Rated Flow Range: 0.5 to 4L/min, Flow Adjustment Valve: None, Thread: NPT, Port Size: 3/8, Output Specification: OUT1: Analog 1 to 5V, Temperature Sensor: None, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: Bracket, Calibration Certificate: None, Made to Order: Piping Material Brass
Model: VQC1000, Supply / Exhaust Port Entry: Cylinder Port Side, Port Size: 5/16 inch, Option: External Pilot
Model: VQC1000, Supply / Exhaust Port Entry: Cylinder Port Side, Port Size: 8mm, Option: External Pilot
Model: VQC2000, Supply / Exhaust Port Entry: Cylinder Port Side, Port Size: 3/8 inch, Option: External Pilot
Model: VQC2000, Supply / Exhaust Port Entry: Cylinder Port Side, Port Size: 10mm, Option: External Pilot
Model: VQC2000, Supply / Exhaust Port Entry: Cylinder Port Side, Port Size: 12mm, Option: External Pilot
Model: VQC2000, Port Size: 10mm, Option: External Pilot
Model: VQC1000, Port Size: 5/16 inch, Option: External Pilot
Model: VQC2000, Port Size: 3/8 inch, Option: External Pilot
Model: VQC1000, Port Size: 8mm, Option: External Pilot
Type: [Flow Switches] Flow Switch, Fluid Type: Air / Nitrogen Gas / Carbonic Acid Gas / Argon, Flow Range(l/min): 10~Less than 50, Sensor, Monitor Structure: [Separate Type Connector Connection] Separated sensor, Output Method: Analog, Analog Output Specification: Voltage, Pipe Port Type: Female Thread, Plumbing Thread Type: [Rc (R)] Rc, Plumbing Thread Nominal: [1/8] 1/8, Pressure Resistance
(MPa): 1, Flow Rate Type: Standard, Operating Temperature Range(°C): -10~60, Operating Humidity Range(%): 35~85, Number of Inputs: 2, Number of Outputs: 1, Analog Voltage Output(V): [DC1-5V] 1-5V, Power Supply Type: DC, Power Supply Voltage(V): [24] 24±10%, Pipe Connection Direction: 2-way, Connecting Tube Diameter: -, Liquid contact parts material: Resin + Metal, Mounting Hole: Presence,
(MPa): 1, Flow Rate Type: Standard, Operating Temperature Range(°C): -10~60, Operating Humidity Range(%): 35~85, Number of Inputs: 2, Number of Outputs: 1, Analog Voltage Output(V): [DC1-5V] 1-5V, Power Supply Type: DC, Power Supply Voltage(V): [24] 24±10%, Pipe Connection Direction: 2-way, Connecting Tube Diameter: -, Liquid contact parts material: Resin + Metal, Mounting Hole: Presence,
Flow Rate Type: Standard, Operating Temperature Range(°C): -10~60, Operating Humidity Range(%): 35~85, Number of Inputs: 2, Number of Outputs: 1, Analog Voltage Output(V): [DC1-5V] 1-5V, Power Supply Type: DC, Power Supply Voltage(V): [24] 24±10%, Pipe Connection Direction: 2-way, Connecting Tube Diameter: 6.35(1/4inch), Liquid contact parts material: Resin + Metal, Mounting Hole: Presence
(MPa): 1, Flow Rate Type: Standard, Operating Temperature Range(°C): -10~60, Operating Humidity Range(%): 35~85, Number of Inputs: 2, Number of Outputs: 1, Analog Voltage Output(V): [DC1-5V] 1-5V, Power Supply Type: DC, Power Supply Voltage(V): [24] 24±10%, Pipe Connection Direction: Back, Connecting Tube Diameter: -, Liquid contact parts material: Resin + Metal, Mounting Hole: Presence,
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
Please contact us for the latest version.sales@ocaire.com, F/R COMBO MODULAR, AIRLINE EQUIPMENT, AC MASS PRO, FA, AC MASS PRO 1/2 MODULAR (PT), 2.96777 lb, ModelComponentPort sizePressure gauge port size Note 1)FluidAmbient and fluid temperature Note 2)Proof pressureMaximum operating pressureSet pressure rangeRelief pressureNominal filtration ratingBowl materialBowl guardRegulator
Flow Range: 04 (0.4~4L/min), Tube Size: 11 (3/8), Output Specification: 1 (Pulse Output + Analog Output (1~5V)), Option: C (e-con Connector x 1 pc.)
Body Size: 40, Thread: Rc, Port Size: 04 (1/2), Option: Standard, Attachment: SV (S + V), Semi-Standard 1: 1 (0.02 to 0.2MPa Setting), Semi-Standard 2: Standard