Applicable cylinder bore (mm) 10 16 20 25 32 Part no. Applicable cylinder bore (mm) 10 16 20 25 32 NTP-010 NTJ-015A NT-015A NT-02 NT-03 WCS4 x 0.7 WCS5 x 0.8 WCS6 x 1 WCS8 x 1 WCS10 x 1 9.2 11. 5 15. 0 19. 6 8 10 13 17 M5 x 0.8 M6 x 1.0 M8 x 1.25 M10 x 1.25 4 5 5 6 7.8 9.8 12. 5 16. 5 1261
) Manual override 2NPTF (P port) 2NPTF (P port) 10 60.9(GZ:61.6) [62.6] 59.9(GZ:60.6) [61.6] 10 78.8(GZ:80.2) [82.2] 91.7(GZ:93.1) [95.1] 35 B B B B B 19 P 40 39 P 35 A A A A A 19 2 MAX.5 10 10 (Lead wire length) G : About 300 H : About 600 24.5 (Pitch) P=10.5 10.5 (Mounting holes) L2 4 L1 (Non-locking) Manual override A A 20 48.5 [55] 15 B B 5 36.1 1.5 29.5 A A (Pitch) P=10.5 17.5 2n-One-touch
Ltd. 1-16-4 Shimbashi, Minato-ku, Tokyo 105-0004, JAPAN Tel: 03-3502-2740 Fax: 03-3508-2480 URL http://www.smcworld.com 2003 SMC CORPORATION All Rights Reserved 1st printing August, 2003 D-YGA P-120 (YG) All specifications in this catalog are subject to change without notice. Printed in Japan. This catalog is printed on recycled paper with concern for the global environment.
Ltd. 1-16-4 Shimbashi, Minato-ku, Tokyo 105-0004, JAPAN Tel: 03-3502-2740 Fax: 03-3508-2480 URL http://www.smcworld.com 2001 SMC CORPORATION All Rights Reserved 1st printing October, 2001 D-SMC.L.A. P-80 (D) All specifications in this catalog are subject to change without notice. Printed in Japan. This catalog is printed on recycled paper with concern for the global environment.
9 Appendix 9.5.4 Recirculating fluid Pressure Loss Fluid: Water HED003 35 30 Pressure loss kPa 25 HED003-HW13 20 15 10 HED003-HW19 5 0 0 2 4 6 8 10 12 14 16 18 20 Flow rate L/min Fig.9-13 Recirculating fluid Pressure loss (HED003) HED005, HED007 35 30 Pressure loss kPa 25 HED005-HW13 HED007-HW13 20 15 10 HED005-HW19 HED007-HW19 5 0 0 2 4 6 8 10 12 14 16 18 20 Flow rate L/min Fig.9-14 Recirculating
JM-045 JM-10 JM-10 JM-045 JM-045 *Components include in a seal kit.
Allowable voltage fluctuation is 10% of the rated voltage.
Please See Below for How to Order Piston Rod Assembly 7 Rod Bushing Bronze casting Available only as an Assembly Please See Rod/Head Cover NC1A400-10-124 NC1A200-10-124 NC1A250-10-124 NC1A325-10-124 8 Cushion Valve Carbon steel NC1A150-10-124 9 Tie Rod Carbon steel Please See Below for How to Order Tie Rod NCA325-13-Q6311 5008-131 NCA325-31-Q6311 NCA200-13-Q6309 5008-93 NCA250-13-Q6309 5008
(mm) 3.2 4 6 8 10 12 D Tubing I.D.
Nijverheidsstraat 20 B-2160 Wommelgem Belguim TEL: 03-355-1464 FAX: 03-355-1466 TAIWAN SMC Pneumatics (Taiwan) Co.,Ltd. 17, Lane 205, Nansan Rd., Sec.2, Luzhu-Hsiang, Taoyuan-Hsien, TAIWAN TEL: 03-322-3443 FAX: 03-322-3387 POLAND SMC Industrial Automation Polska Sp.z.o.o. ul.
AS2052F-A AS1002F-A AS2002F-A 500 Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa 01, 23, 03, 04, 06, 07 100 08, 09 06, 07 Flow rate [L/min (ANR)] Flow rate [L/min (ANR)] Flow rate [L/min (ANR)] 400 200 06, 07 03, 04 300 50 200 100 100 0 0 0 0 5 10 0 5 10 0 5 10 Number of needle rotations Number of needle rotations Number of needle rotations AS3002F-A AS4002F-A 1500
R S AMR 4 0 00 02 E 3 Auto drain Additional symbol Port size 1 None With auto drain 0 Flow direction: left to right MR unit Flow direction: right to left 02 03 04 06 10 1/4 3/8 1/2 3/4 1 Applicable model AMR300-02 to 03 AMR400-02 to 04 AMR500-04 to 06 AMR600-10 R 3 4 5 6 Body size 3 4 5 6 Adapter ass'y port size (2 pcs.) 8 3 standard standard standard Pressure switch 1 2 E2 E3 E4 E6 E10
V) 1, 2 0 V 0.1 V 10 V Current output 1 4 mA 4.16 mA 20 mA Models Minimum value of rated flow range Maximum value of rated flow range PF2MC7501 5 L/min 500 L/min PF2MC7102 10 L/min 1000 L/min PF2MC7202 20 L/min 2000 L/min 1: Analogue output accuracy is within 3%F.S. 2: Set the current to the analogue output from the connected equipment to 20 A or less when selecting 0 to 10 V.
Applicable model 02 03 04 06 10 1/4 3/8 1/2 3/4 1 8 3 Pressure gauge 3 4 5 6 1 AMR300-02/03 AMR400-02 to 04 AMR500-04 to 06 AMR600-10 3 4 5 6 1 2 Nil E2 E3 E4 E6 E10 None None With pressure switch S Nil 4 3 1/4 3/8 1/2 3/4 1 Port size Adapter assembly Thread type Symbol Port size Nil N F Rc NPT G Thread type 02 03 04 06 10 1/4 3/8 1/2 3/4 1 The port size of adapter assembly is same as the
Applicable model 02 03 04 06 10 1/4 3/8 1/2 3/4 1 8 3 Pressure gauge 3 4 5 6 1 AMR300-02/03 AMR400-02 to 04 AMR500-04 to 06 AMR600-10 3 4 5 6 1 2 Nil E2 E3 E4 E6 E10 None None With pressure switch S Nil 4 3 1/4 3/8 1/2 3/4 1 Port size Adapter assembly Thread type Symbol Port size Nil N F Rc NPT G Thread type 02 03 04 06 10 1/4 3/8 1/2 3/4 1 The port size of adapter assembly is same as the
Used as IO-Link device 18 to 30 VDC, including ripple (p-p) 10% Current consumption 25 mA or less Protection Polarity protection Switch output Select from NPN or PNP open collector output Max. load current 10 mA Max. applied voltage 30.0 V Residual voltage 1 V or less (at 10 mA) Short circuit protection Provided 2-screen (3-screen display available: sub display, 4 digits x 2) Main display
10 0 0 10 30 40 50 20 60 10 20 Discharge rate l/min Discharge rate l/min 1m = 3.28ft 1l/min = 0.035SCFM Selection from flow rate characteristic graphs (PA3000) Required specification example: 3.
10 0 0 10 30 40 50 20 60 10 20 Discharge rate l/min Discharge rate l/min Selection from flow rate characteristic graphs (PA3000) Required specification example: 3.
AMR 4 0 00 02 E 3 Auto-drain Pressure gauge mounting Port size 02 03 04 06 10 ARJ MR unit 1 None With auto drain 0 Flow direction: Right to left Nil Flow direction: Left to right Applicable model 1/4 3/8 1/2 3/4 1 Nil E2 E3 E4 E6 E10 R 3 4 5 6 AMR3 00-02 to 03 AMR4 00-02 to 04 AMR5 00-04 to 06 AMR6 00-10 AR425 to 935 Adapter assembly port size (2 pcs.)
L4 Note) Weight (g) 5 5.5 6.5 8.5 9.5 19 22 35 38 52 86 95 Model Applicable tubing O.D. d AS1002F-01 AS1002F-03 AS1002F-07 AS2002F-03 AS2002F-07 AS2052F-07 AS2052F-09 AS3002F-07 AS3002F-09 AS3002F-11 AS4002F-11 AS4002F-13 MIN.