Magnet: Built-In, Mounting: Basic Style, Style: Non-lube Rubber Bumper, Bore Size: 32mm, Thread: Rc (or M5 Depending on Style, Bore Size, and Thread Combinations), Piping: Screw-in Piping, Stroke: 125mm, Stroke Adjust Symbol: 0 to 50mm, Rod Boot: None, Auto Switch: C73--Reed, DC Volt >5 <24, AC Volt <100, LED, Lead Wire or Prewired Connector: 5m, Number: 2 pcs. (Or None in the Case of No
Magnet: Built-In, Mounting: Basic Style, Style: Non-lube Rubber Bumper, Bore Size: 32mm, Thread: Rc (or M5 Depending on Style, Bore Size, and Thread Combinations), Piping: Screw-in Piping, Stroke: 150mm, Stroke Adjust Symbol: 0 to 50mm, Rod Boot: None, Auto Switch: C73--Reed, DC Volt >5 <24, AC Volt <100, LED, Lead Wire or Prewired Connector: 5m, Number: 2 pcs. (Or None in the Case of No
Magnet: Built-In, Mounting: Basic Style, Style: Non-lube Rubber Bumper, Bore Size: 32mm, Thread: Rc (or M5 Depending on Style, Bore Size, and Thread Combinations), Piping: Screw-in Piping, Stroke: 50mm, Stroke Adjust Symbol: 0 to 50mm, Rod Boot: None, Auto Switch: C73--Reed, DC Volt >5 <24, AC Volt <100, LED, Lead Wire or Prewired Connector: 5m, Number: 2 pcs. (Or None in the Case of No
Magnet: Built-In, Mounting: Basic Style, Style: Non-lube Rubber Bumper, Bore Size: 32mm, Thread: Rc (or M5 Depending on Style, Bore Size, and Thread Combinations), Piping: Screw-in Piping, Stroke: 75mm, Stroke Adjust Symbol: 0 to 50mm, Rod Boot: None, Auto Switch: C73--Reed, DC Volt >5 <24, AC Volt <100, LED, Lead Wire or Prewired Connector: 5m, Number: 2 pcs. (Or None in the Case of No
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 15, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~1, Cushion: Rubber cushion, Auto Switches: C73, Lead Wire
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 275, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: Rubber cushion, Specification: Built-in magnet, Port thread type: Rc,
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: Air cushion, Specification: Built-in magnet, Port thread type: Rc, Auto
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 246, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: M5 × 0.8, Auto Switches: C73, Lead Wire
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 395, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: M5 × 0.8, Auto Switches: C73, Lead Wire
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Auto Switches: C73, Lead Wire Length(m): 5, The number
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Auto Switches: C73, Lead Wire Length(m): 5, The number of
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: [Included] Presence, Cushion: Air cushion, Operating Pressure(MPa): 0.15 to 1.0, Specification: Built-in magnet, Support bracket: -, Auto
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 425, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: [Included] Presence, Cushion: Rubber cushion, Operating Pressure(MPa): 0.15 to 1.0, Specification: Built-in magnet, Support bracket: -
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 120, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: [Included] Presence, Cushion: Air cushion, Operating Pressure(MPa): 0.15 to 1.0, Specification: Built-in magnet, Support bracket: -, Auto
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 175, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: [Included] Presence, Cushion: Rubber cushion, Operating Pressure(MPa): 0.15 to 1.0, Specification: Built-in magnet, Support bracket: -
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: [Included] Presence, Cushion: Air cushion, Operating Pressure(MPa): 0.15 to 1.0, Specification: Built-in magnet, Support bracket: -, Auto
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 900, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: [Included] Presence, Cushion: Rubber cushion, Operating Pressure(MPa): 0.15 to 1.0, Specification: Built-in magnet, Support bracket: -
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 350, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: [Included] Presence, Cushion: Air cushion, Operating Pressure(MPa): 0.15 to 1.0, Specification: Built-in magnet, Support bracket: -, Auto
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 110, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: [Included] Presence, Cushion: Rubber cushion, Operating Pressure(MPa): 0.15 to 1.0, Specification: Built-in magnet, Support bracket: -
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,