water for welding gun Main line flow control The accumulated pulse output function (100 l/pulse) enables remote monitoring of accumulated flow. 100 l/pulse M/C A COM COM COM B DC12V GND F.G.
B 100 31.8 29.3 27.8 69.9 10.7 3/4-16 208.9 80 and 100mm-X165US are a future release.
Dryer Capacity Model A B C D E F B IN PUT IDF1D-1 to 11C-1 IDU3D-1 to 11C-1 4.2 x 7 (Long hole) Single phase Single turn 110VAC (50Hz) 110 to 120VAC (60Hz) 100VAC (50Hz) 100 to 110VAC (60Hz) 500VA 78 94 100 64 75 1.5 IDF-TR500-1 E D 4-F IDF15C-1 IDU15C-1 4.2 x 9 (Long hole) Input cord 2m 1kVA 104 122 134 75 114 4 IDF-TR1000-1 IDF-TR -2 C A OUT PUT Weight (kg) Primary voltage Secondary voltage
VA PE R H T 2 x P D GC GB S Q 2 x P (Plug) GA JC PD GD FB C + Stroke FA G K J A + Stroke [mm] Bore size Standard stroke A C D FA FB G GA GB GC GD H J JC K L MM ML NN 80 (56 x 2) 25, 50, 100 150, 200 85.5 62 25 19.5 4 69 28.5 20.5 25 22 202 34.5 15.5 34.5 50 M12 x 1.75 30 M10 x 1.5 100 (71 x 2) 94.5 66 30 23.5 5 84 31 20 28.5 21.5 240 42 17.5 42 62 M14 x 2 35 M12 x 1.75 Bore size OA OB OL
Double knuckle joint (With pin) Rod end nut Calculation: (Example) CNSL140-100 Basic weight 40.19 (Foot style, 140) Additional weight 1.96/100 stroke Cylinder stroke 100 stroke 40.19 + 1.96 x 100/100 = 42.15 kg Construction Principle Spring locking (Exhaust lock) The spring force which acts upon the taper ring is magnified by a wedge effect, and is conveyed to all of the numerous steel
N S NBR Silicon rubber 40 50 40 50 57 86 160 224 Pad type 63 63 80 80 U Urethane rubber H Heavy duty F Fluoro rubber 100 100 E EPR Add NBR weight to the table on the right for other materials. 125 125 Dimensions ZP H 40 50 ZP H 63 80 ZP H 100 125 (mm) (mm) (mm) Model A 63 ZP63H B 65 80 ZP80H 82 C 14.5 16.5 D 50 61 Y 3.5 4.5 Model A 40 ZP40H B 42 50 ZP50H 52 C 32 42 Model A 100 ZP100H B 103
(mm/s) : Distance to the load's center of gravity (m) : Dynamic moment (Nm) : Gravitational acceleration (9.8m/s) m FE ME L1 3 1.4 100 1 3 Note 4) a is a dimensionless coefficient for calculating impact force.
Ground the F.G. cable with a resistance of 100 or less +24 V Brown + 24 VDC +24 V Blue 0 V Power supply 24 VDC 0 V F.G.
Measurement circuit of cylinder output relative to supply pressure CQ2B40-75D (Standard) CQ2XB40-75D (Low speed cylinder) RE A B [Example of test method] The test sample is in place in an acrylic chamber. The chamber is set up on a Class 100 clean bench. The solenoid valve is operated while supplying a volume of clean air equal to the intake volume of a laser dust monitor (28.3 l/min).
Measurement circuit of cylinder output relative to supply pressure CQ2B40-75D (Standard) CQ2XB40-75D (Low speed cylinder) RE A B [Example of test method] The test sample is in place in an acrylic chamber. The chamber is set up on a Class 100 clean bench. The solenoid valve is operated while supplying a volume of clean air equal to the intake volume of a laser dust monitor (28.3 l/min).
The following graphs show the displacement at point A, which is 100 mm apart from the center of rotation, where the load is applied.
HS 8.5 SMC SMC SMC SMC 16 16 A 29 Auto switch B A 26 Auto switch B (36) D-B5/B6/B59W type 20 to 40 D-G5NTL type 20 to 40 50 to 100 50 to 100 Approx. HS Approx. HS 12 12 SMC SMC 24.5 24.5 A 33 B A 33 Auto switch B D-C73C/C80C type 20 to 40 D-H7C type 20 to 40 50 to 63 50 to 63 Approx. HS Approx.
200 300 500 700 Average speed Va mm/s A, A Stroke (mm) A A A A 20 14.5 16.5 21 27 29.5 35.5 Model 150 56.5 64 125 42.5 55 64 100 34 42.5 53.5 50 75 28.5 34 33 37.5 43 50 18.5 28 25 30 33.5 43 40 18.5 20.5 25 27 29.5 35.5 30 14.5 18.5 21 27 29.5 35.5 10 14.5 16.5 21 27 29.5 35.5 Allowable moment coefficient: Graph 2 MXQ 6 MXQ 8 MXQ12 MXQ16 MXQ20 MXQ25 6 7 9 10.5 14 16.5 13.5 16 19.5 24.5
200 300 0 100 200 300 0 100 200 300 0 Detection distance (m) Detection distance (m) Detection distance (m) Ex. 1) To detect 300 m, select a 1.0 detection nozzle and supply pressure of 0.2 MPa.
Single vane type Double vane type , 0 5 Chamfer +4 0 a a r r n n 9 0 n n e g g 0 o o g e e i i n t t 1 2 a a 0 a 8 7 t t r o o 1 +4 0 0 0 n R R o e +4 0 +4 0 i t g 0 a n 9 t o a e r R g n n o a ti r a n t o o R ti a t o R Chamfer Chamfer Chamfer Chamfer A port B port A port B port A port B port A port B port For size 40 actuators, a parallel keyway will be used instead of chamfer.
The switch may be damaged if a screw other than the one supplied, is used. 100 A or less at 24 VDC Leakage current 0.8 mA or less Operating position . Red LED lights up Optimum operating position .
One-touch fitting One-touch fitting A A 58 Applicable tube O.D.
Standard Strokes Symbol Rubber bumper Bore size [mm] Standard stroke [mm] 12 (10 x 2) 16 (12 x 2) 10, 20, 30, 50, 100 20 (16 x 2) 25 (20 x 2) 20, 30, 50, 100, 150 32 (25 x 2) 40 (32 x 2) 50 (40 x 2) 63 (45 x 2) 80 (56 x 2) 100 (71 x 2) 25, 50, 100, 150, 200 Intermediate strokes are available as a special order. Refer to pages 10 and 11 for cylinders with auto switches.
Set of long clamping screws ZH2-TB203-A 3 M4 x 70 2 pcs. ZH13DA ZH15DA ZH2-TB204-A 4 M4 x 90 2 pcs. ZH2-TB206-A 6 M4 x 130 2 pcs. Hexagon nut (M4) 2 pcs. ZH2-TB208-A 8 M4 x 170 2 pcs. (ZH2-TB201-A)3 1 M4 x 30 2 pcs. Flat washer (for M4) 2 pcs. ZH2-TB302-A 2 M4 x 55 2 pcs. ZH2-TB303-A 3 M4 x 80 2 pcs. ZH18DA ZH20DA ZH2-TB304-A 4 M4 x 100 2 pcs. ZH2-TB306-A 6 M4 x 145 2 pcs.
Bore size/ Standard stroke (mm) Auto switch Nil Without auto switch (Built-in magnet) Auto switches are shipped together (not assembled). 40 63 100 30, 50, 75, 100 30, 50, 75, 100 30, 50, 75, 100 A + Stroke B + Stroke Dimensions (mm) A B GB Bore size (mm) 40 63 100 58 48.5 36.5 GB 73 61.5 38 78 66.5 38 Dimensions other than the above are the same as standard products.