Model: 50 (Side Ported), Connector Type: F (D-sub Connector, 25 Pins), Connector Entry Direction: 2 (Lateral), Wiring Specification: All Double Wiring, Valve Stations: 10 Stations, P,E Port Location: D Side, A,B Port Size: KN3 (ø5/32" One-touch Fitting, Replaceable), Thread: T (NPTF), Mounting: D0 (DIN Rail Mounting w/o DIN Rail)
Rated Flow Range: 11 (10 to 100 L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 06 (3/4), Output Specification: A (OUT1: NPN; OUT2: NPN), Temperature Sensor: T (Temperature Sensor), Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: J (Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °F)
Rated Flow Range: 11 (10 to 100 L/min), Flow Adjustment Valve: None, Thread: Rc, Port Size: 06 (3/4), Output Specification: A (OUT1: NPN; OUT2: NPN), Temperature Sensor: T (Temperature Sensor), Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: M (Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C)
Rated Flow Range: 11 (10 to 100 L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 06 (3/4), Output Specification: A (OUT1: NPN; OUT2: NPN), Temperature Sensor: T (Temperature Sensor), Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: M (Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C)
Model: 2 (SGC200), Valve Type: 1 (Normally Closed), Seal Material: A (NBR), Pressure Range: 16 (0 to 1.6 MPa), Thread: Rc, Port Size: 10 (3/8), Pilot Valve: Y (0.35 W Type, V116), Voltage: 1 (100 VAC 50/60 Hz), Electrical Entry: T (Conduit Terminal), Surge Suppressor: Z (With Light and Surge Voltage Suppressor)
Size: 1 (100), Valve Type: 1 (N.C.), Seal Material: A (NBR), Pressure Range: 70 (0 to 7 MPa), Thread: N (NPT), Port Size: 10 (3/8, SGH100), Pilot Valve: Y (V116, for 7 MPa), Voltage: 3 (110VAC/115VAC, 50/60 Hz), Electrical Entry: T (Conduit Terminal), Light/Surge Suppressor: Z (Light/Surge Suppressor, Non-polar)
Size: 1 (100), Valve Type: 0 (3-port), Seal Material: A (NBR), Pressure Range: 30 (0 to 3MPa), Thread: Rc, Port Size: 10 (3/8, SGH100), Voltage: 5 (24VDC), Electrical Entry: T (Conduit Terminal), Light/Surge Suppressor: Z (Light/Surge Suppressor, Non-polar), Manual Override: Non-locking Push Type, Bracket: B1 (Bracket on Left Side)
Model: 10 (200 L/min [ANR]), Pressure Range: 1 (0.005~0.1MPa), Power Voltage: 0 (24VDC), Input Signal: 0 (Current Style 4~20mADC), Monitor Output: 4 (Analog Output 4~20mA Sink Requires a Sourcing Type Analog Input Module), Thread: T (NPTF), Port Size: 2 [1/4 (1000,2000,3000)], Accessory: None, Cable Connector: S (Straight Style 3m)
Model: 10 (200 L/min [ANR]), Pressure Range: 3 (0.005~0.5MPa), Power Voltage: 0 (24VDC), Input Signal: 0 (Current Style 4~20mADC), Monitor Output: 4 (Analog Output 4~20mA Sink Requires a Sourcing Type Analog Input Module), Thread: T (NPTF), Port Size: 1 [1/8 (1000)], Accessory: None, Cable Connector: L (Right Angle Style 3m)
Model: 10 (200 L/min [ANR]), Pressure Range: 3 (0.005~0.5MPa), Power Voltage: 0 (24VDC), Input Signal: 0 (Current Style 4~20mADC), Monitor Output: 4 (Analog Output 4~20mA Sink Requires a Sourcing Type Analog Input Module), Thread: T (NPTF), Port Size: 1 [1/8 (1000)], Accessory: None, Cable Connector: N (w/oCable Connector)
Model: 10 (200 L/min [ANR]), Pressure Range: 3 (0.005~0.5MPa), Power Voltage: 0 (24VDC), Input Signal: 0 (Current Style 4~20mADC), Monitor Output: 4 (Analog Output 4~20mA Sink Requires a Sourcing Type Analog Input Module), Thread: T (NPTF), Port Size: 2 [1/4 (1000,2000,3000)], Accessory: None, Cable Connector: N (w/oCable Connector)
Model: 10 (200 L/min [ANR]), Pressure Range: 5 (0.005~0.9MPa), Power Voltage: 0 (24VDC), Input Signal: 0 (Current Style 4~20mADC), Monitor Output: 4 (Analog Output 4~20mA Sink Requires a Sourcing Type Analog Input Module), Thread: T (NPTF), Port Size: 2 [1/4 (1000,2000,3000)], Accessory: None, Cable Connector: N (w/oCable Connector)
/N.O.), Pilot: Internal Pilot, Back Pressure Check: None, Voltage: 5 (24VDC), Light & Surge Suppressor: U (Light & Surge Suppressor), Manual Override: Non-locking Push Style, Manifold Block: T (Tie Rod Base Type 10 Manifold Block), Manifold Wiring: Double, A, B Port: N1 (1/8" One-touch Fitting)
/N.O.), Pilot: Internal Pilot, Back Pressure Check: None, Voltage: 5 (24VDC), Light & Surge Suppressor: U (Light & Surge Suppressor), Manual Override: Non-locking Push Style, Manifold Block: T (Tie Rod Base Type 10 Manifold Block), Manifold Wiring: Double, A, B Port: N1 (1/8" One-touch Fitting)
Function: 1 (2 Position Single), Body Option: 10 (Base Mounted Non Plug-in), Pilot: Internal Pilot, Voltage: 3 (110~120VAC 50/60HZ), Lead Wire: T (Conduit Terminal), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: B (Locking Slotted Style)
Stations: 10 Stations, Port Size: N7 (1/4" One-touch Fitting), Kit Name: T (Terminal Box), Common: N (-COM), Option 1: None, Option 2: None, Option 3: None, Option 4: None, Option 5: S (Built-in Silencer, Direct Exhaust)
Stations: 10 Stations, Port Size: N7 (1/4" One-touch Fitting), Kit Name: T (Terminal Box), Common: 0 (+COM), Option 1: None, Option 2: None, Option 3: None, Option 4: None, Option 5: S (Built-in Silencer, Direct Exhaust)
Stations: 10 Stations, Port Size: 03 (Rc3/8), Thread Type: T (NPTF), Kit Name: SDZEN (EtherNet/IP), SI Unit COM: N (-COM), Number of Input Blocks: 2 (Input Block 2 pcs.), Input Block: 3 [M8, 4 Inputs (3 Pins)]
Stations: 10 Stations, Port Size: 02 (Rc1/4), Thread Type: T (NPTF), Kit Name: SDZEN (EtherNet/IP), SI Unit COM: N (-COM), Number of Input Blocks: 4 (Input Block 4 pcs.), Input Block: 3 [M8, 4 Inputs (3 Pins)]
Stations: 10 Stations, Port Size: 02 (Rc1/4), Thread Type: T (NPTF), Kit Name: SDZEN (EtherNet/IP), SI Unit COM: N (-COM), Number of Input Blocks: 5 (Input Block 5 pcs.), Input Block: 3 [M8, 4 Inputs (3 Pins)]