SMC Corporation of America
Elite Part Number Search
Search Results "DM12S-06N-C1"

System: Q (Vacuum Pump System for Manifold), Valves: K (Supply Valve; N.C., Release Valve; N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: N (w/o Pressure Sensor, Digital Pressure Switch for Vacuum), Connector: C1 (Common Wiring, Plug-in for Manifold), Vacuum, V Port: 06 (Metric Size, ø6 One-touch Fitting)

System: Q (Vacuum Pump System for Manifold), Valves: K (Supply Valve; N.C., Release Valve; N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: N (w/o Pressure Sensor, Digital Pressure Switch for Vacuum), Connector: C1 (Common Wiring, Plug-in for Manifold), Vacuum, V Port: 06 (Metric Size, ø6 One-touch Fitting), Bracket: w/o Option, Pump System PE Port Female Thread: C (with Pump System PE Port

System: Q (Vacuum Pump System for Manifold), Valves: K (Supply Valve; N.C., Release Valve; N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: N (w/o Pressure Sensor, Digital Pressure Switch for Vacuum), Connector: C1 (Common Wiring, Plug-in for Manifold), Vacuum, V Port: 06 (Metric Size, ø6 One-touch Fitting), Bracket: w/o Option, Pump System PE Port Female Thread: w/o Option, Individual Release

System: Q (Vacuum Pump System for Manifold), Valves: K (Supply Valve; N.C., Release Valve; N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: N (w/o Pressure Sensor, Digital Pressure Switch for Vacuum), Connector: C1 (Common Wiring, Plug-in for Manifold), Vacuum, V Port: 07 (Inch Size, ø1/4" One-touch Fitting), Bracket: w/o Option, Pump System PE Port Female Thread: w/o Option, Individual Release

System: Q (Vacuum Pump System for Manifold), Valves: K (Supply Valve; N.C., Release Valve; N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: N (w/o Pressure Sensor, Digital Pressure Switch for Vacuum), Connector: C1 (Common Wiring, Plug-in for Manifold), Vacuum, V Port: 08 (Metric Size, ø8 One-touch Fitting)

System: Q (Vacuum Pump System for Manifold), Valves: K (Supply Valve; N.C., Release Valve; N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: N (w/o Pressure Sensor, Digital Pressure Switch for Vacuum), Connector: C1 (Common Wiring, Plug-in for Manifold), Vacuum, V Port: 09 (Inch Size, ø5/16" One-touch Fitting)

System: Q (Vacuum Pump System for Manifold), Valves: K (Supply Valve; N.C., Release Valve; N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: N (w/o Pressure Sensor, Digital Pressure Switch for Vacuum), Connector: C1 (Common Wiring, Plug-in for Manifold), Vacuum, V Port: 09 (Inch Size, ø5/16" One-touch Fitting), Bracket: w/o Option, Pump System PE Port Female Thread: C (with Pump System PE

System: Q (Vacuum Pump System for Manifold), Valves: K (Supply Valve; N.C., Release Valve; N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: N (w/o Pressure Sensor, Digital Pressure Switch for Vacuum), Connector: C1 (Common Wiring, Plug-in for Manifold), Vacuum, V Port: 09 (Inch Size, ø5/16" One-touch Fitting), Bracket: w/o Option, Pump System PE Port Female Thread: w/o Option, Individual

System: Q (Vacuum Pump System for Manifold), Valves: R (Supply Valve; Self-holding, Release Valve; N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: H (Digital Pressure Switch for Vacuum, -100 to 100, PNP 2 Outputs), Connector: C1 (Common Wiring, Plug-in for Manifold), Vacuum, V Port: 06 (Metric Size, ø6 One-touch Fitting)

System: Q (Vacuum Pump System for Manifold), Valves: R (Supply Valve; Self-holding, Release Valve; N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: N (w/o Pressure Sensor, Digital Pressure Switch for Vacuum), Connector: C1 (Common Wiring, Plug-in for Manifold), Vacuum, V Port: 08 (Metric Size, ø8 One-touch Fitting), Bracket: w/o Option, Pump System PE Port Female Thread: w/o Option, Individual

System: Q (Vacuum Pump System for Manifold), Valves: K (Supply Valve; N.C., Release Valve; N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: C (Digital Pressure Switch for Vacuum, 0 to -101, PNP 2 Outputs), Connector: C1 (Common Wiring, Plug-in for Manifold), Vacuum, V Port: 07 (Inch Size, ø1/4" One-touch Fitting), Bracket: w/o Option, Pump System PE Port Female Thread: w/o Option, Individual

System: Q (Vacuum Pump System for Manifold), Valves: R (Supply Valve; Self-holding, Release Valve; N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: N (w/o Pressure Sensor, Digital Pressure Switch for Vacuum), Connector: C1 (Common Wiring, Plug-in for Manifold), Vacuum, V Port: 07 (Inch Size, ø1/4" One-touch Fitting)

System: Q (Vacuum Pump System for Manifold), Valves: K (Supply Valve; N.C., Release Valve; N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: H (Digital Pressure Switch for Vacuum, -100 to 100, PNP 2 Outputs), Connector: C1 (Common Wiring, Plug-in for Manifold), Vacuum, V Port: 08 (Metric Size, ø8 One-touch Fitting)

System: Q (Vacuum Pump System for Manifold), Valves: K (Supply Valve; N.C., Release Valve; N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: N (w/o Pressure Sensor, Digital Pressure Switch for Vacuum), Connector: C1 (Common Wiring, Plug-in for Manifold), Vacuum, V Port: 06 (Metric Size, ø6 One-touch Fitting), Bracket: w/o Option, Pump System PE Port Female Thread: C (with Pump System PE Port

System: Q (Vacuum Pump System for Manifold), Valves: K (Supply Valve; N.C., Release Valve; N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: N (w/o Pressure Sensor, Digital Pressure Switch for Vacuum), Connector: C1 (Common Wiring, Plug-in for Manifold), Vacuum, V Port: 07 (Inch Size, ø1/4" One-touch Fitting)

. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Switch / Pressure sensor: D (Switch, 0 to -101 kPa, SI Units Only, PNP 2 Outputs), Connector: C1 [Common Wiring (plug-in) - w/o Lead Wire with Connector - w/o Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 08 (ø8 One-touch Fitting, Metric)

. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Switch / Pressure sensor: D (Switch, 0 to -101 kPa, SI Units Only, PNP 2 Outputs), Connector: C1 [Common Wiring (plug-in) - w/o Lead Wire with Connector - w/o Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 08 (ø8 One-touch Fitting, Metric), Vacuum Break Flow Adjustment: K (Vacuum Break Flow Adjustment Needle Screwdriver Operation

. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Switch / Pressure sensor: J (Switch, -100 to 100 kPa, SI Units only, PNP 2 Outputs), Connector: C1 [Common Wiring (plug-in) - w/o Lead Wire with Connector - w/o Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 07 (ø1/4 One-touch Fitting, Inch)

. / None), Rated Voltage: 5 (24 VDC), Vacuum Switch / Pressure sensor: J (Switch, -100 to 100 kPa, SI Units only, PNP 2 Outputs), Connector: C1 [Common Wiring (plug-in) - w/o Lead Wire with Connector - w/o Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 07 (ø1/4 One-touch Fitting, Inch)

. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Switch / Pressure sensor: B (Switch, 0 to -101 kPa, SI Units Only, NPN 2 Outputs), Connector: C1 [Common Wiring (plug-in) - w/o Lead Wire with Connector - w/o Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 07 (ø1/4 One-touch Fitting, Inch), Vacuum Break Flow Adjustment: J (Vacuum Break Flow Adjustment Needle Round Lock Nut