Rated Flow Range: 02 (20 to 2000 l/min), Output Specifications: L2 [Out1: IO-Link, Switch Output (N/P); Out2: Switch Output (N/P)], Lead Wire: N (w/o Lead Wire and M12 Connector), Unit Specification: Units Selection Function, Calibration Certificate: A (Yes)
Rated Flow Range: 02 (20 to 2000 l/min), Output Specifications: L2 [Out1: IO-Link, Switch Output (N/P); Out2: Switch Output (N/P)], Lead Wire: Q (Lead Wire and M12-M12 Connector, 3m), Unit Specification: M (SI Unit Only)
Sensor Range: 5 [For Positive Pressure (0~2MPa)], Port Size: 02 [R1/4 (M5 Female Thread)], Output Specifications: L2 (IO-Link/Switch: 1 output + 2 outputs), Lead Wire: L [w/Lead Wire and M12 Connector, (3 m), Right Angle]
0 1VY150 0 1VY170 0 11 1 0 2 VY190 0 11 2 4 0 Model VY1D00-M5 10 M5 01 M5 Port M5 01 02 01 02 02 03 20 04 02 03 04 04 06 10 12 14 P Port size Rc 11 2 1 1 8 1 8 1 4 1 8 1 4 1 4 3 8 1 2 1 4 3 8 1 2 1 2 3 4 1 1 1 4 A M5 M5 M5 2 1 4 R 2 1 0.11 0.16 Weight (kg) (1) 0.19 0.25 0.35 0.55 0.75 1.5 2 4 Hysteresis (2) 1% F.S. 2.5% F .S. 3% F .S. 5% F .S.
Symbol L1 L2 Calculation formula: L1 = 26n + 24, L2 = 26n + 12 Calculation formula: L1 = 26n + 36, L2 = 26n + 10 5-5-7 4 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 5-5-8 5 3 Port Air Operated Valve Series VTA315 How to Order SA VTA315 VA SA Port size Indicate
L1 Model T1 T2 D L1 L2 L3 XTO-2571-02 Rc1/4 52 52 21 57 XTO-2571-03 Rc3/8 XTO-1239-02 Rc1/4 84 80 37 79 XTO-1239-03 Rc3/8 Rc1/4 XTO-1239-04 Rc1/2 XTO-1719-06 Rc3/4 98 98 40 90 XTO-1719-10 Rc1 !
162.5 139 17 Stations L1 L2 L3 L4 11 298 287.5 267 15.5 13 14 15 16 12 310.5 300 283 13.5 323 312.5 299 12 348 337.5 315 16.5 360.5 350 331 14.5 373 362.5 347 13 40
ZSE10 ISE10 Reducing setting labor Minimizing risk of mistakes in setting ISE70 Copy Copy ZSE80 ISE80 PS ISA3 ISA2 ISE35 Master sensor 1 unit Slave side 2 units 10 units PSE 3-step setting 3-step setting IS ISG 1 2 3 ZSM1 Push Push Push Push Completion of setting Adjust to the set-value by the or button. Added vacuum range.
1/4 Rc 3/8 15.2 20.9 27 29 35.3 40 6 7.5 15.4 21.1 64 89 17 19 Weight (g) Connection thread D L1 L2 Q KEC-02 KEC-03 665
VE 3 Bleed port Model (Made to Order) Pressure range Note) Indication unit Connection thread VY1 Note Model MPa G43-2-01 to 02-X2 G43-4-01 to 02-X2 G43-6-01-X2 G43-7-01 to 02-X2 G43-10-01 to 02-X2 G43-2-01 to 02-X3 G43-4-01 to 02-X3 G43-6-01-X3 G43-7-01 to 02-X3 G43-10-01 to 02-X3 G43-2-01 to 02-X4 G43-4-01 to 02-X4 G43-6-01-X4 G43-7-01 to 02-X4 G43-10-01 to 02-X4 0 to 0.2 0 to 0.4 0 to 0.6
(mm) 04 06 08 10 12 Type 4 6 8 10 12 Port size Elbow Universal 2 3 01 02 03 04 R 1/8 R 1/4 R 3/8 R 1/2 Control type Meter-out Meter-in 0 1 With residual pressure release valve With One-touch fitting 15-9-36 2 Speed Controller with Residual Pressure Release Valve with One-touch Fitting, Elbow Type/Universal Type Needle Valve/Flow Characteristics AS2201FE-02, AS2211FE-02 AS2301FE-02, AS2311FE
Electrical entry SC (T only) Type SU Type SC Type SC Type SU Type SC Type SU AXT622-5A AXT336-4AStations AXT336-5Stations Description AXT336-1A-1 01 02 01 02 01 02 02 03 02 03 02 03 02 03 Manifold block assembly AXT336-1A-2 AXT336-1A-3 AXT336-2A-1AXT336-2A-2AXT336-3A-1AXT336-3A-2q End plate (U side) assembly w End plate (D side) assembly e Terminal assembly Junction cover assembly Tie-rod
Pressure Range: ISE70 (0 to 1 MPa), Piping: 02 (Rc 1/4), Output Specification: AB (Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type])
Pressure Range: ISE70 (0 to 1 MPa), Piping: 02 (Rc 1/4), Output Specification: AB (Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: S (Lead Wire with M12 Connector; Straight, 5 m)
Pressure Range: ISE70 (0 to 1 MPa), Piping: 02 (Rc 1/4), Output Specification: AB (Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: None, Operation Manual/Calibration Certificate: Y (None)
Pressure Range: ISE70 (0 to 1 MPa), Piping: 02 (Rc 1/4), Output Specification: AB (Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: S (Lead Wire with M12 Connector; Straight, 5 m), Bracket: B (Bracket B)
Pressure Range: ISE70 (0 to 1 MPa), Piping: 02 (Rc 1/4), Output Specification: AB (Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: B (Bracket B)
Pressure Range: ISE71 (0 to 1.6 MPa), Piping: 02 (Rc 1/4), Output Specification: AB (Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: S (Lead Wire with M12 Connector; Straight, 5 m), Bracket: A (Bracket A, Interchangeable with ISE70)
LED/24 VDC Port size Nil 02 N02 With gasket Rc 1/4 NPT 1/4 Note) Micro load type: Not available L2 option. 864
2 131 111 3 177 157 4 223 203 5 269 249 6 315 295 7 361 341 8 407 387 9 453 433 10 499 479 Formula: L1 = 46n + 39, L2 = 46n + 19 4-7-22