As an example, for a travel of 100 (mm) Travel distance of the actuator per 1 pulse = 0.001 (mm) *1 100 (mm)/0.001 (mm) = 10 (pulse) If the stroke end signals (LSP, LSN) are not turned ON, an alarm may occur.
(Supply pressure 0.3 MPa) External air inlet Compressed air External air inlet Yes None Reduced by 50% Air consumption flow rate L/min (ANR) 10 10 Ionized air Discharge time sec 2.5 2.5 5 Compressed air Improved 6 times Ionized air flow velocity m/s 0.4 At 300 mm distance External air inlet External air Neutralizing static electricity from an electric substrate Neutralizing static electricity
ms or more, Low level 0.4 V or less 1 T U O U O T2 T E S Indicator light (Green/Red) Enclosure IP40 Operating temperature range 5 6 7 8 10.4 16 Operating: 0 to 50C, Stored: 10 to 60C (with no freezing or condensation) 8 x M3 11 (4.5) 19.4 29 Operating humidity range 21.4 Operating/Stored: 35 to 85% RH (with no condensation) Environmental resistance Withstand voltage 1000 VAC for 1 minute
Material Note PBT PBT Description Body A Body B Needle Seat ring Spring U seal Cassette Seal O-ring O-ring O-ring O-ring Gasket 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Body A Elbow body Body B Needle Seat ring Spring U seal Cassette Seal O-ring O-ring O-ring O-ring O-ring Electroless nickel plated Electroless nickel plated Electroless nickel plated Brass
, IDF6E-10 IDF8E-10, IDF11E-10 Type 100 V 10 A IDU3E-10, IDU4E-10 IDU6E-10 30 mA IDF4E-20, IDF6E-20 IDF8E-20, IDF11E-20 Type 200 V 5 A IDU3E-20, IDU4E-20 IDU6E-20 S Option symbol IDF1E-10 to 11E-10, IDU3E-10 to IDU6E-10 With power cord connection The option allows the connection of a power cord to a terminal block.
Do not use in an environment with temperature cycles.
Bore size (mm) Piano wire u Return spring CUJB4-S-PS 4 Sintered metallic BC i Bronze element CUJB6-S-PS 6 Set of nos. above !1 and an exclusive grease pack. o Magnet CUJB8-S-PS 8 Steel Nickel plated !0 Rod end nut CUJB10-S-PS 10 NBR !1 Piston seal NBR !2 Rod seal NBR !
5 10*2 5 10*2 *1 For 5 and 10 mm strokes, lead wires will interfere with mounting surface. *2 For 5 mm stroke, it is possible to mount an auto switch, but 2-color display may not be available. *3 When mounting an auto switch from the top with 5 or 10 mm strokes, use a D-F8 auto switch. (1) Bottom mounting (2) When mounting an auto switch (3) Tube top mounting (When mounting an auto
[mm] *1 D1 Weight [g] With a rib X (X) Y Nylon Urethane Applicable tubing M L1 Oval type Round type 4 1/8 KQ2L04-01GS1 10 8.2 7.7 10 10 14.8 16.2 17.2 13.3 4.6 3.3 3 4.8 1/4 KQ2L04-02GS1 14 8.2 7.7 10 10 14.8 21.7 21.1 13.3 4.6 3.3 3 14.3 Rib 4, 6 8 to 16 6 1/8 KQ2L06-01GS1 10 10.4 9.7 12 10 15.5 17.3 19.4 13.3 11.4 9 4.5 5.2 1/4 KQ2L06-02GS1 14 10.4 9.7 12 10 15.5 22.8 23.3 13.3 11.4
Retainer prevents an accidental loss of needle.
VQZ VZ VS VFN Component Parts Replacement Parts No. u i o Note Part no.
to 40 39.5 31.5 6 6 29 5.5 10 38 5 8 20 3.5 6.5 M6 x 1.0 7 18 10 5 M4 x 0.7 10 to 60 44 34 8 8 36 5.5 16 47 7 10 25.5 5.4 9 M6 x 1.0 7 19.5 10 6 M5 x 0.8 10 to 60 47.5 37.5 10 10 40 5.5 20 52 8 10 28 5.4 9 M6 x 1.0 7 23 10 49.5 7 M6 x 1.0 10 to 50, 75, 100 54 42 12 12 45 8.5 25 60 4.5 10 12 34 5.5 9 M6 x 1.0 7 26 10 57 10 M8 x 1.25 10 to 50, 75, 100 60.5 48.5 13 16 52 8.5 28 69 5 14
Standard Stroke Model Standard stroke (mm) 10, 20, 30, 40, 50 MXQ6 10, 20, 30, 40, 50, 75 MXQ8 10, 20, 30, 40, 50, 75, 100 MXQ12 10, 20, 30, 40, 50, 75, 100, 125 MXQ16 10, 20, 30, 40, 50, 75, 100, 125, 150 MXQ20 10, 20, 30, 40, 50, 75, 100, 125, 150 MXQ25 8-5-9 10 Series MXQ Theoretical Output IN OUT The dual rod ensures an output twice that of existing cylinders.
Install an earth leakage breaker Note) suitable to each model for the power supply. Maintain voltage fluctuation within 10% of the rated voltage. Note) Select an earth leakage breaker with a sensitivity current of 30 mA. As regards rated current, refer to Applicable earth leakage breaker capacity on page 3.
For a 10 orifice (VXS23/Port size 1/4), P 0.05 MPa The optimum size for a pressure differential of P 0.2 MPa and a flow of 50 L/min will be the VXS23 (10 orifice, port size 3/8). 500 400 VXS26 25 Cv = 12 300 VXS25 20 Cv = 9.2 200 VXS24 15 Cv = 5.3 Flow rate Q [L/min] 100 VXS23 Port size 3/8 10 Cv = 2.8 VXS23 Port size 1/4 10 Cv = 2.4 50 40 30 25 20 10 0.01 0.02 0.03 0.04 0.05 0.1 0.2 0.3
(mm) Model OO PP SS VV QQ RR TT UU Applicable gasket ML1C25 ML1C32 ML1C40 C11.2 10 14 37 24 8 27 20 8 C11.2 16.5 18 46 30 12 32 22 8 C14 17 23.5 53 40 12.5 34 26 10 Model A B C D E F G H I J K L M N P Q S T O R U W Z V Y ML1C25 ML1C32 ML1C40 274 260 137 140 88 108 87 85.5 60 74 97 100 42.5 26 34 206 28 24 5.6 9 5.5 8.5 9.5 M5 x 0.8 M6 x 1 11 322 306 161 160 108 131 101 99.5 64 92 118 120
(mm) Model OO PP SS VV QQ RR TT UU Applicable gasket ML1C25 ML1C32 ML1C40 C11.2 10 14 37 24 8 27 20 8 C11.2 16.5 18 46 30 12 32 22 8 C14 17 23.5 53 40 12.5 34 26 10 Model A B C D E F G H I J K L M N P Q S T O R U W Z V Y ML1C25 ML1C32 ML1C40 274 260 137 140 88 108 87 85.5 60 74 97 100 42.5 26 34 206 28 24 5.6 9 5.5 8.5 9.5 M5 x 0.8 M6 x 1 11 322 306 161 160 108 131 101 99.5 64 92 118 120
CO N SU M PTI O N CU RREN T AT CO N STAN T O U YPU T 120M a O R LESS I N PU T SI G N AL D I G I TAL 10bi t ( PARALLEL I N PU T) I N PU T I M PED AN CE 4. 7k O R LESS LI N EARI TY 1% F.
If an instantaneous flow of 10 L/min lasts for 5 minutes, the accumulated flow will be 10 x 5=50 L. Accumulated pulse output A type of output where a pulse is generated every time a predefined accumulated flow passes.It is possible to calculate the total accumulated flow by counting the pulses.