SMC Corporation of America
Elite Part Number Search
Search Results "ISE77G-02-L2-MS"

N,lax. 120'F (50'C) 20 ms or less (7OPS|) 600 cpm , Slotted Knob locking type Individual, Common Not (Use turbine oil # 1 (lSO VG32) if lubrication is Drovided.)

Elbow/Universal Type Flow rate and effective area AS221FM-02 AS221FM-01 Model AS121FM-M5 AS231FM-02 AS231FM-01 AS131FM-M5 3.2, 4, 6 6, 8 Metric sizes 3.2, 4 8, 10 4 6 Tubing O.D. 1/8", 5/32", 3/16" 1/4" 3/16", 1/4" 5/16" 1/4", 5/16" 3/8" Inch sizes 1/8", 5/32" 5/32" 3/16" 38 (1.33) 7 (0.25) Flow rate l/min (ANR) (CFM) 12 (0.42) Controlled flow 0.6 (0.03) 0.2 (0.01) 0.1 (0.006) Effective area

IS ZSM PF2 Pressure Sensor Controller IF Series PSE300 18 9.6 Data Response Time ms 20.8 Set Pressure Resolution Can be mounted in close proximity with each other either horizontally or vertically.

rate range Rated flow range Minimum set unit Water 1.7 to 17.0 l/min 0.35 to 4.5 l/min 3.5 to 45 l/min 7 to 110 l/min 1.7 to 17.0 l/min 0.35 to 4.5 l/min 3.5 to 45 l/min 7 to 110 l/min 2 to 16 l/min 0.5 to 4 l/min 5 to 40 l/min 10 to 100 l/min 0.1 l/min 0.05 l/min 0.5 l/min 1 l/min 0.1 l/pulse 0.05 l/pulse 0.5 l/pulse 1 l/pulse Accumulated pulse flow rate exchange value (Pulse width: 50 ms

Tap Water (as a Circulating Fluid) Quality Standards The Japan Refrigeration and Air Conditioning Industry Association JRA GL-02-1994 Cooling water system Circulation type Make-up water Item Unit Standard value Influence Corrosion Scale generation Voltage pH (at 25C) 6.0 to 8.0 v v Electric conductivity (25C) [mS/cm] 100*1 to 300*1 v v Chloride ion (Cl) [mg/L] 50 or less v Sulfuric acid

ZQ 05 1U A-K15LO B-VA M W-3 3-N (1) (2) (3) (4) (5) (6) (7)(8) (9) (1) (6) 05 0.5 07 0.7 W (2m) 10 1.0 (7) (V ) (8) (P ) (2) 1U 0 (M5x0.8) 3M 1 3.2 () 0 (M5x0.8) 2 4 () 2 4 () (3) 3 6 () 3 6 () 4 3.2 () 5 4 () B 5 4 () 1) (9) (4) ( [kPa] VA -100 to 100 NPN1 + VB PNP1 + N 1) ZFC (5) 2) M SI (kPa) 2) (99 10 ) ZZQ108A-B S C-A (1) (2) (3) (4) 1 (1) 2) 01 1 S () 02

10%, Ripple (p-p) 10% or less (with power supply polarity protection)45 mA or lessNPN 1 output, NPN 2 outputs, PNP 1 output, PNP 2 outputs80 mA28 V (at NPN output)1 V or less (with load current of 80 mA)2.5 ms (with anti-chattering function: 20, 100, 500, 1000, 2000 ms)Yes?0.2% F.S. ?1 digitVariable (0 or above)Variable (0 or above)0.8 to 5 V ?2.5% F.S.?

Applicable bore size B (C) (D) d H NT-02 20 13 (15.0) 12.5 M8 x 1.25 5 NT-03 25, 32 17 (19.6) 16.5 M10 x 1.25 6 NT-04 40 22 (25.4) 21.0 M14 x 1.5 8 Part no.

Bore size (mm) Mounting bracket Bore size (mm) Auto switch model 20 25 32 40 20 25 32 40 Axial foot D-C7, C8 CNG-L020 CNG-L025 CNG-L032 CNG-L040 BMA2-020 BMA2-025 BMA2-032 BMA2-040 D-H7 Flange CNG-F020 CNG-F025 CNG-F032 CNG-F040 D-B5, B6 Trunnion pin CG-T020 CG-T025 CG-T032 CG-T040 BA-01 BA-02 BA-32 BA-04 Clevis D-G5NT CG-D020 CG-D025 CG-D032 CG-D040 Front trunnion bracket CNG-020-24 CNG

BA 32 BA 04 BA 05 BA 06 BA 08 BA 10 BA 01 BA 02 BM1 01 BM1 02 BM1 32 BM1 04 BM1 05 BM1 06 The following stainless steel mounting screw kits (including set screws) are available for use depending on the operating environment. (Order the mounting band separately, as it is not included.)

Note 1) How to Order Sub-plate Note 2) VQ4000 Note 3) Electrical entry Port size P S Plug-in conduit terminal Plug lead 02 03 Rc1/4 Rc3/8 Piping B Side piping Note 1) Bottom piping type is applicable to only Rc1/4. Refer to p.1.11-46 for thread standard.

Pressure Range: ISE79S (0 to 50 MPa), Piping: 02 (Rc 1/4), Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m), Bracket: A (Bracket A, Interchangeable with ISE75[H])

Pressure Range: ISE70G (0 to 1 MPa), Piping: 02 (Rc 1/4), Orifice: None, Unit Specification: M (SI Unit Only)

Pressure Range: ISE76G (0 to 5 MPa), Piping: 02 (Rc 1/4), Orifice: None, Unit Specification: M (SI Unit Only)

Pressure Range: ISE76G (0 to 5 MPa), Piping: 02 (Rc 1/4), Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m)

Pressure Range: ISE75G (0 to 2 MPa), Piping: 02 (Rc 1/4), Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m)

Pressure Range: ISE70G (0 to 1 MPa), Piping: 02 (Rc 1/4), Orifice: None, Unit Specification: M (SI Unit Only), Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m)

Pressure Range: ISE70G (0 to 1 MPa), Piping: 02 (Rc 1/4), Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m), Bracket: None, Operation Manual/Calibration Certificate: Y (None)

Pressure Range: ISE76G (0 to 5 MPa), Piping: 02 (Rc 1/4), Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: S (Lead Wire with M12 Connector; Straight, 5 m), Bracket: A (Bracket A, Interchangeable with ISE75[H])

Pressure Range: ISE76G (0 to 5 MPa), Piping: 02 (Rc 1/4), Orifice: None, Unit Specification: M (SI Unit Only), Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m)