SMC Corporation of America
Elite Part Number Search
Search Results "PVQ31-6G-40-01N-H-F"

Series: LEFS (Ball Screw Drive), Accuracy: H (High Precision Type), Size: 25, Motor Mounting Position: In-line, Motor: Step Motor (Servo 24 VDC), Lead Screw: H (Size 25: 20mm, Size 32: 24mm, Size 40: 30mm), Stroke: 450mm

A new high performance step motor controller, the JXC*H, pairs with the LEY*F actuator.  The machine's PLC can access the controller's operational and positional step data through several fieldbus protocols, IO-Link, or parallel I/O.  Actuator dimensions and mounting are identical to the standard LEY, allowing an upgrade for existing equipment. 

A new high performance step motor controller, the JXC*H, pairs with the LEY*F actuator.  The machine's PLC can access the controller's operational and positional step data through several fieldbus protocols, IO-Link, or parallel I/O.  Actuator dimensions and mounting are identical to the standard LEY, allowing an upgrade for existing equipment. 

A new high performance step motor controller, the JXC*H, pairs with the LEY*F actuator.  The machine's PLC can access the controller's operational and positional step data through several fieldbus protocols, IO-Link, or parallel I/O.  Actuator dimensions and mounting are identical to the standard LEY, allowing an upgrade for existing equipment. 

A new high performance step motor controller, the JXC*H, pairs with the LEY*F actuator.  The machine's PLC can access the controller's operational and positional step data through several fieldbus protocols, IO-Link, or parallel I/O.  Actuator dimensions and mounting are identical to the standard LEY, allowing an upgrade for existing equipment. 

A new high performance step motor controller, the JXC*H, pairs with the LEY*F actuator.  The machine's PLC can access the controller's operational and positional step data through several fieldbus protocols, IO-Link, or parallel I/O.  Actuator dimensions and mounting are identical to the standard LEY, allowing an upgrade for existing equipment. 

Special Applications: Clean Series, Body Size: 40, Reverse Flow: No, Thread: Rc, Port Size: 06 [3/4 (Size 40, 50)], Accessory, Not Attached: H [Set Nut for Panel Mount (Size 20 to 40)], Option: -

Special Applications: Clean Series, Body Size: 40, Reverse Flow: No, Thread: G, Port Size: 04 [1/2 (Size 40)], Accessory, Not Attached: H [Set Nut for Panel Mount (Size 20 to 40)], Option: None

Material: F (SCS14 Cover, SS 316 Case, Fluororesin Gasket/O-ring, Fluororesin Antistatic Spec. Seal), Element Length: B [ℓ500 (ℓ250 x 2)], Port Size: 06 (3/4 Rc), Element Type: H [Fiber (Honeycomb), Cotton Material], Nominal Filtration Accuracy: 1 μm

Material: F (SCS14 Cover, SS 316 Case, Fluororesin Gasket/O-ring, Fluororesin Antistatic Spec. Seal), Element Length: B [ℓ500 (ℓ250 x 2)], Port Size: 06 (3/4 Rc), Element Type: H [Fiber (Honeycomb), Cotton Material], Nominal Filtration Accuracy: 10 μm

Rated Distance Range: H (0.05 to 0.30mm), Piping Specifications: F (Supply Side: G 1/8, Detection Side: G 1/8), Output Specifications: N (NPN Output), Unit Specification: w/Unit Conversion Function, Stations: 1, Cable Option: L (Right Angle), Bracket Option: B (Bracket)

Rated Distance Range: H (0.05 to 0.30mm), Piping Specifications: F (Supply Side: G 1/8, Detection Side: G 1/8), Output Specifications: P (PNP Output), Unit Specification: w/Unit Conversion Function, Stations: 2, Cable Option: L (Right Angle), Bracket Option: B (Bracket)

Rated Distance Range: H (0.05 to 0.30mm), Piping Specifications: F (Supply Side: G 1/8, Detection Side: G 1/8), Output Specifications: P (PNP Output), Unit Specification: w/Unit Conversion Function, Stations: 1, Cable Option: L (Right Angle), Bracket Option: B (Bracket)

Rated Distance Range: H (0.05 to 0.30mm), Piping Specifications: F (Supply Side: G 1/8, Detection Side: G 1/8), Output Specifications: A (NPN, 2 Outputs), Unit Specification: w/Unit Conversion Function, Stations: 1, Cable Option: L (Right Angle), Bracket Option: B (Bracket)

Rated Distance Range: H (0.05 to 0.30mm), Piping Specifications: F (Supply Side: G 1/8, Detection Side: G 1/8), Output Specifications: N (NPN Output), Unit Specification: M (Fixed SI Unit), Stations: 1, Cable Option: L (Right Angle), Bracket Option: B (Bracket)

Rated Distance Range: H (0.05 to 0.30mm), Piping Specifications: F (Supply Side: G 1/8, Detection Side: G 1/8), Output Specifications: P (PNP Output), Unit Specification: w/Unit Conversion Function, Stations: 2, Cable Option: S (Centralized Lead Wire, Lead Wire Only)

Rated Distance Range: H (0.05 to 0.30mm), Piping Specifications: F (Supply Side: G 1/8, Detection Side: G 1/8), Output Specifications: P (PNP Output), Unit Specification: w/Unit Conversion Function, Stations: 3, Cable Option: S (Centralized Lead Wire, Lead Wire Only)

Rated Distance Range: H (0.05 to 0.30mm), Piping Specifications: F (Supply Side: G 1/8, Detection Side: G 1/8), Output Specifications: P (PNP Output), Unit Specification: w/Unit Conversion Function, Stations: 4, Cable Option: S (Centralized Lead Wire, Lead Wire Only)

Bearing Style: M (Slide Bearing), Mounting: F (Front Flange), Bore Size: 40mm, Thread: Rc, Stroke: 250mm, Lock Position: H (Rear Locking), Release of Manual: N (Non-locking Type), Auto Switch: C73--Reed, DC Volt >5 <24, AC Volt <100, LED, Lead Wire, 0.5M

Bearing Style: M (Slide Bearing), Mounting: F (Front Flange), Bore Size: 40mm, Thread: Rc, Stroke: 450mm, Lock Position: H (Rear Locking), Release of Manual: L (Locking), Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: L (3m)