R O D B O R E S I Z E 7/16-20 7/16-20 7/16-20 3/4-16 3/4-16 3/4-16 1-14 1-14 1 1/4-12 1 1/2-12 1 7/8-12 5/8 5/8 5/8 1 1 1 1-3/8 1-3/8 1-3/4 2 2-1/2 S TA N D A R D S T R O K E 150 1.5 200 2 250 2.5 325 3.25 400 4 500 5 600 6 800 8 1000 10 1200 12 1400 14 E 1 G 1 3/8 H 1 3/4 J 2 K 2 1/2 L 3 M 3 1/2 Z Please consult P/A Customer Service for larger sizes.

MB 63 10% 30% 50% 600 Stroke mm 70% 30% AS3201F -02-12 400 200 70% 50% 10% 0 800 MB 80 600 Stroke mm AS5000-02 AS420-02 400 200 0 AN300 -KM12 T1209 800 MB 100 600 Stroke mm AS5000-02 AS420-02 400 200 0 800 CS1 125 600 Stroke mm AS5000-02 AS420-02 400 200 0 Solenoid valve Silencer Tubing Speed controller 200 300 400 500 600 700 800 900 1000 1100 1200 Speed at the end mm/s Applicable related

rate: 50% Stroke 500 mm Series CM2 Pressure 0.5 MPa Load rate: 50% Stroke 300 mm Average speed (mm/s) Series 800 700 600 500 400 300 200 100 0 Perpendicular, upward actuation SY3140-01 Horizontal actuation 800 700 600 500 400 300 200 100 0 SY5140-02 800 700 600 500 400 300 200 100 0 SY7140-03 800 700 600 500 400 300 200 100 0 SY9140-04 Cylinder is in extending.

6 CJ2 series Pressure: 0.5 MPa Load ratio: 50% Stroke: 60 mm 10 16 20 25 CM2 series Pressure: 0.5 MPa Load ratio: 50% Stroke: 300 mm 32 40 50 CA2 series Pressure: 0.5 MPa Load ratio: 50% Stroke: 500 mm 63 80 0 100 200 300 400 500 600 700 800 Average speed [mm/s] * Values at extension of a directly coupled cylinder when meter-out speed controllers are used with the needle full open. * The

Required installation space 800 mm or more Required installation space for ventilation and maintenance 400 mm or more 800 mm or more 800 mm or more 800 mm or more Piping 2000 mm or more Caution 1. Regarding the circulating fluid and facility water pipings, consider carefully the suitability for temperature, circulating fluid and facility water.

For installation indoors, ventilation ports and a ventilation fan should be equipped as needed. 800 mm or more Required installation space for ventilation and maintenance 400 mm or more 800 mm or more 800 mm or more 800 mm or more 4.

When the source pressure is 1700 psig (11.7 MPa), achievable delivery pressure is around 125 psig (0.86 MPa ) (HF and FC option 120 psig (0.83 MPa)). 2) 250 psig outlet pressure preset at 800 psig (5.5MPa) inlet pressure. Custom inlet/outlet pressure settings available. Please contact SMC. 3) 14 to 194F (10 to 90C) for Vespel seat.

to 400 301 to 450 301 to 800 GB GB TB GB ZZ ZZ 210 227.5 230.5 255 ZZ ZZ 206 223 226 250 ZZ ZZ 206 223 226 250 20 25 32 40 186 201 204 230 149 159 162 178 12 12 12 13 20 25 32 40 190 205.5 208.5 235 149 159 162 178 12 12 12 13 125 135 136 151 186 201 204 230 149 159 162 178 12 12 12 13 14 14 14 15 201 to 350 301 to 400 301 to 450 301 to 800 11 11 11 12 20 25 32 40 9-2-32 31 Series CLG1 Fine

Manual override Since the operations above 1. to 3. are the same as Series CVS1, refer to page 10-15-69. 40 e: 1000 siz re Piston speed (mm/s) Bo 800 0 5 600 63 400 200 0 1 2 3 Opening of throttle valve (Needle rotations) Conditions: Operating pressure 0.5 MPa, Horizontal mounting, No load, Spring return side The actuating speeds above are for reference.

1600 0 200 400 600 800 1000 1200 1400 1600 Stroke [mm] Stroke [mm] [Graph 7] Allowable load mass by stroke 40 100 y, z + A = 0 y, z + A = 50 Load mass [kg] y, z + A = 100 y, z + A = 200 10 y, z + A = 300 1 0 200 400 600 800 1000 1200 1400 1600 If load center of gravity exceeds the value of y, z + A on the graph, please consult SMC.

MYMW 16 Stroke 16 Standard strokes MYMW 20 Stroke 20 Bore size (mm) Standard stroke (mm) Max. manufacturable stroke (mm) MYMW 25 Stroke 25 MYMW 32 Stroke 32 16, 20, 25, 32, 40 100, 200, 300, 400, 500, 600, 700, 800 900, 1000, 1200, 1400, 1600, 1800, 2000 3000 40 MYMW 40 Stroke Note 1) A set of the parts below are included in each part number.

Drain cock: Gray Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com One-touch fitting N.C. auto-drain not available for AMD650.

.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Model/Self-standing Type AMF1000 Model 8000 AMF800 24000 AMF900 40 Port size (Nominal size B) 2B flange 2B, 3B, 4B flange 4B, 6B flange Weight (kg) 90 200 410 Rated flow (l/min (ANR)) Removes odor and gas ingredients in compressed air.

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Piping Caution 1. Connect it with IN and OUT ports in proper location. It does not work with the connection reversed.

flow rate: 5L/min, Ambient temp.: 25oC 1) Cooling capacity 1200 1000 Facility water 25oC Cooling capacity W Facility water 10oC 800 Facility water 35oC 600 400 200 0 0 10 20 30 40 50 60 70 Recirculating fluid temp. oC Fig.9-9 Cooling capacity (HED005) 2) Heating capacity 1400 1200 Heating capacity W 1000 Facility water 35oC 800 Facility water 10oC 600 Facility water 25oC 400 200 0 0 10 20

H 4 S y m b o l Initial power / Power 100 VAC 200/40 200/50 400/100 200 VAC 800/40 800/50 800/100 consumption (W) Heater assembly number XLA25-60S-1 XLA25-60S-2 XLA25-60S-2 XLA25-60S-3 No. of heater assemblies 1 pc. 1 pc. 1 pc. 1 pc.

H 4 S y m b o l Initial power / Power consumption (W) 100 VAC 200/40 200/50 400/100 200 VAC 800/40 800/50 800/100 Heater assembly number XLA25-60S-1 XLA25-60S-2 XLA25-60S-2 XLA25-60S-3 No. of heater assemblies 1 pc. 1 pc. 1 pc. 1 pc.

XL-25 XL-40 XL-50 XL-63 AC90240V Ass'y XLA25-60S-1 XLA25-60S-1 XLA25-60S-2 Ass'y 1 1 1 H4 AC100V 200/40 200/50 400/100 / AC200V 800/40 800/50 800/100 Ass'y XLA25-60S-1 XLA25-60S-2 XLA25-60S-2 XLA25-60S-3 Ass'y 1 1 1 1 H5 AC100V 200/40 400/70 400/80 600/130 / AC200V 800/40 1600/80 1600/80 2400/130 XL-80 XL-100 XL-160 AC90240V Ass'y XLA25-60S-3 XLA25-60S-2 XLA25-60S-2 Ass'y

/40 800/50 800/100 XLA25-60S-1 XLA25-60S-2 XLA25-60S-2 XLA25-60S-3 1 1 1 1 H5 AC100V 200/40 400/70 400/80 600/130 / AC200V 800/40 1600/80 1600/80 2400/130 XLD-80 XLD-100 XLD-160 AC90240V XLA25-60S-3 XLA25-60S-2 XLA25-60S-2 1 2 3 H4 AC100V 600/150 800/220 1200/350 / AC200V 2400/150 3200/220 4800/350 XLA25-60S-2 XLA25-60S-2 XLA25-60S-2 2 3 4 H5 AC100V 800/180 1200/300

If hunting is occurring, stop it controller. ) with a PID adjustment (parameter code: 800). See Improved Controllability.