SMC Corporation of America
Elite Part Number Search
Search Results "E400-06-A"

12.5 10 3.5 AS2001F-03-3 AS2001F-06-3 44.8 6.3 21.8 49.1 43.6 13.5 5/32" 9.3 40.7 5.2 20.7 48 42.5 12.7 11.6 6 AS2001F-05-3 AS2051F-06-3 12.5 53.2 6.7 25.7 53.5 48.1 17 3/16" 11.4 50 6.2 21.6 48.9 43.4 16.5 12.8 6 14 10 3.5 17 15.5 13 3.5 AS2001F-07-3 AS2051F-08-3 59.8 8.1 27 54.8 49.4 18 1/4" 13.2 52.2 7.1 22.5 49.8 44.3 17 8 15.2 AS2051F-05-3 AS3001F-06-3 59 7.4 31.3 60.1 54.7 17 3/16"

Symbol 0 A square plug set is normally used for the drain unit.

ZF ZP ZCU How to Order Ejector Manifold AMJ ZZMA 06 06 R Misc. Number of stations Port and silencer location R L B 01 1 station Right side Left side Both sides 10 10 stations (max.) Note) Right and left side are viewed from the front side of VAC port.

ASD Body size Port size M5 M5 x 0.8 U10/32 10-32UNF 1 M5 x 0.8 10-32UNF AS AS-FE 2 F A 1 AS 1 M5 06 0 E KE Body size 1 AS-FG F A 1 AS 2 01 06 2 0 S Body size 2/3/4 AS-FP AS-FM Body size Made to Order Refer to page 562 for details.

Body size Port size M5 M5 x 0.8 U10/32 10-32UNF 1 M5 x 0.8 10-32UNF AS 2 0 F A 1 1 M5 06 G Body size 1 AS 2 0 S F A 1 2 01 06 G Body size 2/3/4 Body size Made to Order Refer to page 678 for details. 2 1/8, 1/4 3 3/8 4 1/2 Push-lock type Type 2 Elbow 3 Universal Seal method Nil Without sealant S With sealant Note) Face seal method is used for the G thread type.

AS2001F-03 AS2001F-06 13 28.7 33.7 6.3 44.8 11.6 6 13.5 11.8 18 28.6 33.6 6.2 50 11.4 16.5 3/16" AS2001F-05 AS2051F-06 26 30.2 35.2 6.7 53.2 12.8 6 17 14.8 21 29.5 34.5 7.1 52.2 13.2 17 1/4" AS2001F-07 AS2051F-08 31 31.5 36.5 8.1 59.8 15.2 8 18 24 29.6 34.6 6.2 52.2 11.4 16.5 3/16" AS2051F-05 AS3001F-06 18 33.3 38.3 7.4 59 12.8 6 17 14.8 26 30.5 35.5 7.1 54.4 13.2 17 1/4" AS2051F-07 AS3001F

06, 07 10 6 4 500 5 2 0 5 10 0 0 0 5 10 Needle rotation (Turns) Needle rotation (Turns) 4.1-14 Series ASD Dimensions/Metric Applicable tube O.D. d ASD230F ASD330F/430F ASD530F/630F Applicable tube O.D.d L2 L2 L3 L3 M M D2 D2 L1 L1 L4 L4 H H (Width across flats) (Width across flats) D3 D3 A1 L5 L5 A1 A2 D1 D1 A2 T T Metric L4 L5 A1 A2 M MAX.

(mm) Model Model Accessory TM-04 TM-06 TM-08 2 x 6 TM-04 TM-06 TM-08 TM-10 TM-12 4 6 8 10 12 2.6 x 8 4 TM-10 3 x 8 TM-12 Dimensions: Multi-tube Holder N x D (Pitch) N x holding part Cutting groove for separation N (No. of holding parts) Applicable tubing O.D.

AS Series Brass Elbow Universal Electroless nickel plated How to Order 1 2 0 U01 A F AS 2 06 Push-lock type Body size Applicable tubing O.D.

1 Related Products: Holder Series TMH Specifications A holder for securing a speed controller (In-line type) with One-touch fitting. Ambient temperature 20 to 60C Material Polypropylene White Color Accessory: Round head Phillips screw for mounting (Black zinc chromated).

1 Related Products: Holder Series TMH Specifications A holder for securing a speed controller (In-line type) with One-touch fitting. Ambient temperature 20 to 60C Material Polypropylene White Color Accessory: Round head Phillips screw for mounting (Black zinc chromated).

Note 2) (Nominal size) is not needed as the part number starting with the AL-H is a dedicated number. Note 3) The material of seals (AL-128H-V to AL-137H-V) is EPDM-70. 503 A

Metric sizes Type 04 06 08 10 12 4 6 8 10 12 2 Elbow Control type 0 1 Meter-out Meter-in Port size M5 01 02 03 04 M5 x 0.8 1/8 1/4 3/8 1/2 With One-touch fitting Clean specifications Metal parts material Q G Brass (electoless nickel plated) Stainless steel 304 Needle Valve/Flow Characteristics AS121FP-M5 AS221FP-01 AS221FP-02 08,10 06,08 06 04 04 AS321FP-03 AS421FP-04 12 10 10,12 08 06 15

2 B 2 B 2 B 2 1 P P 1 A 4 A 4 A 4 A 4 A 4 * These figures show the JJ5SY3-10F2-05DR-C8.

(RES) A.10 Undervoltage A.12 Memory error 1 (RAM) A.13 Clock error A.15 Memory error 2 (EEP-ROM) A.16 Encoder initial communication error1 A.17 Board error A.19 Memory error 3 (Flash-ROM) A.1A Motor combination error A.1C Software combination error A.1E Encoder initial communication error 2 A.1F Encoder initial communication error 3 A.20 Encoder normal communication error 1 A.21 Encoder normal

A B A B A B B A B A B A B B A B A B A 10 16 2 2 6 6 2.5 2.5 1.5 1.5 0.5 0.5 4.5 4.5 3 3 3.5 3.5 8.5 8.5 0.5 0.5 2.5 2.5 6.5 6.5 3 3 2 2 1 1 5 5 3.5 3.5 4 4 9 9 1 1 Note) Adjust the auto switch after confirming the operating conditions in the actual setting.

A Series MGC 20 to 50 SZ + Stroke B D port C port A, B port B port A C port A port D port A View A-A GD GD Front mounting flange SB + Stroke B SA + Stroke A ZZ + Stroke A + Stroke B Bracket mounting With R Without R Stroke A stroke Stroke A + Stroke B ( ) Bore size (mm) W1 W2 SB SA GD ZZ GC SZ availability 30 30 Up to 200 96 50 9 176 21 20 35 st or more 89 110 30 30 96 50 9 183 21 25 60 st

Stabilize the source pressure by providing a tank and a vacuum regulator. Provide a vacuum switch valve to individual lines. Thus, in case of an error, each valve can be turned OFF to minimize the influences on other pads.

D Swivels Male Pipe Female Pipe A Part Number A B Dia.