10 10 KM12-06-02-6 6 KM12-06-02-10 10 KM12-08-03-6 6 KM12-08-03-10 10 47 1 4 17 10 19.5 31.5 21.5 31 13 17 7.5 13.5 6 73 55 3 8 19 11.5 22.5 35.5 24 34.5 15.5 18.5 9 14.7 8 86 SKM, #7 to #12 KM13 Tube O.D.
to 160 125 to 250 Both directions Locking direction Bore size Locking direction One direction Bore size 40 to 160 Locking direction One direction Bore size 40 to 100 Locking direction One direction Bore size 40 to 63 Series MLGC Series CLK1 Series ML1C Locking direction One direction Bore size 32 to 63 Locking direction Both directions Bore size 20 to 40 Locking direction Both directions
135.5 93.5 106.5 137.5 148 104 117 137.5 148 114.5 127.5 150 160.5 125 138 162.5 173 135.5 148.5 175 185.5 146 159 187.5 198 30.5 43.5 75 85.5 62 75 100 110.5 72.5 85.5 112.5 123 51.5 64.5 87.5 98 L1 L2 L3 L4 4-14-36 37 Base Mounted 3 Port Solenoid Valve (Manifold: Connector Kit) Metal/Rubber Seal, Base Mounted, Plug Lead Unit Series VQZ100/200/300 Dimensions: VQZ200 VV3QZ25Stations Port
Series SZ3000 5 Port Solenoid Valve Serial Transmission Type. 52 53 54 55 56 57 57 59 60 60 61 62 63 64 65 66 67 67 69 70 70 71 72 73 74 75 76 77 77 79 80 80 81 82 83 84 85 87 89 91 97 97 98 100 101 101 102 103 104 105 106 106 107 111 111 114 121 125 130 130 132 134 137 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside
CQ2 75, 100, 125, 150, 175, 200 75, 100, 125, 150, 175, 200, 250, 300 20 Built-in Magnet Cylinder Model Double acting Action D 5, 10, 15, 20, 25, 30, 35, 40, 45, 50 RQ If a built-in magnet cylinder without an auto switch is required, there is no need to enter the symbol for the auto switch. (Example) CDQSL25-30D 25 For Manufacture of Intermediate Strokes, refer to page 552.
= 1 + 2 = (1.6 + 3.0) x 104 = 4.6 x 104 kgm2 Stroke time Note 2) Series MK MK2 Average piston speed Note 1) Stroke total Max. piston speed 120 mm/s 200 mm/s 75 mm/s 125 mm/s 0.35 sec. 0.2 sec. 25 mm Note 1) Average piston speed = Maximum piston speed 1.6. Note 2) Please use the stroke speeds indicated above.