Fluid: air/inert gas, Operating pressure range: 0.1MPa - 0.7MPa (high pressure style 0.8MPa), Effective area mm 2 (Cv): metal seal 3.6 (0.2); rubber seal 5.4 (0.3), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, H 1.5W: 2 position metal seal 12 or less; 2 position rubber seal 15 or less 3 position metal seal 20 or less; 3 position rubber seal 25 or less
140, 160, 180, 200, Standard stroke (mm): 10 through 300, Port thread types:? Rc, NPT, G, Auto switch capable, CYLINDER, ACTUATOR, NCQ2-Z COMPACT CYLINDER, MX, 40MM NCQ2-Z DBL-ROD AUTO-SW, 7.63750 lb
140, 160, 180, 200, Standard stroke (mm): 10 through 300, Port thread types:? Rc, NPT, G, Auto switch capable, CYLINDER, ACTUATOR, NCQ2-Z COMPACT CYLINDER, FX, 12MM NCQ2-Z DBL-ROD AUTO-S, 18.70000 lb
Fluid: air/inert gas, Operating pressure range: 0.1 - 0.7MPa (high pressure type 0.8MPa), Effective area mm 2 (Cv): 2 position metal seal 14.4 (0.8); 2 position rubber seal 16.2 (0.9) 3 position metal seal 12.6 (0.7); 3 position rubber seal 14.4 (0.8), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, H 1.5W: metal seal 29 or less; rubber seal 34 or less
CYL, RODLESS, CLEAN ROOM, ACTUATOR, CY3R MAGNETICALLY COUPLED CYL, L5, 32MM CY3R CLEAN ROOM, 2.64554 lb, ModelBore size (mm)Port sizeLubricationStandard stroke (mm)Maximum manufacturable stroke (mm)Cushion RubberAir12-CY3R3232Rc1/8 NPT1/8 G1/8Non-lube100, 150, 200, 250, 300, 350,400, 450, 500, 600, 700, 8001300(Both sides)?
Please contact us for the latest version.sales@ocaire.com, GPL-200 RIGHT PISTON ASSY, ACTUATOR, GRIPPER, NC, 50MM GRIPPER, .00000 lb
Vibration resistance [m/s2] Note 3)Actuation typeGuide typeOperating temperature range [nC]Operating humidity range [%RH]Motor sizeMotor output [W]Motor typeEncoderRated voltage [V]Power consumption [W] Note 4)Standby power consumption when operating [W] Note 5)Max. instantaneous power consumption [W] Note 6)Type Note 7)Holding force [N]Power consumption [W] Note 8)HorizontalVerticalLEFS16A100, 200
Vibration resistance [m/s2] Note 3)Actuation typeGuide typeOperating temperature range [nC]Operating humidity range [%RH]Motor sizeMotor output [W]Motor typeEncoderRated voltage [V]Power consumption [W] Note 4)Standby power consumption when operating [W] Note 5)Max. instantaneous power consumption [W] Note 6)Type Note 7)Holding force [N]Power consumption [W] Note 8)HorizontalVerticalLEFS16A100, 200
Vibration resistance [m/s2] Note 3)Actuation typeGuide typeOperating temperature range [nC]Operating humidity range [%RH]Motor sizeMotor output [W]Motor typeEncoderRated voltage [V]Power consumption [W] Note 4)Standby power consumption when operating [W] Note 5)Max. instantaneous power consumption [W] Note 6)Type Note 7)Holding force [N]Power consumption [W] Note 8)HorizontalVerticalLEFS25A100, 200
Vibration resistance [m/s2] Note 3)Actuation typeGuide typeOperating temperature range [nC]Operating humidity range [%RH]Motor sizeMotor output [W]Motor typeEncoderRated voltage [V]Power consumption [W] Note 4)Standby power consumption when operating [W] Note 5)Max. instantaneous power consumption [W] Note 6)Type Note 7)Holding force [N]Power consumption [W] Note 8)HorizontalVerticalLEFS25A100, 200
Vibration resistance [m/s2] Note 3)Actuation typeGuide typeOperating temperature range [nC]Operating humidity range [%RH]Motor sizeMotor output [W]Motor typeEncoderRated voltage [V]Power consumption [W] Note 4)Standby power consumption when operating [W] Note 5)Max. instantaneous power consumption [W] Note 6)Type Note 7)Holding force [N]Power consumption [W] Note 8)HorizontalVerticalLEFS25A100, 200
When the LEF is ordered with the controller, initial data of the actuator is preset in the controller allowing start-up in a short time with the in.easy modein..Body size: 16, 25, 32, 40, Ball screw drive , Applicable stroke range: 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000, 2 types of motors: servo motor ball screw drive or step motor belt drive , Controller mounting: screw or DIN
When the LEF is ordered with the controller, initial data of the actuator is preset in the controller allowing start-up in a short time with the in.easy modein..Body size: 16, 25, 32, 40, Ball screw drive , Applicable stroke range: 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000, 2 types of motors: servo motor ball screw drive or step motor belt drive , Controller mounting: screw or DIN
Fluid: air/inert gas, Operating pressure range: 0.1MPa - 0.7MPa (high pressure style 0.8MPa), Effective area mm 2 (Cv): metal seal 3.6 (0.2); rubber seal 5.4 (0.3), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, H 1.5W: 2 position metal seal 12 or less; 2 position rubber seal 15 or less 3 position metal seal 20 or less; 3 position rubber seal 25 or less
Fluid: air/inert gas, Operating pressure range: 0.1MPa - 0.7MPa (high pressure style 0.8MPa), Effective area mm 2 (Cv): metal seal 3.6 (0.2); rubber seal 5.4 (0.3), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, H 1.5W: 2 position metal seal 12 or less; 2 position rubber seal 15 or less 3 position metal seal 20 or less; 3 position rubber seal 25 or less
Fluid: air/inert gas, Operating pressure range: 0.1 - 0.7MPa (high pressure type 0.8MPa), Effective area mm 2 (Cv): 2 position metal seal 14.4 (0.8); 2 position rubber seal 16.2 (0.9) 3 position metal seal 12.6 (0.7); 3 position rubber seal 14.4 (0.8), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, H 1.5W: metal seal 29 or less; rubber seal 34 or less
Fluid: air/inert gas, Operating pressure range: 0.1 - 0.7MPa (high pressure type 0.8MPa), Effective area mm 2 (Cv): 2 position metal seal 14.4 (0.8); 2 position rubber seal 16.2 (0.9) 3 position metal seal 12.6 (0.7); 3 position rubber seal 14.4 (0.8), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, H 1.5W: metal seal 29 or less; rubber seal 34 or less
Fluid: air/inert gas, Operating pressure range: 0.1 - 0.7MPa (high pressure type 0.8MPa), Effective area mm 2 (Cv): 2 position metal seal 14.4 (0.8); 2 position rubber seal 16.2 (0.9) 3 position metal seal 12.6 (0.7); 3 position rubber seal 14.4 (0.8), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, H 1.5W: metal seal 29 or less; rubber seal 34 or less
SY is available in body ported or base mounted styles and can be used individually or manifold mounted.Fluid: air , Operating pressure range: (internal pilot) 0.1 - 0.7MPa (external pilot) -100kPa to 0.7MPa (external pilot, pilot pressure range) 0.25 - 0.7MPa , Effective area mm 2 (Cv): body ported 10.6 (0.59); base mounted 12.6 (0.7) , Coil rated voltage: 3, 5, 6, 12, 24VDC; 100, 110, 200