Cylinder Bore Sizes (in inches) Valve Type Cv Type* 34 1 118 112 2 214 212 3 314 4 6 Micro-Line 0.11 SA F S S LTV 0.18 SA,DA F F F F M M M M S S Nova 1.00 SA,DA F F F F F F F M M Duramatic 0.18 SA,DA F F F F M M M M S S Duramatic 0.63 SA,DA F F F F F M M M M Capsula 0.75 SA,DA F F F F F F M M M Capsula 3.17 SA,DA F F F FT-1, FC-1 0.13 SA F F M S 4B-1, 4W-1 0.48 SA,DA F F F F M M M S FC51,
Lead Wire Lead wires with a connector indication Lead wire length indication Part No. of Lead Wires with Connectors (Applicable only for connector type) D-M9BW (Example) L Model Lead wire length D-LC05 0.5 m Symbol Lead wire length D-LC30 3 m Length 0.5 m 1 m 3 m 5 m None 0.5 m 1 m 0.5 m 1 m 0.5 m 1 m 3 m Solid state 2) Reed 3) Tolerance 15 mm 30 mm 90 mm 150 mm 15 mm 30 mm 15 mm 30 mm
Series VXZ22/23 Dimensions Grommet: G N.C.Normally closed: VXZ2230/2240/2350/2360 Bracket Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com N.O.Normally open: VXZ2232/2242/2352/2362 Bracket Port size Rc M L N.C. N.O. Model N.C. N.O.
1/4 Type M 0.6 Mass kg Type V 0.9 * Note 1.
L (Example) C73CL 5m . Z (Example) C73CZ None .
min] Flow rate gal/min [L/min] Flow rate gal/min [L/min] Input/Output Characteristics: Flow Rate (Representative Value) Inlet pressure: 44 psi (0.3 MPa) Fluid: Water LVR20 LVR40 LVR50 12 [45] 26 [100] 1.1 [4] 24 [90] 11 [40] 0.9 [3.5] Flow rate gal/min [L/min] Flow rate gal/min [L/min] Flow rate gal/min [L/min] 21 [80] 9.2 [35] 0.8 [3] 18 [70] 7.9 [30] 0.7 [2.5] 16 [60] 6.6 [25] 13 [50] 0.5
PCA-1558823 Cable with 7/8 inch connector, Socket, Straight 6 m PCA-1558836 Cable with 7/8 inch connector, Socket, Right angle 2 m PCA-1558849 Cable with 7/8 inch connector, Socket, Right angle 6 m PCA-1564927 Cable with M12 connector, B code, Socket, Straight 2 m, SPEEDOCON compatible PCA-1564930 Cable with M12 connector, B code, Socket, Straight 6 m, SPEEDOCON compatible PCA-1564943 Cable
Max. flow capacity L/min (ANR) 3F 4 30 4G 6 65 5H 8 130 7J 10 200 Plug-in type Bracket SFE-BR 3 Symbol Applicable model 3 SFE3l 4 SFE4l 5 SFE5l 7 SFE7l One-touch fitting type Specifications Model SFE11 SFE3 SFE4 SFE5 SFE7 Fluid Note 1) Air Maximum flow capacity Note 2) Up to 3 L/min (ANR) Up to 30 L/min (ANR) Up to 65 L/min (ANR) Up to 130 L/min (ANR) Up to 200 L/min (ANR) Filtration rating
Unit: N m Applicable models VHS20-D VHS30-D VHS40-D VHS40-06-D VHS50-D Max. moment (M) 14.5 16 19.5 35 45 Max. moment (M) = Length (L) x Load (F) Length (L) Load (F) 6. For piping into the exhaust port, recommended installing a silencer.
Caution Caution Solenoid valve for 200V,220V VAC specifications Solenoid valves with grommet and L/M type plug connector AC specification have a built-in rectifier circuit in the pilot section to operate the DC coil. With 200V, 220V VAC specification pilot valves, this built-in rectifier generates heat when energized.
Lead wire length symbols: 0.5 m Nil 3 m L 5 m Z None N Sincethereareotherapplicableautoswitchesthanlisted,refertopage1520fordetails. Fordetailsaboutautoswitcheswithpre-wiredconnector,refertopages1648and1649.
5.3 Temperature stability5 C 1 Rated ow (Outlet) L/min 45 (0.45 MPa) Circulating uid system Pump capacity Maximum ow rate L/min 130 Maximum pump head m 50 Minimum operating ow rate6 L/min 25 Tank capacity L 25 Circulating uid outlet, circulating uid return port Rc1 (Symbol F: G1, Symbol N: NPT1) Tank drain port Rc3/4 (Symbol F: G3/4, Symbol N: NPT3/4) Supply side pressure range MPa 0.2 to
M 3 m L 5 m Z None N Solid state auto switches marked with are produced upon receipt of order.
Note) When "JUMP instruction" is set for the control system, the "Da.9 Dwell time" and "Da.10 M code" setting details will differ. In cases when you selected "LOOP" as the control system, the "Da.10 M code" should be set differently from other cases. If "degree" is set for Pr.1 Unit setting", circular interpolation control cannot be carried out.
Plug Connector How to Use L/M Plug Connector How to Order 2. Crimping connection of lead wire and socket Caution L/M Plug Connector For JSY1000 Strip 3.2 to 3.7 mm at the end of lead wires, insert the end of the core wires evenly into the sockets, and then crimp it by a crimping tool.
D-A9V/M9V/M9WV/D-M9A(V)L types cannot be mounted. Do not indicate suffix N for no lead wire on D-A3/A44/G39/K39 models. -X Lead wire length symbols: 0.5 mNil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ None N (Example) H7CN Individual -X Since there are other applicable auto switches than listed, refer to page 1214 for details.
Volume of fluid in tank: 200 L 2. Pump-out volume: 100 L/min 3. Contaminant concentration of used fluid: 500 ppm (initial concentration, percentage by volume) 4. Number of separators: 2 pcs.
With One-touch fitting Port size U01 Uni 1/8 U02 Uni 1/4 U03 Uni 3/8 U04 Uni 1/2 Needle Valve/Flow Rate Characteristics AS2201F-U02, AS2211F-U02 AS2301F-U02, AS2311F-U02 AS2201F-U01, AS2211F-U01 AS2301F-U01, AS2311F-U01 600 300 Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa 06, 07, 08, 09, 10 500 08, 09, 10, 11 Flow rate L/min (ANR) Flow rate L/min (ANR) 03, 04 06, 07 200 400 01, 23 300
](mgCaCO3/L) 100 or less 50 or less 50 or less Total hardness (mgCaCO3/L) 200 or less 70 or less 70 or less Calcium hardness (mgCaCO3/L) 150 or less 50 or less 50 or less Ionic state silica (mgSiO2/L) 50 or less 30 or less 30 or less Iron (mg/L) 1.0 or less 0.3 or less 1.0 or less Copper (mg/L) 0.3 or less 0.1 or less 1.0 or less Reference items Sulfide ions (mg/L) Shall not be detected.
Filter Regulator AW20-B to AW60-B Filter Regulator with Backflow Function AW20K-B to AW60K-B Symbol Filter Regulator Filter Regulator with Backow Function 1 2 1 2 L L Integrated filter and regulator units save space and require less piping.