V) 1, 2 0 V 0.1 V 10 V Current output 1 4 mA 4.16 mA 20 mA Models Minimum value of rated flow range Maximum value of rated flow range PFMC7501 5 L/min 500 L/min PFMC7102 10 L/min 1000 L/min PFMC7202 20 L/min 2000 L/min 1: Analogue output accuracy is within 3%F.S. 2: Set the current to the analogue output from the connected equipment to 20 A or less when selecting 0 to 10 V.

74 60 820 263 86 70 0.05 AN300-03 3 8 AN400-04 1 2 0.02 AN500-06 3 4 0.01 AN600-10 1 1 1 0.005 AN700-12 1 4 AN800-14 1 2 AN900-20 0.002 50 200 1000 5000 20 100 500 2000 10 50 10 Construction/Parts/Dimensions Air flow (l/min (ANR)) AN500 to 900 AN200 to 400 Noise Level (Initial conditions) End plate End plate AN200 to 900 Condition: 0.5 MPa at inlet pressure of solenoid valve Measurement

IN Fitting Type Inch size Metric size ARP Common supply block (S) Common supply block with pressure switch (P) Fitting type Fitting type Straight 6 8 10 8 6 10 Elbow Straight 1/4 5/16 3/8 5/16 1/4 3/8 Elbow Symbol Symbol IR-A 01 02 03 13 14 15 51 52 53 63 64 65 5 56 56 5 IR 0.4 0.2 0.6 0.5 SMC 20 MPa 24 20 17 24 56 IRV 0.3 0.1 VEX 32.5 SRH 4.

9 Appendix 9.5.4 Recirculating fluid Pressure Loss Fluid: Water HED003 35 30 Pressure loss kPa 25 HED003-HW13 20 15 10 HED003-HW19 5 0 0 2 4 6 8 10 12 14 16 18 20 Flow rate L/min Fig.9-13 Recirculating fluid Pressure loss (HED003) HED005, HED007 35 30 Pressure loss kPa 25 HED005-HW13 HED007-HW13 20 15 10 HED005-HW19 HED007-HW19 5 0 0 2 4 6 8 10 12 14 16 18 20 Flow rate L/min Fig.9-14 Recirculating

Frequency (Hz), Remote controller IZS40 IZS41 IZS42 Remote controller Remote controller 0 1 2 3 4 5 6 7 8 9 1 3 1 0.1 5 3 0.5 8 5 1 10 10 3 15 15 5 20 20 10 30 30 15 DC+ DC+ 20 DC DC 30 Set when remote controller is used. 429 IZS40/41/42 Series Wiring Circuit/IZS41, 42 NPN specification Shield Ionizer (IZS41, 42) Green F.G. Ground with a ground resistance of 100 or less.

47 14 55 M12 x 1.5 86 112.5 5 39 27.5 114 228 50 64 64 20 55 78.5 10 58 17 58 M16 x 1.5 87.5 117 7 41 33 118.5 232.5 63 74 74 20 69 82 12 72 17 58 M16 x 1.5 91 120.5 5.5 48 39 122 236 Note) Refer to pages 13 and 14 for accessories.

NSR 18 Piston seal NBR 20 Tube gasket NSA ,-External dimensions are the same as the CS2 standard type. Refer to pages 7 to 10.

to 10 (832) Integrated time setting; -10 to 10 (833) Differentiation time setting; -10 to 10 Table 12 Amount of change when set value is increased/ decreased by 1 Set value is 0 or more Set value is less than 0 Prop. gain 10% 10% Integ. time 50% 10% Deffer. time 10% 10% 8: When automation calibration is performed, PID constant is automatically set.

(Conforming to DIN) Clip Without indicator light AXT100-20-1 Rated voltage With indicator light 16.8 Voltage symbol Part no. AXT100-20-2-05 AXT100-20-2-06 AXT100-20-2-01 AXT100-20-2-02 AXT100-20-2-03 AXT100-20-2-04 13.8 24 VDC 12 VDC 100 VAC 200 VAC 110 VAC 220 VAC 24V 12V 100V 200V 110V 220V 1. It is able to change the cylinder port between side ported and top ported.

AXT100-20-2-05 AXT100-20-2-06 AXT100-20-2-01 AXT100-20-2-02 AXT100-20-2-03 AXT100-20-2-04 Clip Circuit with light PR plate qChanging the piping direction from in-line to perpendicular (port on the valve) is possible on the VQZ100 series. Follow the steps below to change piping direction: Remove the fitting clips that hold the fitting and port plug in place.

Applicable rotary actuator Applicable air gripper Size Page Size 30 50-100 10/15 20-100 10/15 20-40 32/40 1/3 7/20 10-200 10-25 10-25 10-40 10-30 16-25 32-125 10-25 32-63 20-50 CDRA1 CDRB CDRQ MRQ MDSUB MSQ MHZ2 MHZJ2 MHL2 MDHR MHS 12-25 MHK MHS MHC2 MHT2 MHW2 10-25 10/16 MHY MRHQ 2.11-8 D-A72/A73/A80 Grommet D-A72H/A73H D-A76H/A80H 2.11-9 Rail Connector 2.11-10 D-A73C/A80C D-A53/A54/A56

Moment of inertia Rotation time 1.How to read graph When Moment of inertia 20 x 10-6 Rotation time 0.14s/90, MSUA 3 or MSUA 7, 20 will be selected. 2.Calculation example Shape of load: Column with a radius of 0.05m and weight of 0.12kg Rotation time: 0.2s/90 2 05 . 0 12 . 0 m kg I 2 6 10 150 2 Based on the graph of moment of inertia and rotation time, find the intersection by extending a

Input of set value Use the or buttons to set the flow value that will output 5 V (10 V) or 20 mA. The entered flow value can be in the range: 10% of the max. rated flow, to the upper display limit. Return to function selection mode. Press the S button to set.

"Line name communication data" Value (16 decimal 00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F number) 7 seg Display digit 11 seg Value (16 decimal 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F number) 7 seg Display digit 11 seg Value (16 decimal 20 21 22 23 24 25 26 27 28 29 2A 2B 2C 2D 2E 2F number) 7 seg Display digit 11 seg Remark The value of cannot be displayed -105No.PS-OMW0009

3 -20 3 1 4 Not specified Not specified 10,000 4 +3 4 5 5 Not specified Not specified 100,000 5 +7 6 +10 -19No.

Refer to catalog N366 Series Variations @ Boq1" l N m ) L lg) 10 16 20 25 32 40 50 MHY2NOD 10 0 . 1 6 71 70 MHY2N60 1 6 0.54 84 150 MHY2-MD 20 1 . 1 0 106 3m MHY2.25D 2.24 560 MHw2 Rack Style Unique seal design Grippng force when allows shorter total length construction and constant opening and closing fingers.

For details, refer to pages 3-7-19 and 3-7-20.

3.67 5.82 8.94 Temprature "F 32 30 20 l0 0 -10 -20 -30 40 s/fC (Shndard) .t37 I t A .083 .053 .033 .020 .ot2 .007 .004 g/ft' (Atmospheric) .r37 .177 .085 .056 .036 .023 .014 .009 .005 Tabla 3.7 Water Saturation of Air (Dew Point) The term g/tf standard rfers to a volume at gzoF. At BooF it.s volume is extended to l+ (80-32) or l.i tf 459?