.: 23 (Ø3.2), Port Size/Applicable Tube: 01 (R1/8 Thread), Sealant: S (Sealant)
Actuation: 1 (2 Position Single), Piping/EXH: 43 (Base Mounted), Coil Specification: Standard, Voltage: 5 (24 VDC), Electrical Entry: G (Grommet, Lead Wire 300mm), Light/Surge Voltage Suppressor: S (w/Surge Voltage Suppressor), Manual Override: Non-locking Push Type, Port Size: 01 (1/8 w/Sub-plate, Piping 23 w/o Sub-plate), Thread: N (NPT)
._3d_items_collection = {}; } SMC AN110-01 muffler 1/8 pt, AN SILENCER $4.20 + Add to Quote Add To Cart Add to Cart SMC AXT100-DR-12 din rail, VV5Q* MANIFOLD VQ 4/5 PORT***
Body Size: 2 (1/8, 14), Type: 2 (Elbow), Control Type: 0 (Meter-out), Model: 1FSG, Thread: N (NPT), Port Size: 01 (1/8), Width Across Flats: 9 mm (or None: Sizes 2/3/4), Applicable Tubing: 23 (ø3.2), Seal: S (with Sealant)
AS: AS, Size: 2 (1/8, 1/4 Basis), Style 1: 2 (Elbow), Control Type: 0 (Meter-out), Thread: M5, 10-32UNF, R, Port Size: 01 (1/8), Tube Size: 23 (Ø3.2), Option: S (Sealant), Lock Nut: J (Round)
.: 23 (ø3.2), Port Size/Applicable Tubing O.D.: 01 (R1/8, Rc1/8), Thread Material/Surface Treatment: A (Brass), Sealant: P (Face Seal)
.: 23 (ø3.2), Port Size/Applicable Tubing O.D.: 01 (R1/8, Rc1/8), Thread Material/Surface Treatment: A (Brass), Sealant: P (Face Seal), Release Button: 1 (Oval Type)
.: 23 (ø3.2), Port Size/Applicable Tubing O.D.: 01 (R1/8, Rc1/8), Thread Material/Surface Treatment: A (Brass), Sealant: P (Face Seal)
Body Size: 2 (1/8, 1/4), Type: 2 (Elbow), Control Type: 0 (Meter-out), Indicator Direction: 0°, Thread: R, Port Size: 01 (1/8), Applicable Tubing O.D.: 23 (ø3.2)
If the error cannot be solved after the instructions above are performed, please contact SMC for investigation. 23 Function Details PFG300 Series Copy function The settings of the master monitor can be copied to the slave monitors, reducing setting labor and minimizing the risk of setting mistakes. The set value can be copied to up to 10 flow monitors simultaneously.
Item CH2 measured value: 16-bit signed integer Bit offset 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33 32 Item CH32 measured value: 16-bit signed integer Bit offset 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 Item CH4 measured value: 16-bit signed integer Bit offset 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Error diagnosis CH4 diagnosis CH3 diagnosis CH2 diagnosis CH1 diagnosis Reservation
Note) 4 6 8 10 12 23 04 06 08 10 12 3.2 TMH-23J TMH-04J TMH-06J ASV Body size AS1001F AS2001F AS2051F AS3001F AS4001F AK TMH-06 TMH-08 ASS TMH-10 TMH-12 Applicable tubing Inch Size ASR Note) Mounting bracket is not available. This is an application example. Applicable tubing size ASF 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" 1/2" 01 03 05 07 09 11 13 Can be mounted on the panel.
Note) Inch size Metric size KE 23 01 1 8" 3.2 4 6 8 10 12 5 32" Control type 04 06 08 10 12 03 05 07 09 11 13 3 16" Meter-out Meter-in 0 1 AS-FG 1 4" 5 16" AS-FP 3 8" 1 2" With One-touch fitting AS-FM Note) For applicable tubing O.D. selection, refer to the Model on page 630. Use 1/8" tube.
10 10 12 12 01 1/8" 03 5/32" 07 1/4" 09 5/16" 11 3/8" 13 1/2" -X214 Restrictor (Without check valve) With One-touch ttings Example) AS2002FS-04-X214 With indicator 10Clean Series 1 For selecting applicable tubing O.D., refer to the Model shown above. 2 Use 1/8" tubing.
Without nozzle KN-R02-100 KN-R02-150 KN-R02-200 KN-R02-250 VMG1-R02-300 VMG1-R02-350 VMG1-R02-400 KNH-R02-100 KNH-R02-150 KNH-R02-200 KNS-R02-075-4 KNS-R02-090-8 KNS-R02-100-4 KNS-R02-110-8 01 02 03 04 05 06 07 11 12 13 21 22 23 24 1 1.5 2 2.5 3 3.5 4 1 1.5 2 0.75 x 4 0.9 x 8 1 x 4 1.1 x 8 Connection size Piping connection method Symbol Size and model no.
Body Size: 20, Thread: N (NPT), Port: 01 (1/8), Option: E [Square embedded type pressure gauge (with limit indicator)], Attachment: Standard, Semi-Standard 1: 23 (2 + 3), Semi-Standard 2: NZ (N + Z)
Body Size: 20, Thread: Rc, Port: 01 (1/8), Option: Standard, Attachment: Standard, Semi-Standard 1: 23 (2 + 3), Semi-Standard 2: Standard
Body Size: 20, Thread: N (NPT), Port: 01 (1/8), Option: CE (C + E), Attachment: K (Check Valve), Semi-Standard 1: 23 (2 + 3), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, and Pressure Gauge: psi, °F)
Body Ported), Voltage: 5 (24VDC), Electrical Entry: G (Grommet), Orifice Size: 23 (2.3mm), Port Size: 01 [Base Mount w/Sub-Plate 1/8(6A) or Body Ported 1/8(6A)], Thread Type: T (NPTF)
Body Ported), Voltage: 5 (24VDC), Electrical Entry: G (Grommet), Orifice Size: 23 (2.3mm), Port Size: 01 [Base Mount w/Sub-Plate 1/8(6A) or Body Ported 1/8(6A)], Thread Type: T (NPTF), Body/Seal Material: H (Body SUS, Seal FKM)