(Confirm specifications.) 6. Locations with high moisture and dust. (Contact SMC in advance.) 2. Adhere to the fluid and ambient temperature ranges. The fluid and ambient temperatures are determined by the equipment being used. Operation beyond this range can cause damage, failure or malfunction, etc. Maintenance Warning 1.
Store away from direct sunlight in a location at no more than 40C. 1981-2000 Reprint May 2000 6
If the flow exceeds the rated flow rate even momentarily, this can cause drainage and oil to be sprayed into the downstream side, and damage to equipment. 6 Series AMP Air Cleaning Equipment Precautions 2 Be sure to read before handling. Piping Operating Environment Caution Warning 1.
VH Base mounted VHS Caution Pilot Pressure Range For Safety Instructions and Solenoid Valve Precautions, refer to pages 5-11-2 to 5-11-6. 0.6 Body ported Pilot pressure (MPa) Pilot pressure range 0.5 Series SYJA700 0.4 JIS Symbol 0.3 SYJA512 4 SYJA712 4 SYJA522 4 SYJA722 4 0.2 (A) 2 (A) 2 0.1 0.2 0.3 0.4 0.5 0.6 Operating pressure (MPa) 1 (P) 3 (R) 1 (P) 3 (R) N.C. N.O.
Refer to pages 5-11-2 to 6 for Safety Instruction and Solenoid Valve Precautions. 5-5-13 2 Series VPA300/500/700 Construction Standard Body ported Base mounted Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Vacuum (Option) Body ported Base mounted Component Parts
Port size (A, B port) Body type 01 02 1 8 1 4 For 60, 61 type manifold 6 R port of VFA370 is 1/4. For 70, 71 type manifold 7 How to Order Manifold Base Use the same manifold bases as the VF3000. VV5FA3 Specify the same manifold part number as VV5F3.
C J G5-S CV Fig. (6) Piping MVGQ Before connecting the pipes, remove any foreign matter.
Other reliable safety protection means should be adopted for such systems. 6. Ensure room for maintenance Leave sufficient space for maintenance work. 7. Releasing residual pressure Provide a residual pressure release function in order to carry out maintenance work. 8.
Cylinder with Lock/Double Acting, Single Rod Series CNS 125, 140, 160 Replacement Procedure is P.356 Construction $6 %1 $9 %4 %7 $7 $9 %3 %6 %2 %0 $8 %5 The numbers are the same as the "Construction" of the Best Pneumatics No.3 Series CNS. *BLUE links will lead to purchase pages. Seal Kit List Description Material Note No. Replacement Parts: Seal Kit Kit no.
(mm) 2 4 6 8 10 12 16 3.18 4.76 6.35 9.53 12.7 Burst Pressure Characteristics Curve and Operating Pressure Tubing I.D.
VQ7-6, Number of stations: 1-10, Wide range of interface options, MANIFOLD, VALVE, VS7-6 SOL VALVE 4/5 PORT, 22, VS7-6, .52910 lb
Manifold block ISO size 1, Applicable solenoid valve: VQ7-6, Number of stations: 1-10, Wide range of interface options, MANIFOLD, VALVE, VS7-6 SOL VALVE 4/5 PORT, 22, VS7-6, 3.08647 lb
Manifold block ISO size 1, Applicable solenoid valve: VQ7-6, Number of stations: 1-10, Wide range of interface options, MANIFOLD, VALVE, VS7-6 SOL VALVE 4/5 PORT, 22, VS7-6, 6.39340 lb
Manifold block ISO size 1, Applicable solenoid valve: VQ7-6, Number of stations: 1-10, Wide range of interface options, SUPPLY SPACER, VALVE, VS7-6 SOL VALVE 4/5 PORT, 22, VS7-6, .83775 lb
Manifold block ISO size 1, Applicable solenoid valve: VQ7-6, Number of stations: 1-10, Wide range of interface options, SUP RELOC SPACER 3/8 PT, VALVE, VS7-6 SOL VALVE 4/5 PORT, 22, VS7-6, .81233 lb
Manifold block ISO size 1, Applicable solenoid valve: VQ7-6, Number of stations: 1-10, Wide range of interface options, EXHAUST SPACER, VALVE, VS7-6 SOL VALVE 4/5 PORT, 22, VS7-6, .90327 lb
Manifold block ISO size 1, Applicable solenoid valve: VQ7-6, Number of stations: 1-10, Wide range of interface options, EXH. RELOCATION BLK ISO 1, VALVE, VS7-6 SOL VALVE 4/5 PORT, 22, VS7-6, .66446 lb
Manifold block ISO size 1, Applicable solenoid valve: VQ7-6, Number of stations: 1-10, Wide range of interface options, EXH RELOCATION BLOCK, VALVE, VS7-6 SOL VALVE 4/5 PORT, 22, VS7-6, .57251 lb
Manifold block ISO size 1, Applicable solenoid valve: VQ7-6, Number of stations: 1-10, Wide range of interface options, MANIFOLD, VALVE, VS7-6 SOL VALVE 4/5 PORT, 22, VS7-6, 3.08647 lb
Manifold block ISO size 1, Applicable solenoid valve: VQ7-6, Number of stations: 1-10, Wide range of interface options, MANIFOLD, VALVE, VS7-6 SOL VALVE 4/5 PORT, 22, VS7-6, 3.73562 lb