PV SV 16. Select ccommunication speed (serial communication protocol) from the table below with [] key or [] key, and confirm by pressing SEL.
200 P = 0.5 MPa m MGTL63 P = 0.5 MPa 100 MGTM63 100 Load mass m (kg) Load mass m (kg) Larger than 100st Larger than 50st 50 40 50st or smaller 75, 100st 30 20 50 25, 50st 40 10 l 30 5 4 3 m 20 2 10 1 10 20 30 40 50 100 200 300 1 2 3 4 5 10 20 30 40 50 100 200 300 400 Eccentric distance l (mm) Eccentric distance l (mm) 300 300 200 MGTL80 P = 0.5 MPa 200 MGTM80 P = 0.5 MPa 100 Load mass m
33 44 55 66 (3) (RES)ON [8][2] [0][0] 1EA5 14 41 14 14.5.11 (1) (a) [4][0][0][1][F][F] 14.4.1 16 0 11 () 22 33 44 55 0 0 0 16 66 1 10 0 1 (b) [5][0][0][1][F][F] 14.4.1 0 16 0 0 0 16 1 10 0 1 14 42 14 (c) [5][4][0][1][F][F] 14.4.1 0 16 0 0 0 16 1 10 0 1 (d) [5][8][0][1][F][F] 14.4.1 0 16 0 0 0 16 1 10 0 1 14 43 14 (e) (DWELL) (DWELL) [6][0][0]
, 250, 300, 350, 400, 450, 500, 600, 700, 800 25 4000 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 32 5000 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 40 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 50 6000 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 63 Note1) Contact P/A in case of a stroke length beyond the maximum.
550 10 to 300 Parallel Stroke 701 to 800 20 to 550 12 to 330 6 to 180 24 to 750 16 to 500 8 to 250 30 to 750 20 to 550 10 to 300 range 801 to 900 24 to 610 16 to 410 8 to 200 30 to 750 20 to 550 10 to 300 901 to 1000 24 to 500 16 to 340 8 to 170 30 to 750 20 to 520 10 to 250 1001 to 1100 30 to 660 20 to 440 10 to 220 1101 to 1200 30 to 570 20 to 380 10 to 190 Max acceleration/deceleration
H 4 S y m b o l Initial power / Power consumption (W) 100 VAC 200/40 200/50 400/100 200 VAC 800/40 800/50 800/100 Heater assembly number XLA25-60S-1 XLA25-60S-2 XLA25-60S-2 XLA25-60S-3 No. of heater assemblies 1 pc. 1 pc. 1 pc. 1 pc.
Status (6): TEMP READY signal output continues since the temperature is now back within the Out Time range of 200 sec even though it was temporarily outside the Low range. Status (7): TEMP READY signal turns OFF when 200 sec has passed after the temperature rises above the High range.
RLQ MLU View A-A' ML1C DStandard Stroke BP BZ C D E F G GC A AA AB AC AD AE AF AP B Bore size (mm) 20 25 32 40 Stroke range (mm) -X 11 depth 8 26.5 73.5 6.8 75, 100, 125, 150, 200 M6 x 1 depth 12 13 94 16.5 70 135 Rc 1/8 Rc 1/8 Rc 1/8 Rc 1/8 50 118 28 35 32 12 14 depth 10 31.5 86.5 8.6 M8 x 1.25 depth 16 16 104 19 75 160 50 140 29 40 37 16 2075, 100, 125, 150, 200, 250, 300 14 depth 10 31.5
RLQ MLU View A-A' ML1C DStandard Stroke B AF AP E A AA AB AC AD AE BP BZ C D F G GC Bore size (mm) 20 25 32 40 Stroke range (mm) -X 11 depth 8 26.5 73.5 6.8 75, 100, 125, 150, 200 M6 x 1 depth 12 13 94 16.5 70 32 35 Rc 1/8 Rc 1/8 Rc 1/8 Rc 1/8 50 28 135 118 12 14 depth 10 31.5 86.5 8.6 M8 x 1.25 depth 16 16 19 104 75 37 40 50 29 160 140 16 2075, 100, 125, 150, 200, 250, 300 14 depth 10 31.5
4 Dimensions MXZ12 Page 7 MXZ16 Page 8 2 Compact Cylinder with Linear Guide MXZ Series 12, 16, 20, 25 RoHS How to Order MXZ 20 20 M9BW Bore size Number of auto switches 12 12 mm 16 16 mm 20 20 mm 25 25 mm Pilot port location Nil 2 S 1 n n Front Nil * The number of auto switches that can be mounted depends on the bore size and the port location of the product.s P. 16 Pilot port Right Auto
S3 32 200 S3 200 to 230VAC LECSA2 A2 200 to 230VAC LECSA2 A2 Both side D Both side D 40 400 S4 40 400 S4 100 to 120VAC 100 to 120VAC LECSB1 LECSB1 B1 B1 25 100 S6 25 100 S6 Motor option 32 200 S7 AC servo motor (Absolute encoder 32 200 S7 AC servo motor (Absolute encoder LECSB2 LECSB2 200 to 230VAC B2 200 to 230VAC B2 B1,B2 B1,B2 Without lock Nil Without lock Nil 400 400 40 40 S8 S8 Cable
1 2 3 4 5 6 7 8 9 10 11 12 13 80 0 5 10 15 20 25 30 35 40 45 50 55 60 Load capacity (N) Load capacity (pounds) 63 300 12.0 280 11.0 Distance from pivot point (inches) 260 Distance from pivot point (mm) 10.0 240 9.0 220 200 8.0 180 7.0 160 6.0 140 5.0 120 100 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 4.00 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 Load capacity (N) Load capacity
(mm) Stroke range Bore size (mm) I J K M B D C E KA GA GB H 40 50 63 78 92 110 M6 x 1.0 M8 x 1.25 M8 x 1.25 25 25 25 10 14 14 45 55 68 21 26 32 36 46 53 34.5 40 46.5 40 45 50 46 55 66 59 71 82 23.5 28 34.5 to 1000 to 1000 to 1000 Stroke range Bore size (mm) MM XA XL Y ZZ MA MB MC N P S 40 50 63 M6 x 1.0 M8 x 1.25 M8 x 1.25 12 16 16 6 6 6 9.5 12.5 15 178 195 221 16 16 16 12 15 15 44 50 56
Note 1) Metric size 23 3.2 Note 2) 04 4 06 6 08 8 10 10 12 12 16 16 Inch size Note 3) 01 1/8" 03 5/32" 07 1/4" 09 5/16" 11 3/8" 13 1/2" Indicator window direction Elbow Universal Nil 0 Indicator window Note 1) For selecting applicable tubing O.D., refer to the Model on page 16. Note 2) Use 1/8" tubing.
Table4-1 Quality standard for facility water (tap water) Item Standard value pH25oC 6.5 to 8.2 Electric conductivity (25oC) (s/cm) 100 to 800 Chloride ion (mgCl-/L) 200 or less Sulfate ion (mgSO42-/L) 200 or less Acid consumption (pH4.8) (mgCaCO3/L) 100 or less Total hardness (mgCaCO3/L) 200 or less Calcium hardness (mgCaCO3/L) 150 or less Quality item Ion silica (mgSiO2/L) 50 or less Iron
/13 VA VCL40: 19/16 VA VCL40: 13 VA Holding Note 1) When the ambient temperature or fluid temperature is 60C or more, use high temperature specifications (class H coil).
Do not use the product when the flow exceeds 4.23 gpm(16 L/min)., since the flow cannot be displayed accurately.
200 203 Series CDQ2 With Auto Switch.
CJ216 15, 30, 45, 60, 75, 100, 125, 150, 175, 200 16 Air cushion is not available for 21-/22-.
M5 x 0.8 12-CY3B10 10 500 50, 100, 150, 200, 250, 300 12-CY3B15 15 1000 50, 100, 150, 200, 250, 300, 350, 400, 450, 500 12-CY3B20 20 100, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 Rc1/8 NPT1/8 G1/8 12-CY3B25 25 (Both sides) Non-lube 12-CY3B32 32 1300 Rc1/4 NPT1/4 G1/4 12-CY3B40 40 100, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 12-CY3B50 50 12-CY3B63 63