-SV3000 U side (2 to 10 stations) D side (2 to 10 stations) Both sides (2 to 20 stations) Symbol 02 Stations Note 2 stations Double wiring Note 1) w SI unit specifications 16 02 16 stations y SUP/EXH block assembly 2 stations Symbol Communication connector Number of outputs Specified layout Note 2) (Available up to 32 solenoids) Protocol Nil R Internal pilot External pilot 20 0 QA QB NA NB
Because we have the spacer-installed type and the exclusive body type (-X10).
Note 2) Because the method for calculating the longitudinal dimension of the intermediate stroke varies between the spacer-installed style and the special body (-X10) style, refer to p.2.3-3 for details. 40 9 Depth 7 66 35 14 5.5 11 Depth 8 50 80 41 19 6.6 2.3-14 Compact Cylinder/Standard: Double Acting Single Rod Series CQ2 Foot (mm) Foot/CQ2L, CDQ2L W/o auto switch With auto switch Stroke
If the layout is specified, indicate it on the manifold specification sheet. i Mounting and Option Symbol Mounting Option Name plate Station number Nil Direct mounting 32 M12 NB NBN 16 NC NCN 32 *4 D-sub ND NDN 16 VA VAN CC-Link 32 M12 VB VBN 16 DA DAN EtherCAT 32 M12 DB DBN 16 FA FAN PROFINET 32 M12 FB FBN 16 EA EAN EtherNet/IP 32 M12 EB EBN 16 *3 GAN Ethernet POWERLINK 32 M12 *3 GBN 16
Driver Servo amplifier X10 STATION No. X1 5 5 6 6 4 4 3 3 7 7 2 2 8 8 1 1 9 9 0 0 Set the units. (initial value: 1) Set the tens. (initial value: 0) 3 6 3. CC-LINK COMMUNICATION FUNCTIONS 3.2.4 Communication baud rate setting Set the transfer baud rate of CC-Link with the transfer baud rate switch (MODE) on the driver front. The initial value is set to 156kbps.
Driver Servo amplifier X10 STATION No. X1 5 5 6 6 4 4 3 3 7 7 2 2 8 8 1 1 9 9 0 0 Set the units. (initial value: 1) Set the tens. (initial value: 0) 3 6 3. CC-LINK COMMUNICATION FUNCTIONS 3.2.4 Communication baud rate setting Set the transfer baud rate of CC-Link with the transfer baud rate switch (MODE) on the driver front. The initial value is set to 156kbps.
Because we have the spacer-installed type and the exclusive body type (-X10).
20P Type 23P Type 41 Type 42 Type 43 Type 41P Type 42P Type 43P Type SH compatible with NKE Corporation Uni-wire H System Type SV compatible with Mitsubishi Electric Corporation CC-LINK System Type SU compatible with JEMANET (JPCN-1) DIP.SW B RATE ADDRESS STATION NO. 0 0 0 1 1 1 PW LRUN 9 9 9 ON POWER ALARM COMM 1 2 2 2 ON 8 8 8 O N 3 3 3 7 7 7 0 4 4 4 6 6 6 SD RD LERR. 5 5 5 POWER SEND X10
Made to Order Specifications Oil-free specifications VCB X10 17-2-25 6 Series VCB Construction q w e r Component Parts t Material Description No.