Piston speed Caution The cylinder speed upper limit that retains the particle generation grade is 400 mm/s. Back matter 5 Clean series: Common Precautions 3 Be sure to read before handling. Refer to the main text for detailed precautions for every series.
For Air Upstream pressure of valve P1 z 1.0 MPa Downstream pressure of valve (P2) [MPa] 1.0 0.8 Subsonic Critical 0.9 0.6 pressure 0.8 0.7 Sonic 0.4 0.6 0.5 0.4 0.2 0.3 0.2 0.1 0 2 50 100 150 200 250 300 400 350 3 100 200 300 400 500 4 400 600 800 1,000 1,200 5 200 1,400 600 1,000 7 350 700 8 400 700 1,000 1,300 10 500 700 10 700 1,000 Flow rate Q [L/min (ANR)] How to read the graph The sonic
Specific Product Precautions 22 A ZL3/ZL6 Series Exhaust Characteristics (Representative value) ZL3H ZL3M 100 90 80 70 60 50 40 30 20 10 0 100 90 80 70 60 50 40 30 20 10 0 0.3 0.4 0.5 400 500 450 400 350 300 250 200 150 100 50 0 0.2 0.6 Vacuum pressure Suction flow rate [L/min(ANR)] Air consumption [L/min(ANR)] Suction flow rate [L/min(ANR)] Air consumption [L/min(ANR)] Vacuum pressure 350
speed (mm/s) Collision speed (mm/s) L unit 1000 1000 Air cushion 500 400 300 500 400 300 L unit Air cushion 200 200 1002 3 4 5 10 20 50 100 1 2 3 4 5 10 20 30 400 50 Caution Load weight (kg) Load weight (kg) 1.
400 2) Flow rate : 60L/min 5) Flow rate : 60L/min 75 50 25 0 25 50 75 75 50 25 0 25 50 75 -75 -50 -25 0 25 50 75 -75 -50 -25 0 25 50 75 0 0 mm mm ionizer to workpiece [mm] ionizer to workpiece [mm] Installation distance from Installation distance from 200 200 10m/s 400 400 10m/s 5m/s 600 600 5m/s 800 800 2m/s 2m/s 1000 1000 3) Flow rate : 250L/min 6) Flow rate : 180L/min 75 50 25 0 25 50
The highest value in the past 15 seconds is displayed relative to the rated torque of 100%. 0 to 400 % 9 Instantaneous torque Torque that occurred instantaneously is displayed. The value of the torque that occurred is displayed in real time relative to the rated torque of 100%. 0 to 400 % 10 Within one-revolution position Position within one revolution is displayed in encoder pulses.
MGP(kg) MGPM12100 (mm) (mm) 10 20 25 30 40 50 75 100 125 150 175 200 250 300 350 400 12 MGPM12 0.24 0.28 0.31 0.35 0.39 0.50 0.59 0.70 0.79 0.89 0.98 1.17 16 MGPM16 0.33 0.38 0.43 0.48 0.53 0.68 0.80 0.97 1.09 1.22 1.35 1.60 20 MGPM20 0.67 0.75 0.83 0.91 1.17 1.37 1.57 1.76 1.96 2.16 2.63 3.03 3.42 3.82 25 MGPM25 0.95 1.05 1.16 1.27 1.65 1.92 2.19 2.47 2.74 3.01 3.67 4.21 4.76 5.30 32 MGPM32
S4 40 400 S4 100 to 120VAC 100 to 120VAC LECSB1 LECSB1 B1 B1 25 100 S6 25 100 S6 Motor option 32 200 S7 AC servo motor (Absolute encoder 32 200 S7 AC servo motor (Absolute encoder LECSB2 LECSB2 200 to 230VAC B2 200 to 230VAC B2 B1,B2 B1,B2 Without lock Nil Without lock Nil 400 400 40 40 S8 S8 Cable length With lock B With lock B Without cable Without cable Nil Nil Ball screw lead Stroke
30 50 100 150 200 250 300 350 400 450 500 (kg) 0.580.62 0.73 0.87 0.98 1.09 1.20 1.181.25 1.42 1.68 1.86 2.03 2.21 2.382.56 2.09 2.20 2.49 2.77 3.17 3.46 3.74 4.03 4.32 4.60 4.89 LEY 16 D LEY 25 D LEY 32 D [mm] 1) 30 50 100 150 200 250 300 30 50 100 150 200 250 300 350 400 30 50 100 150 200 250 300 350 400 450 500 (kg) 0.580.62 0.73 0.87 0.98 1.09 1.20 1.17 1.24 1.41 1.67 1.85 2.02 2.20
C 10 20 30 800 600 400 200 0 0 10 20 30 40 50 60 70 Recirculating fluid temp. Fig. 5-6 Cooling capacity *The Radiating water flow rate of 1L/min is for reference. Radiating water Temp.20 Ambient Temp.20 Fluid water 1000 Cooling capacity W 5 Radiating water flow rate L/min 800 1 3 600 400 200 0 0 10 20 30 40 50 60 70 Recirculating fluid temp.
Bore (mm) Standard stroke (mm) Nylon tarpaulin 60C 110C Neo plain cloth 25, 50, 75, 100, 125, 150, 175, 200, 250, MG 40 Maximum ambient temperature for the rod boot itself. 300, 350, 400, 450, 500 25, 50, 75, 100, 125, 150, 175, 200, 250, MGP 50, 63 300, 350, 400, 450, 500, 600 25, 50, 75, 100, 125, 150, 175, 200, 250, MGQ 80, 100 300, 350, 400, 450, 500, 600, 700 MGG Minimum stroke of
rate: 50% Stroke 300 mm 6 10 16 20 25 32 40 Average speed (mm/s) Series 800 700 600 500 400 300 200 100 0 Perpendicular, upward actuation Horizontal actuation SYJ3140-M5 Cylinder is in extending.
Bore size Series MB Pressure 0.5 MPa Load factor 50% Stroke 500 mm Series CS1 Pressure 0.5 MPa Load factor 50% Cylinder stroke 1000 mm 50 63 80 100 125 140 160 180 200 250 300 Average speed (mm/s) Series 1000 1100 Perpendicular, upward actuation 900 Horizontal actuation 800 700 600 500 400 300 200 100 VK VQ7-8-FG-S-A03 VQ7-8-FG-S-RA03 VZ VF 0 1000 1100 VFR 900 800 700 600 500 400 300 200
Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 800 700 600 500 400 300 200 100 0 VQZ2121-C6 800 700 600 500 400 300 200 100 0 VQZ3121-C6 It is when the cylinder is extending that is meter-out controlled by speed controller which is directly connected with cylinder, and its needle valve with being
400, 450, 500 CA2 Up to 1800 50 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 -XC4 With heavy duty scraper -XC5 Heat resistant cylinder (10 to 110C) -XC6 Made of stainless steel*3 *4 Up to 2700 63 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 CS1 80 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 -XC7 Tie-rod
Dimension L (mm) Dimension L (mm) Dimension L (mm) Dimension L (mm) Station 2 3 4 5 6 7 Station 14 15 16 17 18 19 Station 20 21 22 23 24 Station 8 9 10 11 12 13 SE 165 175 190 205 215 230 245 260 280 290 300 310 400 405 420 435 450 320 335 350 365 375 385 SSQ1000 Note) Part number for a 10 piece set of elements. Refer to page 134 for replacement procedures.
Since 45% of the amount of clear water discharge is equivalent to 180 mL/min in the required specifications, 180 mL/min 0.45 = approximately 400 mL/min, indicating that a discharge rate of 400 mL/min is required for clear water. 3. Finally, find the pilot air pressure and pilot air consumption based on the flow-rate characteristic graphs.
Since 45% of the amount of clear water discharge is equivalent to 180 mL/min in the required specifications, 180 mL/min 0.45 = approximately 400 mL/min, indicating that a discharge rate of 400 mL/min is required for clear water. 3. Finally, find the pilot air pressure and pilot air consumption based on the flow rate characteristic graphs.
Standard stroke (mm) 60C Nylon tarpaulin 110C Neo plain cloth MXQ 25, 50, 75, 100, 125, 150, 175, 200, 250, 40 Maximum ambient temperature for the rod boot itse 300, 350, 400, 450, 500 MXF 25, 50, 75, 100, 125, 150, 175, 200, 250, 50, 63 300, 350, 400, 450, 500, 600 MXW 25, 50, 75, 100, 125, 150, 175, 200, 250, 80, 100 300, 350, 400, 450, 500, 600, 700 MXP Minimum stroke of auto switch
Mounting angle 10.6 300 7.0 200 LAT3m-10, -20 3.5 100 LAT3m-30 0.0 0.0 0 (Horizontal) 15 30 45 60 75 90 (Vertical) Mounting angle [] Shortest Positioning Time (Guide): Tmin [ms] Fig. 3 Fig. 4 Allowable Thrust Setting Value LAT3-m LAT3F-m 100 300 400 75 Shortest positioning time Tmin [ms] Shortest positioning time Tmin [ms] 6 86 350 W = 300 W = 400 W = 500 LAT3m-10 120 250 W = 400 W = 500