Electrical entry TT is approved for Class I, II, III, Division 1, Groups A, B, C, D, E, F, G. Electrical entry L and LL is approved for Class I, Division 1, Groups A, B, C, D. 4.

Auto Switch Proper Mounting Position (Detection at Stroke End) Solid state auto switch D-M9 Reed auto switch D-A93 C B A Lead wire, in-line entry Values in the table below are used as a reference when mounting the auto switches for stroke end detection. For actually setting the auto switches, adjust them after confirming their operation.

Auto Switch Proper Mounting Position (mm) Auto switch model D-M9 D-M9W D-A9 Bore size A A B B 20 25 32 40 10.5 9.5 6.5 5.5 10.5 9.5 6.5 5.5 11.5 10.5 7.5 6.5 17.5 15.5 13.5 11.5 Note) The above-mentioned value is a guide for auto switch mounting positions for stroke end detection.

Press the "UP"and "DOWN"buttons to change the set value. d. Press the "SET"button. d. Press the "SET"button. The set value will light up. The set value will light up. * When the set value is flashing, it is not registered. * When the set value is flashing, it is not registered.

Panel mount adapter ZS-46-B Panel mount adapter + Front protection cover ZS-46-D Lead wire with connector ZS-46-3L 3-core, 2 m, Non-waterproof (Without waterproof cover) Front protection cover ZS-27-01 D Panel mount adapter + Front protection cover ZS-46-D R1/8 Piping adapter ZS-46-N1 NPT1/8 Piping adapter ZS-46-N2 9 3-Screen Display High-Precision Digital Pressure Switch ZSE20(F)/ISE20

1 x 4 1.1 x 8 R 1/4 R 1/4 R 1/4 R 1/4 14 14 14 14 20 20 20 20 14 14 14 14 D 2 A Connection thread H1 L1 Copper extension nozzle: KNL (mm) Model Nozzle size D Outside diameter L1 Outside diameter KNL3-06-150 KNL3-06-200 KNL6-06-150 KNL6-06-200 1.5 2 1.5 2 6 6 6 6 300 300 600 600 D L1 Note) When a copper extension nozzle is ordered separately, a self-align fitting will also be required for

Wiring Electrical entry Auto switch type Electrical entry from inside 3-wire D-F9P B Solid state switch D-F9 In-line 2-wire D-F9B 3-wire D-F9NW,D-F9PW In-line 2 color indication solid state switch D-F9 W 2-wire D-F9BW 3-wire D-F9NWV,D-F9PWV Perpendicular B 2-wire D-F9BWV Install auto switch as shown in figure below.

, A90V D-A93, A93V D-A96, A96V Series CQSW Basic Non-rotating Rod 12 16 5, 10, 15, 20 25, 30 How to Order . 1 Construction . 9 20 25 5, 10, 15, 20 25, 30, 35, 40 45, 50 12, 16 20, 25 Dimensions ...10 &11 Series CQS How to Order . 1 12 16 20 25 5, 10 Construction . 12 Solid state switch D-M9N, F9NV D-M9P, F9PV D-M9B, F9BV D-F9NW, F9NWV D-F9PW, F9PWV D-F9BW, F9BWV Dimensions ...13 to 16 Series

63 80 100 MGTL D-Y5 type D-Z7 type Note 1) Note 1) D-Z8 type D-A9 type D-F9 type D-Y6 type D-Y7 type Note 1) Vertical outlet types cannot be mounted.

Note Weight Bracket LFE-1-D Tapping screw for LFE1 (3 x 10), 4 pcs. Approx. 45 g LFE-2-D Tapping screw for LFE2 (3 x 10), 4 pcs. Approx. 70 g LFE-3-D Tapping screw for LFE3 (3 x 10), 4 pcs. Approx. 70 g 3 3-Color Display Electromagnetic Digital Flow Switch LFE Series For the flow switch precautions, refer to the Operation Manual on the SMC website.

Auto Switch Proper Mounting Position (Detection at Stroke End) D-A93 12 16 to 25 A B W A B W D-M9B/M9N 12 16 to 25 A B W A B W B D-A93 B D-M9B/M9N/M9P Bore size (mm) A 11.5 W 4 A 15.5 W 5.5 12 16 20 25 0.5 4.5 12 0 4.5 16 4 6 16 3.5 1 20 7.5 2.5 17 5.5 -1 21 9.5 0.5 Specific Product Precautions Be sure to read this before handling. Mounting Caution 1.

Description Material Note Aluminum cast Aluminum cast STKM Painted silver Painted silver Painted silver Top cover Bottom cover Bowl q w e 1.17-13 Auto Feed Lube ALF400 to 900 Dimensions: Auto Feed Lube ALF400 ALF800/900 AC AV AU AF AR ALF500/600 IR VEX AW AMR AWM Model Port size AWD D A B C 80 85 90 100 100 100 238.5 246.5 295.5 319.5 338.5 344.5 44 46 48 51 59 63 ALF400 ALF400-06 ALF500

Configuration One thermo-chiller for one master. 2 2 R D R D 3 3 S D S D 5 5 S G S G Master This product Do not connect any wire to other PIN numbers. Fig. 3-13 Connection of RS-232C HRL Series 3.3 Installation 3-27 HRX-OM-W060 Chapter 3 Transport and Setting Up 3.4 Piping Connect piping firmly.

Configuration One thermo-chiller for one controller. 2 2 R D R D 3 3 S D S D 5 5 S G S G Controller Master This product Do not connect any wire to other PIN numbers. Fig. 3-13 Connection of RS-232C 3.3.10 Ethernet Modbus/TCP Communication wiring This product can operate the following by Ethernet Modbus/TCP communication.

Configuration One thermo-chiller for one master. 2 2 R D R D 3 3 S D S D 5 5 S G S G Master This product Do not connect any wire to other PIN numbers. Fig. 3-14 Connection of RS-232C 3.3.10 Ethernet Modbus/TCP Communication wiring This product can operate the following by Ethernet Modbus/TCP communication.

, 700, 800 25 4000 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 32 5000 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 40 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 50 6000 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 63 Note1) Contact P/A in case of a stroke length beyond the maximum.

When P2 + 0.1 b, choked flow P1 + 0.1 293 Q = 600 x C (P1 + 0.1) (1) 273 + t When P2 + 0.1 > b, subsonic flow P1 + 0.1 2 P2 + 0.1 b P1 + 0.1 Q = 600 x C (P1 + 0.1) 1 (2) 1 b 293 273 + t Q : Air flow rate [dm3/min (ANR)], dm3 (Cubic decimeter) of SI unit are also allowed to described by l (liter). 1 dm3 = 1 l .

Number of ejectors 1 to 10 Ejector mounting position U D U side D side [Example: When individual wiring type model 45 for SY3000 is selected] ZZY Y3-45-04D-C6J1U 1SET Note 1) The combined total of solenoid valve and ejector valve stations is a maximum of 20 stations. (Example: When there are 12 solenoid valve stations, there are 8 ejector stations.)