Operating time 20 s 30 s Voltage 10 s 5 s Min. 2 s dV dt 1 s = Voltage increase ratio 0.5 s dV 0.2 s 0.1 s Time 0.05 s 0.02 s dt 0.01 s 100 125 200 300 500 400 600 700 1000 2000 3000 4000 1500 < For option B [With earth leakage breaker]> 3. This product is installed with a breaker with the following operating characteristics.
Positioning time -> 0003h -> 0.03 s Number of bytes -> 02h -> 2 Example 2) When reading the target position (setting: 5000 m) and the positioning time (setting 0.03 s) for Step Data No. 10 of the controller with controller ID: 1 Request to be sent ":010305303CRLF" (are the checksum.)
Lead wire length symbols: 0.5 m Nil (Example) A54 3 m L (Example) A54L 5 m Z (Example) A54Z Besides the above models, there are some other auto switches that are applicable.
If the leakage volume is 30 L/min (ANR), the vacuum pressure of the S type is 20 kPa q w e, and for the L type it is 33 kPa q' w' e'. If the leakage volume is 5 L/min (ANR), the vacuum pressure of the S type is 80 kPa r t y, and for the L type it is 47 kPa r' t' y'.
Time [s] LEC SS-T T1 T2 T3 T4 T1 = V/a1 [s] T3 = V/a2 [s] LEC Y T2: Constant speed time can be found from the following equation.
Tubing size (O.D. x I.D.) mm: 12 x 9 IDG30L IDG50L 0 m 40 1 m 39 3 m 38 5 m Note) In cases other than above model numbers, if the tube length is 5 m or less, an increase of the outlet air at the atmospheric pressure dew point will be 1C or less. 14-19-25 22 Series IDG Single Unit/Standard Dew Point 60C Specifications How to Order 03 B IDG 60 S Option Flow rate by size None (Standard) With
-X Bore size (mm) W WA WB WH ZZ 2020 30 22 16 23 118 25 30 22 16 25 123 Data 32 25 22 16 28.5 125 40 20 22 16 33 143 50 20 25 18 40.5 167 63 20 25 18 47.5 167 80 20 30 22 60.5 201 100 20 31 22 71 202 10-14-13 14 Series CG5-S Dimensions R V Axial foot style (L): CG5LNS S + Stroke H GA GB Width across flats B1 2-Rc P H1 D B LH I AL A K KA MM Width across flats NA LT X Y X Y M 8-J 4-LD C 0.1
-X Bore size (mm) W WA WB WH ZZ 2020 30 22 16 23 118 25 30 22 16 25 123 Data 32 25 22 16 28.5 125 40 20 22 16 33 143 50 20 25 18 40.5 167 63 20 25 18 47.5 167 80 20 30 22 60.5 201 100 20 31 22 71 202 10-14-13 14 Series CG5-S Dimensions R V Axial foot style (L): CG5LNS S + Stroke H GA GB Width across flats B1 2-Rc P H1 D B LH I AL A K KA MM Width across flats NA LT X Y X Y M 8-J 4-LD C 0.1
Lead wire length symbols: 0.5 m Nil (Example) A54 3 m L (Example) A54L 5 m Z (Example) A54Z Since there are other applicable auto switches than listed, refer to page 6-9-30 for details.
Refer to page 829-10. 8-29-17 18 Dual Rod Cylinder: With End Lock For Retraction Side Series CXS 6, 10, 15, 20, 25, 32 How to Order CXS M Y7BW 50 S R 10 Number of auto switches Nil S n 2 pcs. 1 pc. n pcs.
Component Parts No. q w e r t y No. u i o !0 !
When exchanging the pilot valve assembly only, V115-D is interchangeable with V115-Y. Do not replace V111 (G, H, L, M, W) to V115-D/Y (DIN terminal), and vice versa. Electrical entry Y With connector DIN terminal YO Without connector 4-4-54 55 Series SYJ300/500/700 Made to Order Specifications: Please contact SMC for detailed specifications, delivery and pricing.
Vertical upward load Load extended horizontally Load retracted horizontally m m m Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Maximum speed (mm/s) Maximum speed (mm/s) Maximum speed (mm/s) up to 300 up to 500 up to 700 up to 300 up to 500 up to 700 up to 300 up
(500 VDC) between external terminal and case 10 to 500 Hz at whichever is smaller: 1.5 mm amplitude or 98 m/s2 acceleration in X, Y, Z directions for 2 hrs. each 490 m/s2 in X, Y, Z directions 3 times each 1000 Vp-p, Pulse width 1 s, Rise time 1 ns Resistance Note 1) In the case of PF2W711, 3% of F .S. or less (15C to 35C, based on 25C).
suppressor 5/32 4 N 100 VAC 10 one-touch fitting M 9/32 7 P 110 VAC A B C D E F 13/64 5 Q 200 VAC 1/4 5/16 8 R 230 VAC 25/64 10 S Conduit 24 VDC Aluminum 13/64 5 With surge voltage suppressor 3/8 5/16 8 VX2 T 100 VAC 25/64 10 Single U 110 VAC 3 Size 3 G H Unit 1/2 25/64 10 V 200 VAC N.C. 13/64 5 W 230 VAC J 10 one-touch fitting 5/16 8 K L 25/64 10 Faston terminal Resin 13/64 5 M N Y 12 one-touch
Connector type A B D M8-3 pins M8-4 pins M12-4 pins CJP Lead wire length S 0.5 (m)(1.64 ft) CJ2 M 1.0 (m)(3.28 ft) Auto Switch Mounting Bracket Part No.
Connector type A B D M8-3 pins M8-4 pins M12-4 pins CJP Lead wire length S 0.5 (m)(1.64 ft) CJ2 M 1.0 (m)(3.28 ft) Auto Switch Mounting Bracket Part No.
Series: 25A-ISE20, Rated Pressure Range: B (-0.1 TO 1 Mpa), Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: M (SI Unit Only), Piping Specification: M5 (Female Thread), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof)
Series: 25A-ISE20, Rated Pressure Range: -0.1 TO 1 Mpa, Output Specification: PNP Open Collector 2 Outputs + Copy Function, Unit Specification: SI Unit Only, Piping Specification: Female Thread, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: -