Rated Vacuum Range: -100 to 100 kPa, Output Specification: PNP Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: SI Unit Only, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Panel Mount Adapter, Operation Manual: Operation Manual, Calibration Certificate

Rated Vacuum Range: -100 to 100 kPa, Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Bottom Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: None, Operation Manual: Operation Manual, Calibration

Rated Vacuum Range: -101 to 0 kPa, Output Specification: PNP Open Collector 2 Outputs + Copy Function, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Bottom Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: -, Operation Manual

Rated Vacuum Range: -101 to 0 kPa, Output Specification: PNP Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Bottom Ported, Lead Wire: w/o Lead Wire, Bracket: Panel Mount Adapter + Front Protection Cover, Operation

Rated Vacuum Range: -100 to 100 kPa, Output Specification: NPN Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Bottom Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Panel Mount Adapter + Front Protection Cover

Rated Vacuum Range: -100 to 100 kPa, Output Specification: NPN Open Collector 2 Outputs + Copy Function, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Bottom Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: -, Operation

Rated Vacuum Range: -101 to 0 kPa, Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: w/o Lead Wire, Bracket: Panel Mount Adapter, Operation Manual: -

The series is available in six size options with a wide range o, BODY ASSY (NAF3000-N02), AIRLINE EQUIPMENT, AF FILTER, D2, AF 1/4INCH KIT/ACCESSORY, 0.638 lb

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof)

The ITV series is IP65 equivalent.Manifold for ITV1000/2000 Electro-Pneumatic Regulators, Up to 8 stations, Operation Manual, E/P REGULATOR, MFLD, INSTRUMENTATION, IT2000/ITV2000 E/P REGULATOR, 1X, IT2000 OTHER S(MISC./OTHER), 2.86000 lb

The ITV series is IP65 equivalent.Manifold for ITV1000/2000 Electro-Pneumatic Regulators, Up to 8 stations, Operation Manual, E/P REGULATOR, MFLD, INSTRUMENTATION, IT2000/ITV2000 E/P REGULATOR, 1X, IT2000 OTHER S(MISC./OTHER), 2.42508 lb

The ITV series is IP65 equivalent.Manifold for ITV1000/2000 Electro-Pneumatic Regulators, Up to 8 stations, Operation Manual, E/P REGULATOR, MFLD, INSTRUMENTATION, IT2000/ITV2000 E/P REGULATOR, 1X, IT2000 OTHER S(MISC./OTHER), .38940 lb

10%, Ripple (p-p) 10% or less (with power supply polarity protection)45 mA or lessNPN 1 output, NPN 2 outputs, PNP 1 output, PNP 2 outputs80 mA28 V (at NPN output)1 V or less (with load current of 80 mA)2.5 ms (with anti-chattering function: 20, 100, 500, 1000, 2000 ms)Yes?0.2% F.S. ?1 digitVariable (0 or above)Variable (0 or above)0.6 to 5 V ?2.5% F.S.?

10%, Ripple (p-p) 10% or less (with power supply polarity protection)45 mA or lessNPN 1 output, NPN 2 outputs, PNP 1 output, PNP 2 outputs80 mA28 V (at NPN output)1 V or less (with load current of 80 mA)2.5 ms (with anti-chattering function: 20, 100, 500, 1000, 2000 ms)Yes?0.2% F.S. ?1 digitVariable (0 or above)Variable (0 or above)1 to 5 V ?2.5% F.S.?

The ZSE80 series is a digital pressure switch designed to measure fluids such as tap water, hydraulic fluid, silicon oil, lubricant, fluorocarbon, argon, ammonia, carbon dioxide, air-containing drainage and nitrogen.  Some of the features include 2-color indication, select from back piping and bottom piping, the addition of 2MPa and -101kPa types, also low leakage type, water hammer protection

The ITV series is IP65 equivalent.Manifold for ITV1000/2000 Electro-Pneumatic Regulators, Up to 8 stations, Operation Manual, E/P REGULATOR, MFLD, INSTRUMENTATION, IT2000/ITV2000 E/P REGULATOR, 1X, IT2000 OTHER S(MISC./OTHER), 2.71150 lb

10%, Ripple (p-p) 10% or less (with power supply polarity protection)45 mA or lessNPN 1 output, NPN 2 outputs, PNP 1 output, PNP 2 outputs80 mA28 V (at NPN output)1 V or less (with load current of 80 mA)2.5 ms (with anti-chattering function: 20, 100, 500, 1000, 2000 ms)Yes?0.2% F.S. ?1 digitVariable (0 or above)Variable (0 or above)0.8 to 5 V ?2.5% F.S.?

The ISE80 series is a digital pressure switch designed to measure fluids such as tap water, hydraulic fluid, silicon oil, lubricant, fluorocarbon, argon, ammonia, carbon dioxide, air-containing drainage and nitrogen.? Some of the features include 2-color indication, select from back piping and bottom piping, the addition of 2MPa and -101kPa types, also low leakage type, water hammer protection

Please contact us for the latest version.sales@ocaire.com, Operation Manual, E/P REGULATOR, INSTRUMENTATION, IT2000/ITV2000 E/P REGULATOR, DB, IT2000 1/4 INCNPT VERSION, 2.16920 lb

Please contact us for the latest version.sales@ocaire.com, Operation Manual, E/P REGULATOR, INSTRUMENTATION, IT2000/ITV2000 E/P REGULATOR, DB, IT2000 1/4 INCNPT VERSION, 2.71150 lb