Rated voltage CE-compliant For DC 5 6 V S R 24 VDC 12 VDC 6 VDC 5 VDC 3 VDC B: Locking slotted type CE-compliant For AC (50/60Hz) 1 2 3 4 100 VAC 200 VAC 110 VAC [115 VAC] 220 VAC [230 VAC] Electrical entry 24, 12, 6, 5, 3 VDC / 100, 110, 200, 220 VAC Grommet L plug connector M plug connector G: Lead wire length 300 mm L: With lead wire (Lead wire length 300 mm) M: With lead wire (Lead wire
VBAT10A1 S Note) A safety valve port is provided only when option R or S is selected.
Refer to Minimum Stroke for Auto Switch Mounting on page 22. 16 Smooth Cylinder Series CS2Y 125, 140, 160 Basic Double Rod Type Smooth Cylinder Auto Switch Made to Order How to Order 160 Y L 300 CS2 L 300 160 M9BW Y CDS2 With auto switch With auto switch (Built-in magnet) Number of auto switches Nil S 3 n 2 pcs. 1 pc. 3 pcs. n pcs.
(CO2) [mg/L] 4.0 or less v Reference item 5 s 2 s 1 s Min. 0.5 s 0.2 s 0.1 s *1 In the case of [Mcm], it will be 0.003 to 0.01.
Combination of R and S (Because S function is also included in R.) Combination of S and T (Because S function is also included in T.) Combination of K and V (Only one or the other may be attached.) Note 2) Standard specification is the power cable with plug.
FN112-10-S FN4102-20-S i u y o i y o t OUT IN OUT IN OUT u IN DRAIN DRAIN DRAIN Number is the same as the Replacement Seal List of the Best Pneumatics No.7 Series FN1/FN4.
FN112-10-S FN4102-20-S i u y o i y o t OUT IN OUT IN OUT u IN DRAIN DRAIN DRAIN Number is the same as the Replacement Seal List of the Best Pneumatics No.7 Series FN1/FN4.
Rated voltage For DC 5 6 V S R 24 VDC 12 VDC 6 VDC 5 VDC 3 VDC B: Locking slotted type Electrical entry 24 VDC, 12 VDC, 6 VDC, 5 VDC, 3 VDC Grommet L plug connector M plug connector G: 300 mm lead wire L: 300 mm lead wire M: 300 mm lead wire MN: Without lead wire Light/Surge voltage suppressor Nil S Z R U Without light/surge voltage suppressor With surge voltage suppressor With light/surge
to 300 50 32 25 37 3 40 40 22 71 20 110 20 16 10 M26 x 1.5 M12 x 1.75 depth 22 Up to 300 60 41 30 37 3 40 50 26 (mm) Bore size (mm) Stroke range (mm) 20 25 32 40 50 63 80 100 NA P S TA TB ZZ 11 11 77 1/8 24 114 Up to 200 11 11 77 1/8 29 119 Up to 300 11 11 79 1/8 35.5 121 Up to 300 12 12 87 1/8 44 139 Up to 300 13 13 102 1/4 55 162 Up to 300 13 13 102 1/4 69 162 Up to 300 122 3/8 80 196
Grommet: G Conduit: C 2-M 2-M L L K Approx. 300 K Q F D Approx. 280 D Q F C R C G (PF) 1/2 R E B A H E 2-P Port size A H 2-P Port size B DIN connector: D Conduit terminal: T 2-M 2-M L L K Cable 6.8 to 10 K 27.5 F F Q (Q) 34 S 25 U R C R C G (PF) 1/2 (44) E B A H D (S) E G (PF) 1/2 B A H D 2-P Port size 2-P Port size N.C.
Grommet: G Conduit: C Approx. 300 Approx. 280 D D Q F Q F C C G (PF) 1/2 R R E E A H 2-P Port size 2-M B B A H 2-P Port size 2-M L L K K DIN connector: D Conduit terminal: T Cable 6.8 to 10 27.5 F F Q (Q) S 34 25 U R C R C (44) G (PF) 1/2 E B A H D 2-P Port size (S) E G (PF) 1/2 B A H D 2-M 2-P Port size 2-M L L K K N.C.
S S OUT IN OUT IN IN IN Bottom With display rotating function One-touch fitting 8 Female thread Rc, NPT, G 1/4 OUT IN OUT IN S S IN 1 IN 1 Functions Bypass structure Sensor unit Protruding part (Refer to page 15 and 16 for details.)
, Hyteresis Repeatability With 50% of signal input 1 0.8 1 Output deviation factor (% F .S.)
Stainless Steel Cylinder Se ries CG5-S 20, 25, 32, 40, 50, 63, 80, 100 How to Order X165US TN CG5 L N 25 S R 100 Without Auto Switch X165US TN CDG5 L N 25 S 100 G5BAL R With Auto Switch Inch rod thread (Only available with "TN" port option. Currently only available on the 20 to 63mm bore sizes.)
load F [N] 500 500 50 400 400 RZQ RS1H50, 63, 80 300 300 1.0 RS1H80 MI W S RS1H50 200 200 RS1H63 0.9 Operating pressure P [MPa] 0.8 100 100 CEP1 0.7 10 20 30 40 10 20 30 40 0 0 0.6 CE1 Transfer speed [m/min] = 0 Transfer speed [m/min] = 0.1 0.5 0.4 CE2 Graph (3) Graph (4) Bore size 20, 32/ = 0 Bore size 20, 32/ = 0.1 0.3 ML2B 0.2 0.1 C J G5-S 80 80 1000 2000 3000 4000 0 5000 Lateral
400 RS H A 63 Lateral load F [N] 500 500 50 400 400 RZQ RS1H50, 63, 80 300 300 1.0 RS1H80 MI W S RS1H50 200 200 RS1H63 0.9 Operating pressure P [MPa] 0.8 100 100 CEP1 0.7 10 20 30 40 10 20 30 40 0 0 0.6 CE1 Transfer speed [m/min] = 0 Transfer speed [m/min] = 0.1 0.5 0.4 CE2 Graph (3) Graph (4) Bore size 20, 32/ = 0 Bore size 20, 32/ = 0.1 0.3 ML2B 0.2 0.1 C J G5-S 80 80 1000 2000 3000
588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 9 Varistor Varistor S Coil Coil 12 VDC or less There are manual overrides in 2 directions, on the top and on the side (solenoid side).
pressure P1 (MPa) IR IR2010-02 IR2010-02 IR2010-02 Supply pressure: 0.7 MPa Back pressure: 0.7 MPa 0.7 VEX 0.204 0.4 0.6 Set pressure P2 (MPa) Set pressure (MPa) Set pressure (MPa) AMR 0.202 0.5 Set point 0.3 ITV 0.4 0.200 0.2 0.3 IC 0.198 0.2 0.1 VBA 0.1 0.196 VE 0 100 200 300 400 500 0 0.2 0.1 0.3 0.4 0.6 0.5 0.8 0.7 0.9 0 100 200 300 400 500 600 700 800 900 1.0 Flow rate ( /min (ANR))
mm) M: With lead wire (Length 300 mm) MN: Without lead wire D: With connector G: Lead wire length 300 mm LN: Without lead wire LO: Without connector MO: Without connector DO: Without connector H: Lead wire length 600 mm Light/Surge voltage suppressor Nil None Z With light/surge voltage suppressor With surge voltage suppressor S Type LN, MN: With 2 sockets.