Endian type Upper communication protocol Big-Endian type Such as PROFIBUS and PROFINET Little-Endian type Such as EtherNET/IP, EtherCAT and CC-Link IE Field. -71No.PF-OMA1011-A Measurement and setting range Rated flow range Display/settable range Applicable products Range Unit A to B C to D Flow L/min 0.50 to 4.00 0.35 to 4.50 4 L Flow gal/min 0.13 to 1.06 0.09 to 1.19 PD 125 to 1000 88 to
Models Standard strokes (mm) 32 40 50 63 MGP 25, 50, 75, 100, 125, 150, 175 200, 250, 300, 350, 400 M L Intermediate strokes (in 5mm increments) are produced by installing spacers of 5, 10, 15 and 20mm widths. When a special intermediate stroke body is needed, contact SMC.
Configuration One thermo-chiller for one master. 2 2 R D R D 3 3 S D S D 5 5 S G S G Master This product Do not connect any wire to other PIN numbers. Fig. 3-15 Connection of RS-232C HRS Series 3.3Installation 3-27 HRX-OM-S004 Chapter 3 Transport and Setting Up 3.4 Piping Piping port size Connect piping firmly.
Series ASD * * * F-D Dual Speed Controller Adjustable by Flat Head Screwdriver with One-touch Fitting. Specifications. How to Order . Construction.
Two mounting styles Table traveling accuracy C D Bottom mount Top mount Model Traveling accuracy C side against A side D side against B side LG1H 0.1 or less 0.1 or less A B Variations Mounting orientation Lead screw type Motor type Guide type Motor/Screw connection Series Standard motor [Tamagawa Seiki Co., Ltd.]
Solenoid on side A 0 2 4 6 8 16 28 30
Side D Side U (SI unit side) Communication connector Output No. 1 3 5 7 9 17 29 31 Solenoid on side B Accessories M12 5-pin Plug A-code 7 5 7 5 Bit No. 1 1 1 3 No. Description Function Valve manifold 2 3 SV24 V 1 +24 V for valve : Output numbers are assigned to stations from side D to U of manifold in order.
Operating time 20 s 30 s Voltage 10 s 5 s Min. 2 s dV dt 1 s = Voltage increase ratio 0.5 s dV 0.2 s 0.1 s Time 0.05 s 0.02 s dt 0.01 s 100 125 200 300 500 400 600 700 1000 2000 3000 4000 1500 < For option B [With earth leakage breaker]> 3. This product is installed with a breaker with the following operating characteristics.
Lube Unit Mounting thread M12 Float switch mounting position J (Bracket mounting dimensions) Panel (Option) Bracket (Option) A B C D E F G H J K L M N P Q R S Model Port size ALDU600-06 ALDU600-10 ALDU900-12 ALDU900-14 ALDU900-20 43 10 57 51 16 67 77 85 90 100 283 296 424 424 476 4 3 135 345 460 145 90 150 480 20 430 470 175 87.5 30 62.5 1 1 1 2 615 615 682 419.2 209 4 1 250 125 33.2 33.2
5 is attached. 1045 AL800/900 Series Dimensions Semi-standard AL800/900 Metal bowl Metal bowl Port size D A B B B C B Maintenance space E IN OUT Metal bowl with level gauge With drain cock Semi-standard/Dimensions B Model Metal bowl Metal bowl with level gauge AL800 AL900 Model Port size With drain cock 297 303 306 312 D A B C E AL800 AL900 286 292 125 125 1 , 1 2 100 100 286 292 59 63 1
D Not available at 80 and 100. Note) Mounting brackets are not mounted and are supplied loose at the time of shipment.
Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: [Included] Presence (Only Rod Side), Cushion: Air cushion, Operating Pressure(MPa): 0.15 to 1.0, Specification: Built-in magnet, Port
Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: [Included] Presence (Only Rod Side), Cushion: Air cushion, Operating Pressure(MPa): 0.15 to 1.0, Specification: Built-in magnet, Port
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 0.7, Specification: Built-in magnet, Auto Switches: M9BW, Lead Wire Length(m): 3, The number
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 0.7, Specification: Built-in magnet, Support bracket: With auto switch mounting bracket,
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: [Included] Presence, Cushion: Air cushion, Operating Pressure(MPa): 0.15 to 1.0, Specification: Built-in magnet, Port thread type: Rc,
Magnet: D (Built-in), Mounting: L (Foot), Bore Size: 25mm, Stroke: 125mm, Rod End Thread: Male Thread, Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire, Horizontal, Lead Wire or Prewired Connector: L (3m), Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting Bracket: C (Auto Switch Mounting Bracket)
Bore Size: 25mm, Port Type: Rc (PT), Stroke: 125mm, Lock Position: R (Front Lock), Manual Override: N (Non-locking Type), Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire, Horizontal, Lead Wire or Prewired Connector: L (3m)
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, End Locking: [Included] Presence, Cushion: Rubber Bumper on Both Ends, Port thread type: Rc, Auto Switches: M9BW,
The MGP is designed for high side load applications found in material handling, lifting and stopping. The cylinder utilizes an ultra-compact design by incorporating the cylinder body as part of the guide body. As the stroke length increases, so does the bearing length, thus enhancing the cylinders load bearing capacity. Conventional designed guided cylinders have a set bearing length resulting