Plug Part Number Bore size [mm] Part number Port thread type Quantity 12 (10 x 2) 16 (12 x 2) P-M3 M3 8 20 (16 x 2) 25 (20 x 2) 32 (25 x 2) P-M5 M5 8 P-R1 Rc1/8 8 40 (32 x 2) 50 (40 x 2) 63 (45 x 2) P-N1 NPT1/8 8 P-G1 G1/8 8 P-R2 Rc1/4 8 80 (56 x 2) 100 (71 x 2) P-N2 NPT1/4 8 P-G2 G1/4 8 * 1 set includes 8 pieces.
L X P Table displacement (m) Table displacement (m) LXPB-200 LXPB-200 1500 1500 LXPB-175 LXPB-175 1000 1000 LXPB-150 LXPB-150 LXPB-125 LXPB-125 LXPB-100 LXPB-100 500 500 LXPB-75 LXPB-75 LXPB-50 LXPB-50 0 Weight (kg) 0 Weight (kg) 1 2 3 4 5 6 1 2 3 4 5 6 Displacement at the section indicated by the arrow when a load is applied to this section with the slide table fully extended.
Unit switching Real-time switch output ( ) For air Hysteresis mode Display Real-time flow rate l/min Accumulated flow l ON YES CFM x 10-2, CFM x 10-1 ft3 x 10-1 OFF P-1 P-2 High flow rate CFM=ft3/min "P" Window comparator mode H : Hysteresis High Flow Rate Type (For Air) H H Display Real-time flow rate l/min Accumulated flow l, m3, m3 x 103 ON NO OFF P-1 P-2 ft3, ft3 x 103, ft3 x 106 CFM
Unit switching Real-time switch output ( ) ZSE ISE For Air Hysteresis mode Display Real-time flow rate l/min Accumulated flow l ON PSE YES CFM x 102, CFM x 101 ft3 x 101 OFF P-1 P-2 High flow rate Z I SE3 CFM = ft3/min P Window comparator mode H: Hysteresis High Flow Rate Type (For Air) PS H H Display Real-time flow rate l/min Accumulated flow l, m3, m3 x 103 ON Z I SE1 2 NO OFF P-1 P-
Note 13) When D is selected, select P for (8) Options for the single unit model. Cannot be selected when (4) Wiring is N.
Swivel Elbow KFG2V Metric Inch P. 324 P. 329 Metric Inch P. 325 P. 331 KDM KB KR KA KQG2 Straight Union KFG2H Female Connector KFG2F KG Metric Inch P. 324 P. 330 Metric Inch P. 326 P. 331 KFG2 KFG2 MS KKA KP LQ Union Tee KFG2T Union Nut KFG2N MQR Metric Inch P. 324 P. 330 Metric Inch P. 326 P. 331 T IDK 321 Stainless Steel 316 Insert Fittings Applicable Tubing: Metric Size, Connection Thread
B C SMC A B E L J B 2 x P 2 x F K Body material: PFA N G A D L K 4 x M Non-locking type Locking type 60 (H1) (H2) C A B SMC E J B 2 x P (mm) Dimensions D G E C M P N L K J H2 F H1 B A Model Body material LVH20 LVH30 LVH40 LVH20 LVH30 LVH40 LVH20 LVH30 LVH40 M5 x 0.8 10 10 54.5 Rc 1/8, 1/4, NPT 1/8, 1/4 27 22 22 76.5 75 33 30 (SUS) Stainless steel 19 13 81 Rc 1/4, 3/8, NPT 1/4, 3/8 37
= (P P) MPa Viewing the graph To generate a water flow of 4l/min at a differential pressure of 0.1MPa, an effective area with Cv factor 0.28 (VDW303) or more is required.
T IDU22,37E-30-T IDU55E-30-T GFCI For Option R GFCI Operation Failure For Option R Operation Failure 1 2 3 TB TB MC1 TDR TDR MC1 PRR PRR MC1THR THS MC1 PRR CM MC1 MC2 MC1 FM1 CM TDR FM2 MC1 THP2 THP1 THS MC1 For Option M MC2 FM2 MC2 PRS1 P MC1 TDR TDR PRS2 THR PRR FM1 MC2 P PRS P For Option M SYMBOL DESCRIPTION IDU75E-30-T CM Refrigerating Compressor GFCI For option R Operation Failure
Inlet 77 154 235 12.5 31 62 125 250 375 625 725 900 1190 100 150 227 320 400 IDG100L-N04-P IDG100S-N04-P IDG100-N04-P IDG30L-N03-P IDG50L-N03-P IDG60L-N04-P IDG75L-N04-P IDG60S-N04-P IDG75S-N04-P IDG3-N02-PS IDG5-N02-PS IDG10-N03-P IDG20-N03-P IDG30-N03-P IDG50-N03-P IDG60-N04-P IDG75-N04-P IDG1-N02-P The membrane air dryer uses hollow fibers composed of a macro molecular membrane through
Blanking plug LQ P 07 2 Packaging Nil 1 Clean packaging Class M3.5 Standard packaging Class M5.5 Used to block fittings which are not being used.
The voltage (across P-N or P+-N-) of the main circuit converter is displayed. 0 to 900 V -74- 6. CC-Link setting CC-Link function of the driver. Wiring and PLC setting must to satisfy the specifications.
The voltage (across P-N or P+-N-) of the main circuit converter is displayed. 0 to 900 V -79- 6. CC-Link setting CC-Link function of the driver. Wiring and PLC setting must to satisfy the specifications.
When the switch point of the display value = 75 with ISA3-H The weight is 50, so X = 25. In window comparator mode, error output, switch output off The boundary value is fixed.
P Ps Note 4, 5) NG NG Check kinetic energy. E Es ) Ps: Allowable pressure Refer to page 1498. ) Es: Allowable kinetic energy Refer to page 1498. OK OK Model determination Note 1) Stroke adjustment with either a bumper bolt or adjustment bolt is considered as an intermediate stop.
S 55 58 60 74 75 P M5 x 0.8 Rc 1/8 Rc 1/8 Rc 1/4 Rc 1/4 NY 26 28 36 42 46 NX 6 6.5 8 10 11 NC 7.5 depth 4.5 9 depth 5.5 10.5 depth 6.5 13.5 depth 8.5 17 depth 10.5 MM M10 x 1.25 M12 x 1.25 M14 x 1.5 M18 x 1.5 M18 x 1.5 NS 43 45 44 54 53 N 14 15.5 16 21.5 21.5 KA 10 12 14 18 18 ND M5 x 0.8 M6 x 1 M8 x 1.25 M10 x 1.5 M12 x 1.75 NE 4.3 5.1 6.9 8.7 10.5 ZZ 69 72 75 92 96 Model MUB25 MUB32 MUB40
Bore size Standard stroke (mm) 40 30, 50, 75, 100 63 30, 50, 75, 100 100 30, 50, 75, 100 Applicable auto switches Lead wire length (m) Load voltage Auto switch model no.
S 55 58 60 74 75 P M5 x 0.8 Rc 1/8 Rc 1/8 Rc 1/4 Rc 1/4 NY 26 28 36 42 46 NX 6 6.5 8 10 11 NC 7.5 depth 4.5 9 depth 5.5 10.5 depth 6.5 13.5 depth 8.5 17 depth 10.5 MM M10 x 1.25 M12 x 1.25 M14 x 1.5 M18 x 1.5 M18 x 1.5 NS 43 45 44 54 53 N 14 15.5 16 21.5 21.5 KA 10 12 14 18 18 ND M5 x 0.8 M6 x 1 M8 x 1.25 M10 x 1.5 M12 x 1.75 NE 4.3 5.1 6.9 8.7 10.5 ZZ 69 72 75 92 96 Model MUB25 MUB32 MUB40
mode] In the 3 step setting mode, the set value (P or n) and hysteresis (H) can be changed.
P K K 8 U 57 (at knob locked) DIN rail part no.