BRAZIL SMC Pneumaticos do Brazil Ltda. CHILE SMC Pneumatics (Chile) S.A. PERU SMC Corporation Peru S.A.C. VENEZUELA SMC Neumatica Venezuela S.A. OCEANIA AUSTRALIA SMC Pneumatics (Australia) Pty. Ltd. NEW ZEALAND SMC Pneumatics (N.Z.) Ltd. EUROPE AUSTRIA SMC Pneumatik GmbH (Austria) BELGIUM SMC Pneumatics N.V./S.A.
Do not replace the non-rotating guide. Since the non-rotating guide is press fitted, the entire cover assembly needs be replaced instead of a single part. 37
Do not replace the non-rotating guide. Since the non-rotating guide is press fitted, the entire cover assembly needs be replaced instead of a single part. 38
Do not replace the bushings. The bushings are press-fit. To replace them, they must be replaced together with the cover assembly. 2. To replace a seal, apply grease to the new seal before installing it. If the cylinder is put into operation without applying grease to the seal, it could cause the seal to wear significantly, leading to premature air leakage. 3.
Do not service or attempt to remove product and machinery/ equipment until safety is confirmed. 1. The inspection and maintenance of machinery/equipment should only be performed after measures to prevent falling or runaway of the driven objects have been confirmed. 2.
Do not reuse if disassembled. High strength adhesive is applied to the portion of the connection that is threaded to prevent it from loosening, and it must not be disassembled. If it is forcefully disassembled, it could lead to damage. J J 2.The dust cover may stick to the stud.
Do not use an application to operate several cylinders simultaneously by adjusting cylinder speed. If this is inevitable, use a high rigid guide against load, so that the cylinder is not damaged even when the each cylinder output is slightly different. 4.
Do not cut the tube with cutting pliers, nippers, scissors, etc.) 2. Grasp the tube, then slowly push it until it comes to a stop. 3. Then, pull it back gently to make sure that it does not come out.
Note 5) Do not use the V-band type for gases. FGES/FGEL type (V-band type) FGET type (Bolt tightening type) Suitable for medium flow rate, low pressure filtration. Element replacement is easy with the V-band type.
Case Note 1) Cast iron Main material O-ring Material Nominal filtration NBR or FKM Note 2) Paper 5, 10, 20 m 0.6 MPa 0.275 MPa 0.35 MPa Element Differential pressure resistance Differential pressure indicator operating pressure (Element replacement differential pressure) Relief valve open pressure Note 1) There may be scratches, discoloration, slight paint peeling, or other defects which do
When washing the micromesh element, do not wipe it using a stiff brush or rag. 0.03 12 08 20 24 10 16 Pressure drop (MPa) 06 0.01 0.005 COM. N.O.
When installing and removing an element, do not scratch or damage it by touching the corners of the case, etc.
Do not allow the weight of piping to lie directly on air dryer. 4. Do not connect a tube smaller than the port size to the inlet side. In particular, when using a resin tube, make sure that the size would not be smaller than the port size.
With a surge absorption (surge absorption diode) mechanism B A 1021-VQ1000 1021-VQ2000 Caution Do not apply excessive torque when turning the locking type manual override. (0.1 Nm or less) 575 Series VQ1000/2000 Specific Product Precautions 2 1021Be sure to read this before handling.
Do not operate a cylinder with its bumper bolt removed. If the bumper bolt is removed, the piston hits the head cover, causing damage to the cylinder. Therefore, do not use a cylinder without a bumper bolt. 2. The piston rod must be retracted when mounting the cylinder.
. * If the step motor and servo motors do not meet your specifications, also consider the AC servo specification (Page 46). 38 Model Selection LEF Series Step Motor (Servo/24 VDC) Servo Motor (24 VDC) Clean Room Specication For the LECPA, refer to page 40.
Please do not rotate it any further than this. Note that the numbered scale markings are guidelines for adjusting the position, and not indicators of the dripping amount. 0.1 Pressure drop (MPa) 0.08 P1 = 0.7 MPa P1 = 0.5 MPa P1 = 0.3 MPa P1 = 0.1 MPa 0.06 0.04 0.02 0 0 2000 4000 6000 8000 Flow rate (L/min (ANR)) Caution 1. Check the dripping amount once a day.
Do not place a magnetic object near the pressure switch. Unintended operation may result. 2. Do not apply strong shocks (over 300 m/s2) to the pressure switch to prevent the switch from damage. AV AU AF Caution Flow rate (/min (ANR)) Inlet pressure (MPa) 1. Release the lock to adjust the pressure. After the adjustment, engage the lock.
Do not use two cylinders facing one another horizontally or vertically in such a way that their piston rods strike each other. 7. When the cylinder head side contains hydraulic fluid or is in a normally pressurized condition, the applied load must not be allowed to strike the piston rod end. Avoid such applications. 8.
In the case of auto switch rail mounting type, do not remove the rail that is mounted. Because retaining screws extend into the cylinder, this could lead to an air leak.