SMC Corporation of America
Elite Part Number Search
Search Results "21-VQ1200-5"

Actuation: 2 (2 Position Double), Seal: 0 (Metal Seal), Function: Standard (0.4W DC, AC), Coil Voltage: 3 (110VAC 50/60Hz), Light/Surge Suppressor: Yes, Manual Override: B (Locking, Tool Required)

Actuation: 2 (2 Position Double), Seal: 0 (Metal Seal), Function: Standard (0.4W DC, AC), Coil Voltage: 1 (100VAC 50/60Hz), Light/Surge Suppressor: Yes, Manual Override: D (Slide Locking, Manual)

Actuation: 2 (2 Position Double), Seal: 0 (Metal Seal), Function: Standard (0.4W DC, AC), Coil Voltage: 1 (100VAC 50/60Hz), Light/Surge Suppressor: Yes, Manual Override: Non-locking Push Style (Tool Required)

Actuation: 2 (2 Position Double), Seal: 0 (Metal Seal), Function: Standard (0.4W DC, AC), Coil Voltage: 5 (24VDC), Light/Surge Suppressor: E (None), Manual Override: Non-locking Push Style (Tool Required)

Actuation: 2 (2 Position Double), Seal: 0 (Metal Seal), Function: Standard (0.4W DC, AC), Coil Voltage: 6 (12VDC), Light/Surge Suppressor: Yes, Manual Override: Non-locking Push Style (Tool Required)

Actuation: 2 (2 Position Double), Seal: 0 (Metal Seal), Function: Standard (0.4W DC, AC), Coil Voltage: 5 (24VDC), Light/Surge Suppressor: Yes, Manual Override: Non-locking Push Style (Tool Required)

Actuation: 2 (2 Position Double), Seal: 0 (Metal Seal), Function: Standard (0.4W DC, AC), Coil Voltage: 3 (110VAC 50/60Hz), Light/Surge Suppressor: Yes, Manual Override: Non-locking Push Style (Tool Required)

Actuation: 2 (2 Position Double), Seal: 0 (Metal Seal), Function: Standard (0.4W DC, AC), Coil Voltage: 5 (24VDC), Light/Surge Suppressor: Yes, Manual Override: C (Locking, Manual)

Function 1: Double, Sealant: Metal Seal, Function 2: Standard (1W DC, AC), Coil Voltage: 110VAC 50/60Hz, Light & Surge Suppressor: -, Manual Override: -

Function 1: Double, Sealant: Metal Seal, Function 2: Standard (1W DC, AC), Coil Voltage: 24VDC, Light & Surge Suppressor: Yes, Manual Override: Locking Slotted Style

Function 1: Double, Sealant: Metal Seal, Function 2: Standard (1W DC, AC), Coil Voltage: 12VDC, Light & Surge Suppressor: -, Manual Override: -

Function 1: Double, Sealant: Metal Seal, Function 2: Standard (1W DC, AC), Coil Voltage: 100VAC 50/60Hz, Light & Surge Suppressor: -, Manual Override: -

Function 1: Double, Sealant: Metal Seal, Function 2: Standard (1W DC, AC), Coil Voltage: 24VDC, Light & Surge Suppressor: Yes, Manual Override: Locking Knob Style

Actuation: 2 Position Double, Seal: Metal Seal, Function: Standard (0.4W DC, AC), Coil Voltage: 100VAC 50/60Hz, Light/Surge Suppressor: None, Manual Override: Non-locking Push Style (Tool Required), CE Compliant: -

Actuation: 2 Position Double, Seal: Metal Seal, Function: Standard (0.4W DC, AC), Coil Voltage: 220VAC 50/60Hz, Light/Surge Suppressor: Yes, Manual Override: Non-locking Push Style (Tool Required), CE Compliant: -

Actuation: 2 Position Double, Seal: Metal Seal, Function: Standard (0.4W DC, AC), Coil Voltage: 100VAC 50/60Hz, Light/Surge Suppressor: Yes, Manual Override: Locking, Tool Required, CE Compliant: -

Actuation: 2 Position Double, Seal: Metal Seal, Function: Standard (0.4W DC, AC), Coil Voltage: 110VAC 50/60Hz, Light/Surge Suppressor: Yes, Manual Override: Locking, Tool Required, CE Compliant: -

Actuation: -, Seal: -, Function: -, Coil Voltage: -, Light/Surge Suppressor: -, Manual Override: -, CE Compliant: -

Type: Solenoid Valves, Application: Unit for Manifold Mounting, Mounting Orientation: Manifold Base, Voltage: AC100V, Specification: Standard, Actuation: Double, Status at Power Off: Self-Retaining, Valve Positions: 2-Position Normally Open, Applicable Cylinder Diameter(Ø): -, Pressure Rating(MPa): 1, Driving Type: Pilot Type Spool, Pilot Air Supply: Internal, Seal Type: Standard, Manual

Type: Solenoid Valves, Application: Unit for Manifold Mounting, Mounting Orientation: Manifold Base, Voltage: DC24V, Specification: Standard, Actuation: Double, Status at Power Off: Self-Retaining, Valve Positions: 2-Position Normally Open, Applicable Cylinder Diameter(Ø): -, Pressure Rating(MPa): 1, Driving Type: Pilot Type Spool, Pilot Air Supply: Internal, Seal Type: Standard, Manual Switch