Type Bore size Nil H Pneumatic Air-hydro Note) 12 mm 16 mm 20 mm 25 mm 32 mm 40 mm 50 mm 63 mm 80 mm 100 mm 12 16 20 25 32 40 50 63 80 100 Body option Note) Bore sizes available for air-hydro type are 20 to 100.
[mm] Release button shape KQ2C-00A1 4, 6 Oval type KQ2C-00A 8 to 16 Round type U Union Y v Different diameter union Y v UD Different diameter double union Y v R Plug-in reducer v v Applicable tubing O.D. Symbol Size 04 4 06 6 08 8 10 10 12 12 16 16 3
Note 2) Use a bushing (part no:131368) when connecting the R1/8 pressure gauge to the Rc1/16. Note 3) 5 to 50C for the products with the digital pressure switch. Note 4) Not applicable to the AR10. 347 Series AR10 to AR60 Series AR20K to AR60K Options/Part No.
-400 KN-16-600 KN-20-400 KN-20-600 10 10 12 12 16 16 20 20 4 6 4 6 4 6 4 6 17 17 17 17 17 17 17 17 29.5 27.7 41.3 31.2 40.1 38.4 45.6 43.9 17 17 19 19 24 24 27 27 14 14 17 17 22 22 26 26 D H2 H1 L2 L1 Nozzle with Male Thread / KN (mm) Model Nozzle diameter D Connection size L1 A With across flats H1 Connection thread KN-R02-600 KN-R03-400 KN-R03-600 KN-R04-400 KN-R04-600 KN-R06-600 KN-R06
Lead Series Lead (Including Pn20E Pn210 symbol pulley ratio) A 12 65536 750 LEY25/LEYG25 B 6 375 LEY25D/LEYG25D C 3 131072 375 A 20 65536 1250 LEY32/LEYG32 B 10 625 LEY63D C 5 131072 625 A 16 1000 LEY B 8 500 LEY32D/LEYG32D C 4 250 65536 A 20 1250 B 10 625 C 5 131072 625 LEY63 5(2.86) L 229376 625 (Pulley ratio 4/7) H 20 1250 LEFS25 A 12 750 B 6 375 H 24 1500 LEFS32 A 16 1000 B 8 500 LEF
For details and solutions to alarms, see Section 16, Alarm Detection in the "Card Motor Controller (Step Data input edition)" operation manual. Caution Ensure the alarm history is cleared only after taking corrective action in response to the alarms.
Symbol Data type Data length Bit [byte] Description (IO-Link standard) U8 8 [1] UIntegerT Unsigned integer U16 16 [2] S16 IntegerT 16 [2] Signed integer F32 Float32T 32 [4] Floating point number 3: "Y" indicates that the parameter setting data is saved to the master, and "N" indicates that the parameter is not saved. -70No.PS-OMY0007-A [Selection of display items during standard setting]
Occupied byte Unit Unit part number Input Output EX600-SDNA (32 outputs) 0 4 EX600-SDNA (24 outputs) 0 3 SI unit EX600-SDNA (16 outputs) 0 2 EX600-SDNA (8 outputs) 0 1 EX600-DXB (8 inputs) 1 0 EX600-DXC (8 inputs) 1 0 EX600-DXC1 (8 inputs) (With open circuit detection) 1 0 Digital input unit EX600-DXD (16 inputs) 2 0 EX600-DXE (16 inputs) 2 0 EX600-DXF (16 inputs) 2 0 EX600-DYB (8 outputs
Spanner Nominal: 16 Tightening torque: 1.8 0.3 Nm Disassembly Phillips head screw driver 1) Remove the bonnet. Rotate the set screw counterclockwise with a Phillips head screw driver to remove the bonnet from the body. 2) Remove parts in order of the pressure adjustment screw assembly, spring, and the diaphragm assembly.
Note 9) Stainless steel rod standard on 7/16", 9/16", 3/4" and 7/8". Note 10) Exclude 7/16" and 9/16". Note 11) Exclude 2".
Body PBT 1 Valve NBR, Aluminum alloy 2 Spring Stainless steel 3 Spacer Brass Electroless nickel plated 4 Cassette 5 Seal NBR 6 Male Connector Type: AKH 4, 6 8 x R 1/8 5/32, 1/4 5/16 x NPT 1/8 M5 type U10/32 8, 10, 12 5/16, 3/8, 1/2 Free flow Fitting Male thread Description Material Note Parts list No.
16 5.2 10 12 15 8.3 32 30 32 36 6.5 8.5 8.6 2.5 3 3 63 (11) 50 14 34 69 (11) 68 14 39 14.5 16.5 49 30.4 34.7 4.7 4.9 7 8.1 25 30 11 14 14 M8 x 1.25 M10 x 1.5 M10 x 1.5 78 (13) 76 16 47 18.5 55 40.4 Size Rotation K Q S W Key dimensions TF (H9) TG (H9) TL JJ US TA TD G L UW TB TC M N b l 90 180 90 180 90 180 3 29 104 130 122 153 20 0 0.03 1 15 59 24.5 8 11 9.6 11.5 4 13.5 27 4 4 2.5 74 20
12 10 48 12.5 9 12.5 112 M6 24 24 34 M8 x 1.25 20 M8 x 1.25 6.6 32 25, 50, 75, 100 125, 150, 175 200, 250, 300 350, 400 91 69 16 12 10 54 14 10 14 120 M6 27 27 40 M8 x 1.25 20 M8 x 1.25 6.6 40 97 69 20 16 12 64 14 11 12 148 M8 32 32 46 M10 x 1.5 22 M10 x 1.5 8.6 50 102 74 20 16 12 78 16.5 13.5 16.5 162 M10 39 39 58 M10 x 1.5 22 M10 x 1.5 8.6 63 (mm) WB WA Bore size (mm) OB OL P PA PB PW
17 B 15 16 A 15 16 B 14 15 A 12 13 SMC D-A90 20 25 A Approx.
-With terminal block Junction cover/ classification t Boltom poding specification with "{2T" is 1/8'PA,B boflom and 1/4"4,8 side. ([48F2612{1-1A; see pg. 16) lUnit type individual station cover Stations ml2 stations r T I ql! stalSls Note: Individual cover part no. above, One.piece type, see pg. 16 Non DIN '.
E-M5 thread depth 10 6 5H9 Brake electrical circuit [Yellow] Brown +24V 38 46 76 0V White [Yellow] Note) A contact protection circuit is required when connecting a brake. 2-M2.5 thread depth 4 16 3 10 J 8 27 25 J x K Motor wire (300mm) Stroke + 246 Photo micro sensor wire (300mm) Brake wire (300mm) 13 15 Stroke + 127 (5) 0.5 46.5 3.5 2-M6 thread depth 13 75.5 59 52 27 [18] 15 Stroke + 127
Maximum of 16 stations for SI type.
Symbol Data type Data length Bit [byte] Description (IO-Link standard) U8 8 [1] UIntegerT Unsigned integer U16 16 [2] S16 IntegerT 16 [2] Signed integer F32 Float32T 32 [4] Floating point number 3: "Y" indicates that the parameter setting data is saved to the master, and "N" indicates that the parameter is not saved. -73No.PS-OMV0009-E [Selection of display items during standard setting]
Manual reverse button 16 forward speeds are available. Forward speed switch SPEED 16 reverse speeds are available. Reverse speed switch !8 16 forward acceleration steps are available. Forward acceleration switch ACCEL 16 reverse acceleration steps are available. Reverse acceleration switch CN1 Power supply connector Connect the power supply cable. !7 CN2 Connect the motor connector.
Quick Start . 16 8. Pneumatics . 16 8.1. Supply Pressure . 16 8.2. Power . 17 8.3. Network Cable . 17 8.4. Ethernet/IP (From PLC Perspective) . 18 8.5. IP Address . 18 8.6. MPC Default Parameters . 19 9. Ethernet/IP Network Parameters . 19 10. Network Specifications . 19 10.1. DLR (Device Level Ring) . 19 10.2. Hold on Connection Loss . 19 10.3. Hold Till Connection . 19 10.4.