SMC Corporation of America
Elite Part Number Search
Search Results "NCDY2S32H-2000-A72H"

Stop filling once the level of Do not mount the product in a location with an altitude of more than 2000 fluid reaches the H mark. Cooling output Operation Mode: Initial mode meters. 5. Turn on the power switch to fill the piping with the fluid, then operate indicator Used in normal operation (e.g. setting of target temperature/offset.)

.: 25oC 1) Cooling capacity 1600 1400 Facility water 10oC Facility water 25oC 1200 Cooling capacity W 1000 Facility water 35oC 800 600 400 200 0 0 10 20 30 40 50 60 70 Recirculating fluid temp. oC Fig.9-11 Cooling capacity (HED007) 2) Heating capacity 3200 2800 2400 Heating capacity W Facility water 35oC 2000 1600 Facility water 10oC 1200 Facility water 25oC 800 400 0 0 10 20 30 40 50 60

Graph 1Allow lateral load 1000 Lateral load to rod end (N) 100 160 125&140 10 0 500 1000 1500 2000 Stroke(mm) Judging lateral load of dead weight In case of rotating type cylinder, lateral road applies to the piston rod because of dead weight of the cylinder. It needs to be checked, if the lateral load is within the range of safety.

(Value at the initial stage) Vibration resistance: 45 to 2000 Hz 1 sweep, no malfunction in the axial direction and perpendicular direction of the feed screw. (Value at the initial stage) Note5 Power indicates the maximum power during operation including the controller. Use this when selecting the power supply capacity. Note6 Only applies to actuators supplied with a lock.

Vibration resistance: No malfunction occurred in a test ranging between 45 to 2000 Hz. The test was performed in both an axial direction and a perpendicular direction to the lead screw. (The test was performed with the actuator in the initial state.) Note5) The power is for when the actuator is operating.

Vibration resistance: No malfunction occurred in a test ranging between 45 to 2000 Hz, when the actuator was tested in both an axial direction and a perpendicular direction to the lead screw. (The test was performed with the actuator in the initial state.) Note 5) Static allowable moment is the static moment applied to the actuator stopped.

(value at the initial stage) Vibration resistance: 45 to 2000 Hz 1 sweep, no malfunction in the axial direction and perpendicular direction of the feed screw. (value at the initial stage) Note 8Power indicates the maximum power during operation including the controller. Use this when selecting the power supply capacity.

Vibration resistance: No malfunction occurred in a test ranging between 45 to 2000 Hz. The test was performed in both an axial direction and a perpendicular direction to the lead screw. (The test was performed with the actuator in the initial state.) *8 The power (including the controller) is for when the actuator is operating.

(The test was performed with the actuator in the initial state) Vibration resistance: No malfunction occurred in a test ranging between 45 to 2000 Hz when the actuator was tested in both an axial direction and a perpendicular direction to the lead screw.

Vibration resistance: No malfunction occurred in a test ranging between 45 to 2000 Hz, when the actuator was tested in both an axial and perpendicular direction to the lead screw. (The test was performed with the actuator in the initialized state). Note 6) Maximum instantaneous power consumption (including the controller) is when the actuator is operating.

8.3 1. 2 ESTOP SVRE SETON 1 EMG (TB/) ESTOP SVRE SETON 2) 2 EMG (TB/) 1) ON OFF TB 2) SETON 3) 1.() INP ON, 3) 2 (8mm3mm) 5 - AREA 1 8 INP 100 8 () AREA 3 INP 100 3 () AREA 0.9 INP 1() 0.99. 99 OUT* 2) 1) ON OFF 2) DRIVEON OUT* DRIVEOFF IN* OUT*OUT*OFF OUT(LEC ) 5.4 (LEC ) (LEC ) () ID 1 164 1) IO 1: 64 1 S 0 (+) 1000.00 (-) -1000.00 /: 2,000 Max.2000

When the controller is turned ON next time, the default value (January 1st, 2000. 00:00:00) will be set. Therefore, set the date and time again. -13No. JXC-OMU0026 (a) Change to remote mode Change the mode to remote mode in the main window. When the mode is changed to the remote mode, the motors of the connected actuators will turn ON.

If the breaker with shorter operating time is connected, the customers equipment could be cut off due to the inrush current of the motor of this product. 4h 2h 1h 30min 20min 14min 10min 6min 4min MAX 2min 1min 30s 20s Operating time 10s 5s MIN 2s 1s 0.5s 0.2s 0.1s 0.05s 0.02s 0.01s 100 130 200 300 400 500 600700 1000 1500 2000 3000 4000 Current (% to the capacity of the main breaker of this

the feed holes Cable colour Signal Cable O.D. 4.0 to 8.0 mm Electric wire cross section (Twist line) AWG26 to 22 YE=Yellow or OGWH=Orange/ White 1 Orange/ White TD+ WH=White or GNWH=Green/ White 2 Green/ White RD+ 3 Orange OG=Orange TD4 Green BU=Blue or GN=Green RD-28No.EX-OMN0011-F (3) Cable with communication connector Part number: EX9-AC 01 0EN-PSRJ Cable length (L) 01 1000 [mm] 02 2000

the feed holes Cable colour Signal Cable O.D. 4.0 to 8.0 mm Electric wire cross section (Twist line) AWG26 to 22 YE=Yellow or OGWH=Orange/ White 1 Orange/ White TD+ WH=White or GNWH=Green/ White 2 Green/ White RD+ 3 Orange OG=Orange TD4 Green BU=Blue or GN=Green RD-34No.EX-OMO0030-E (3) Cable with communication connector Part number: EX9-AC 01 0EN-PSRJ Cable length (L) 01 1000 [mm] 02 2000

. -29No.EX-OMP0005-I Cable with both sides connector (SPEEDCON) Part number: EX9-AC 005 MJ SSPS (Socket/Plug) Cable length (L) Connecter specification 005 500 mm SSPS Socket side: Straight, Plug side: Straight 010 1000 mm 020 2000 mm SAPA Socket side: Angled, Plug side: Angled 030 3000 mm 050 5000 mm 100 10 mm Straight connector type (EX9-AC#MJ-SSPS) Angled connector type (EX9-AC#MJ-SAPA)

Only the solenoid valve/Output block LEDs do not light up Inconsistent polarity between the solenoid valve (VQC1000/2000) and output block Use common with the solenoid valve and Output block suitable for the PNP output of the SI unit. Check if the specifications of the SI unit match those of the solenoid valve and output block (+ common, common).

Inconsistent polarity between the solenoid valve (VQC1000/2000) and Output block. Check if the specifications of the SI unit match those of the solenoid valve and output block (+ common, common). Check the troubleshooting for the solenoid valve. Same as left. Failure of the solenoid valve and/or Output block.

(with polarity protection) Current consumption 40mA or less Switch output NPN or PNP open collector 2 outputs (To be selected) Maximum load current 80mA Max. applied voltage 28V (NPN output) Residual voltage Max. 2V (at 80mA load current) Response time 2.5 ms or less (response time available for anti-chattering function: 20, 100, 500, 1000 or 2000 ms) Short circuit protection Provided Repeatability

capacity Fluid: water Fluid: water 500 1400 Ambient 15C 1200 400 Cooling capacity W Cooling capacity W 1000 Ambient 15C 300 Ambient 35C 800 Ambient 20C Ambient 25C 600 200 400 Ambient 30C 100 200 0 0 10 15 20 25 30 35 40 45 50 10 15 20 25 30 35 40 45 50 Fluid temperature degC Circulating fluid temperature degC Fig. 6-1 Cooling capacity 2) Heating capacity Fluid: water Fluid: water 1000 2000