, 800, 900, 1000 MQ XC24 With magnet shielding plate 50 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 XC57 With floating joint 6000 RHC 63 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 X206 Additional moving element mounting taps X210 Note 1) Intermediate stroke is available by the 1 mm interval.
900 1.0 Flow rate (l /min (ANR)) Relief flow rate (l /min (ANR)) Supply pressure P1 (MPa) IR2020-02 IR2020-02 IR2020-02 Supply pressure: 1.0 MPa Back pressure: 1.0 MPa 1.0 0.8 0.204 0.9 Set pressure P2 (MPa) Set pressure (MPa) 0.7 Set pressure (MPa) 0.8 0.6 0.202 0.7 Set point 0.5 0.6 0.200 0.5 0.4 0.4 0.3 0.3 0.198 0.2 0.2 0.1 0.1 0.196 0 200 400 600 800 0 200 400 600 800 1000 1200 1400
800 Ambient 20C Ambient 25C Ambient 32C Ambient 40C 600 600 400 400 200 200 Ambient 5C Ambient 5C 0 5 10 15 20 25 30 35 40 45 0 5 10 15 20 25 30 35 40 45 [50 Hz] Circulating fluid temperature [C] [60 Hz] Circulating fluid temperature [C] 012 018 024 A W HRS -20 (Single-phase 200 to 230 VAC) 1000 1000 Ambient 40C Ambient 32C Ambient 25C Ambient 40C 800 800 600 600 Ambient 32C 400 400 Ambient
Set "0" to send back data in less than 800 s or "1" to send back data in 800 s or more. Parameter No.PC21 RS-422 communication response delay time 0: Invalid 1: Valid, reply sent in 800 s or more (3) Station number setting Set the station number of the driver in parameter No.PC20. The setting range is station 0 to 31. 14 5 14.
current command) _ _ 0 5 Speed command (8 V/max. speed) _ _ 0 6 Servo motor-side droop pulses (10 V/100 pulses) (Note 2) _ _ 0 7 Servo motor-side droop pulses (10 V/1000 pulses) (Note 2) _ _ 0 8 Servo motor-side droop pulses (10 V/10 pulses) (Note 2) _ _ 0 9 Servo motor-side droop pulses (10 V/10 pulses) (Note 2) _ _ 0 D Bus voltage (200 V class and 100 V class: +8 V/400 V, 400 V class: +8 V/800
25 4000 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 32 5000 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 40 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 50 6000 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 63 Note1) Contact P/A in case of a stroke length beyond the maximum.
355 427 IDF240D JIS 10K FF 100 (4B) Flange 770 1550 1640 385 703 730 700 800 355 592 The auto drain is enclosed in the same shipping package as the main body.
0.2 0.2 0.1 0.1 0.196 0 200 400 600 800 1000 1200 1400 0 0.2 0.1 0.3 0.4 0.6 0.5 0.8 0.7 0.9 1.0 1000 0 200 400 600 800 Flow rate (L/min (ANR)) Supply pressure P1 (MPa) Relief flow rate (L/min (ANR)) 817 IR1000/2000/3000 Series IR3000 Series The operating conditions or external disturbance may affect each of the characteristics.
BZ C D E1 F1 GA GB H H1 I J K KA M MM NA S ZZ 20 to 350 1/8 18 15.5 13 7 M4 x 0.7 9 16.5 8 15 3 18 12 35 5 31 M4 x 0.7 depth 7 5 6 3 M8 x 1.25 29 83 118 25 to 400 1/8 22 19.5 17 8 M5 x 0.8 9.5 18.5 10 17 3 18 12 40 6 33 M5 x 0.8 depth 8 5.5 8 3.5 M10 x 1.25 29 83 123 32 to 450 1/8 22 19.5 17 8 M5 x 0.8 9.5 20 12 19 3 18 12 40 6 38 M5 x 0.8 depth 8 5.5 10 3.5 M10 x 1.25 35.5 85 125 40 to 800
CY Stroke length tolerance Up to 1000 mm, Up to 1500 mm 80, 100 Basic style, Axial foot style, Rod side flange style, Head side flange style, Clevis integrated style MQQ M JIS Symbol Double acting, Single rod Mounting RHC Standard Stroke MK(2) Standard stroke Long stroke Note) Bore size (mm) RS Q G 20 25, 50, 75, 100, 125, 150, 200 201 to 350 25 301 to 400 RS H A 32 301 to 450 40 301 to 800
PW Width across flats KA LZ PH GB Width across flats B1 MM E RY BF FY D e C B N BN H1 C B RT AL A K FT ZZ + l + Stroke h + l FX FZ S + Stroke M H ZZ + Stroke [mm] Bore size [mm] Stroke range [mm] A AL B B1 BF BN BP BQ C D E GA GB GC GD GL GR H1 J K KA LZ Without rod boot With rod boot 40 Up to 800 20 to 800 30 27 60 22 71 96 1/4 1/4 44 16 32 85 15 26 54 10 10 8 M8 x 1.25 6 14 71 50 Up to
Inlet pressure (MPa) 14-20-38 3 Super Mist Separator Series AME Construction Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Component Parts Note: Refer to page 14-20-59 for How to Order Bowl Assembly. No.
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Drain cock: Gray One-touch fitting N.C. auto-drain not available for AMG650.
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 2. Discharge the drainage on a regular basis.
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Single acting 6-2-4 5, 10, 15, 20 MB MB1 How to Order/Double Acting CA2 CJ1B 4 5 U4 CS1 C76 Applicable tubing Mounting style C85 Tubing material Size O.D. 4 mm 4 mm Basic style B Symbol Bore size 2.5 mm 2.5 mm Polyurethane Soft nylon Bore size 4 C95
800 2m/s 2m/s 1000 1000 3) Flow rate : 250L/min 6) Flow rate : 180L/min 75 50 25 0 25 50 75 Installation distance from ionizer to workpiece [mm] 75 50 25 0 25 50 75 -75 -50 -25 0 25 50 75 -75 -50 -25 0 25 50 75 0 0 mm ionizer to workpiece [mm] Installation distance from mm 200 200 20m/s 400 400 2m/s 20m/s 2m/s 600 600 10m/s 800 800 10m/s 5m/s 1000 1000 1200 5m/s 1400 5-4.
H5 Initial power / Power consumption (W) 100 VAC 200/40 400/70 400/80 600/130 800/180 200 VAC 800/40 1600/80 1600/80 2400/130 3200/180 Note 1) Initial power and power consumption are nominal values. Note 2) Heaters are not available for size 16.
/40 800/50 XL1A25-60S-1 XL1A25-60S-2 XL1A25-60S-2 1 1 1 H5 AC100V 200/40 400/70 400/80 / AC200V 800/40 1600/80 1600/80 XLA-63-2 XLA-80-2 AC90240V XL1A25-60S-2 XL1A25-60S-3 1 1 H4 AC100V 400/100 600/150 / AC200V 1600/100 2400/150 XL1A25-60S-3 XL1A25-60S-2 1 2 H5 AC100V 600/130 800/180 / AC200V 2400/130 3200/180 1[W] 216 PTC 200V PTC 200 150 100V PTC 0 5 10
H5 Initial power / 100 VAC 200/40 400/70 400/80 600/130 800/180 Power 200 VAC 800/40 1600/80 1600/80 2400/130 3200/180 consumption (W) Note 1) Initial power and power consumption are nominal values. Note 2) Heaters are not available for size 16.