of the main breaker of this product) Figure 3-6 Breaker operating characteristics curve HRZ Series 3.3 Procedure for Installation 3-9 3-9 HRX-OM-X010 Chapter 3 Transporting and Installation HRZ008-L-F HRZ008-L1-F 4h 2h 1h 30min 20min 14min 10min 6min 4min MAX MAX 2min 1min Operating time 30s 20s 10s MIN 5s 2s MIN 1s 0.5s 0.2s 0.1s 0.05s 0.02s 0.01s 100 135 200 300 400 500 600 700 1000 1500
(Page 9) 6 Bushing (bearing) 1000 fR[N] 100 Lateral load applied to rod end 100 80 63 10 50 40 1 0 500 1000 1500 Cylinder stroke [mm] Fig. 1 Allowable lateral load applied to rod end C a u t i o n Be certain to align the rod axis with the load and direction of movement when connecting.
Graph 1Allow lateral load 1000 Lateral load to rod end (N) 100 160 125&140 10 0 500 1000 1500 2000 Stroke(mm) Judging lateral load of dead weight In case of rotating type cylinder, lateral road applies to the piston rod because of dead weight of the cylinder. It needs to be checked, if the lateral load is within the range of safety.
Therefore, SMC products cannot be used for business or certification ordained by the metrology (measurement) laws of each country. 3 - 1Specification LEKFS*G Model LEKFS25 LEKFS32 LEKFS40 Stroke [mm] 50 to 800 50 to 1000 150 to 1200 Horizontal 15 28 40 40 50 68 26 60 75 Work load [kg] Note2) Vertical 3 7.5 15 4 10 18 4.5 4.5 25 Up to 400 20 to 1500 12 to 750 6 to 500 24 to 1300 16 to 1000
. *2 (4) S troke [mm] Standard Produced upon receipt of order 300 200 400 500 600 700 800 900 1000 1200 1500 Str o k e (m m ) Ty pe LEJS40 LEJS63 *2Strok es other than standard and produced up o n receipt o f order are available as special orders, so plea s e contact with our com pany . (9) Driver type *4 (7) Cable type *4 *5 *6 Com patible driv er P owe r supply v oltage [V ] Without cable
setting of LEP series Model LEP8 LEP16 Lead symbol J K J K Lead [mm] 8 4 10 5 Stroke (mm) Others 25 Others 25 Max. speed [mm/s] 300 250 150 350 250 200 Min. speed [mm/s] (Independent and interpolation) 20 10 20 10 Min. speed [mm/s] (Speed tuning control) 25 13 27 14 Supplement 1.5 Initial setting of LEFB series Model LEFB16 LEFB25 LEFB32 Lead symbol T Lead [mm] 48 Max. speed [mm/s] 1100 1400 1500
(Page 11) 7 1000 fR[N] 100 Lateral load applied to rod 100 80 63 10 50 40 1 0 500 1000 1500 Cylinder stroke [mm] Fig 1. Allowable lateral load applied to rod end C a u t i o n Be certain to align the rod axis with the load and direction of movement when connecting.
If the breaker with shorter operating time is connected, the customers equipment could be cut off due to the inrush current of the motor of this product. 4h 2h 1h 30min 20min 14min 10min 6min 4min MAX 2min 1min 30s 20s Operating time 10s 5s MIN 2s 1s 0.5s 0.2s 0.1s 0.05s 0.02s 0.01s 100 130 200 300 400 500 600700 1000 1500 2000 3000 4000 Current (% to the capacity of the main breaker of this
Signal Cable O.D. 6 mm 1 Brown: 24 VDC (For solenoid valve) Nominal cross section AWG22 2 White : 0 V (For solenoid valve) Wire diameter (Including insulator) 1.5 mm 3 Blue : 24 VDC (For control) Min. bending radius (Fixed) 40 mm 4 Black : 0 V (For control) 5 Gray : Not connected -30No.EX-OMN0011-F (2) Cable with power supply connector (SPEEDCON) Part number: PCA-140180 4 Cable length (L) 4 1500
Signal Cable O.D. 6 mm 1 Brown: 24 VDC (For solenoid valve) Nominal cross section AWG22 2 White : 0 V (For solenoid valve) Wire diameter (Including insulator) 1.5 mm 3 Blue : 24 VDC (For control) Min. bending radius (Fixed) 40 mm 4 Black : 0 V (For control) 5 Gray : Not connected -36No.EX-OMO0030-E (2) Cable with power supply connector (SPEEDCON) Part number: PCA-140180 4 Cable length (L) 4 1500
Cable colour: Signal Cable O.D. 6.6 mm 1 Brown: 24 VDC (For solenoid valve) Nominal cross section AWG22 2 White : 0 V (For solenoid valve) 3 Blue : 24 VDC (For control) Wire diameter (Including insulator) 1.65 mm 4 Black : 0 V (For control) 5 Gray : Not connected Min. bending radius (Fixed) 40 mm (2) Cable with power supply connector (SPEEDCON) Part number: PCA-140180 7 Cable length (L) 7 1500
. -42No.EX-OMH0025-C Specification Specifications Common specifications Item Specifications Ambient temperature -10 to 50 oC 2 Ambient humidity 35 to 85%RH (No condensate) Storage temperature -20 to 60 oC Withstand voltage 1500 VAC applied 1 minute (Between external terminals and the case) Insulation resistance 500 VDC 10 M or more (Between external terminals and the case) Operating environment
Solenoid valve supply voltage 24 VDC +10%/-5% Output channels 16 outputs Output type Sink/NPN (positive common) Connected load Solenoid valve with surge voltage suppressor of 24 VDC and 2.1 W or less (manufactured by SMC) Output when communication error occurs Clear Internal current consumption (Unit) 0.1 A or less EX120/121/122: IP20 EX124U/D: IP65 EX126D: IP67 Enclosure Withstand voltage 1500
Transmission speed [kbps] 9.6 19.2 45.45 93.75 187.5 500 1500 3000 6000 12000 Cable length [m] 1200 1000 400 200 100 : Cable Type A specification Item Specification Impedance 135 to 165 Capacity 30 pF/m or less Loop resistance 110 /km Wire diameter 0.64 mm or more Core cross-section 0.34 mm2 or more Lower-level bus Item Specification Number of branches for input/output 4 branches (16 points
Communication speed [kbps] 9.6 19.2 45.45 93.75 187.5 500 1500 3000 6000 12000 Cable length [m] 1200 1000 400 200 100 -19No.EX-OMN0028-B Setting and Adjustment Switch setting (1)Loosen the display cover screw (indicated by arrow). (2)Open the display cover using a flat head screwdriver, etc. (3)Set the switch using a small watchmaker's screwdriver with a thin blade, referring to the setting
10%/-5% Output channels 16 outputs 8 outputs Output type Sink/NPN (positive common) Connected load Solenoid valve with surge voltage suppressor of 24 VDC and 2.1W or less (manufactured by SMC) Output when communication error occurs HOLD/CLEAR (set using DIP switch) Internal current consumption (unit) 0.1 A or less Enclosure EX120/121/122: IP20 EX124U/D: IP65 Environment Withstand voltage 1500
GND terminal" Conduction between each input terminal and 12VDC or 24VDC terminal. power supply for sensor 12VDC 10%, 60 mA Preset output form Compare, hold, one-shot (fixed at 100 ms) Output method Individual 5 points output, binary code output Output time lag 5 ms or less (in normal output)/ 60ms or less (in binary output) Communication RS-232C Proof voltage Between case and AC line: 1500
Network length Communication speed [kbps] 9.6 19.2 45.45 93.75 187.5 Max. cable length [m] 1200 1000 Communication speed [kbps] 500 1500 3000 6000 12000 Max. cable length [m] 400 200 100 : Maximum cable length differs depending on the specifications of a cable. The above cable length is based on type A cable.
Also maximum response time of sensor for Hyrodless Monosashi-kun is maximum 1500 mm/sec (15Kcps) in cylinder speed. Reversed cylinder travelling direction 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 Cylinder stroke A phase output pulse B phase output pulse Counter value 0 1 2 1 3 4 3 2 Input / Output Input / Output of Hyrodless Monosashi-kun is performed by connector came from sensor.
(Page 9) 6 Bushing (bearing) 1000 Lateral load applied to rod end {N} (fR)[N] 100 100 80 63 50 10 40 32 1 1900 0 500 1000 1500 Cylinder stroke [mm] Fig. 1 Allowable lateral load applied to rod end C a u t i o n Be certain to align the rod axis with the load and direction of movement when connecting.