SMC Corporation of America
Elite Part Number Search
Search Results "CDJ2B16-30RZ-M9PWS-A"

Flow Rate Range: 25 [0.5 to 25 (25 for CO2) ℓ/min], Flow Adjustment Valve: Yes, Port Size: ø1/4 One-touch Fitting, Piping Entry Direction: Straight, Output Specification: 2 NPN Outputs, Unit Specification: Unit Switching Function, Instruction Manual: With Instruction Manual, Calibration Certificate: w/Calibration Certificate, Connector: -, Option: -

Flow Rate Range: 11 [2 to 100 (50 for CO2) ℓ/min], Flow Adjustment Valve: None, Port Size: Rc1/4, Piping Entry Direction: Straight, Output Specification: 2 NPN Outputs, Unit Specification: Unit Switching Function, Instruction Manual: With Instruction Manual, Calibration Certificate: w/Calibration Certificate, Connector: -, Option: -

Flow Rate Range: 50 [1 to 50 (25 for CO2) ℓ/min], Flow Adjustment Valve: Yes, Port Size: NPT1/8, Piping Entry Direction: Straight, Output Specification: 2 NPN Outputs, Unit Specification: Unit Switching Function, Instruction Manual: With Instruction Manual, Calibration Certificate: w/Calibration Certificate, Connector: -, Option: -

Flow Rate Range: 10 [0.2 to 10 (5 for CO2) ℓ/min], Flow Adjustment Valve: None, Port Size: ø6 One-touch Fitting, Piping Entry Direction: Straight, Output Specification: 2 NPN Outputs, Unit Specification: Unit Switching Function, Instruction Manual: With Instruction Manual, Calibration Certificate: w/Calibration Certificate, Connector: -, Option: -

Rated Flow Range: 102 (10 to 1000 L/min), Thread Type: Rc, Port Size: 04 (1/2), Output Specifications: A (Out 1: NPN; Out 2: NPN), Option 1: w/Lead Wire and M8 Connector, 3m, Unit Specification: Unit Selection Function, Option 2: No Bracket, Calibration Certificate: A (Yes)

SMC's PFM dual color digital flow switch was developed initially to detect microchip component adsorption in vacuum, and early clogging in both filter and nozzle applications.  The series is incredibly compact and lightweight compared to existing flow sensors.  The PFM is available in four maximum flow rate options 10, 25, 50 and 100 /min, and is suitable for use with air, nitrogen, argon

SMC's series HRG thermo-coolers control circulating fluid at a constant temperature.  Top panel access of the HRG makes maintenance easy. Various options include earth leakage breaker, and communications function (RS-485). 

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, 40MM C95/CP95 DBL-ACT AUTO-SW, ACTUATOR, C95/C96 TIE-ROD CYLINDER, ME, 40MM C95/CP95 DBL-ACT AUTO-SW, 2.75577 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, 63MM C95/CP95 DBL-ACT AUTO-SW, ACTUATOR, C95/C96 TIE-ROD CYLINDER, PE, 63MM C95/CP95 DBL-ACT AUTO-SW, 8.04687 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, RND BODY, DBL ACT, SW CAP, ACTUATOR, CM2/CM3 ROUND BODY CYLINDER, HE, 20MM CM2 DBL-ACT AUTO-SW, 1.433 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, 1 1/16" NCM DBL-ACT AUTO-SW, ACTUATOR, NCM ROUND BODY CYLINDER, JE, 1 1/16" NCM DBL-ACT AUTO-SW, 0.77579 lb

Conventional designed guided cylinders have a set bearing length resulting in dramatic decreases in side load capacity as stroke lengths increase. The MGP is the latest generation of guided cylinders and offers higher load capability, longer strokes, 2 port locations, switch mounting grooves on two sides, and a more versatile T-slot mounting than the MGQ series.

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL,AIR 1 1/4 BORE, AUTO-SW, ACTUATOR, NCM ROUND BODY CYLINDER, LE, 1.25 INCH NCM DBL-ACT AUTO-SW, .00000 lb, SeriesDescriptionModelActionNoteVol. no. (for std model)MB1Air cylinderMB1Double acting, Single rodExcept without air cushion666

M E N S I O N S AD S E R I E S A U I T O D R A I N S S Y M B O L S H O W T O O R D E R A U T O D R A I N S E R I E S AD AD402-02 (1/4) PT AD402-03 (3/8) PT AD402-04 (1/2) PT AD600-06 (3/4) PT AD600-10 (1) PT H O W T O O R D E R A U T O D R A I N S E R I E S NAD NAD402-N02 (1/4) NPT NAD402-N03 (3/8) NPT NAD402-N04 (1/2) NPT NAD600-N06 (3/4) NPT NAD600-N10 (1) NPT FOR FURTHER TECHNICAL DETAILS

, d e t e r i o r a t i o n o f a c c u r a c y, a n d breakage of parts.)

Using a regulator on the secondary side When mounting a regulator on the secondary side (A port side), use a residual pressure relief regulator (AR2550 to 4050) or a check type regulator (AR2560 to 6060). With a standard regulator (AR1000 to 6000), the secondary side pressure may not be released when this valve is exhausted. 5.

I f a p re s s u re g re a t e r t h a n t h e s e t p re s s u re i s re a c h e d , t h e u n i t w i l l o p e n , c l o s i n g w h e n p re s s u re i s l e s s t h a n s e t pressure.