Proper tightening torque Body Lock nut width size [ Nm ] across flats Chamfer dimension D[mm] Connection M5 0.17 7 thread size (Recommended value) 1/8 0.3 9 M5 5.1 5.4 1/4 1 12 10-32UNF 5.0 5.3 3/8 1.5 14 1/2 2 17 Piping Threads with Sealant Caution (1) If the fitting is tightened with excessive (5)For R, NPT, G thread torque, a large amount of sealant will seep out.
Body size Symbol Symbol diameter 22 mm 26 mm 32 mm 5 6 16A 20A 25A 16 mm 22 mm 5 6 LVP6 Symbol Pilot port thread (fitting) type A Symbol Nil 1 2 N Thread (fitting) type 6 mm One-touch fitting Rc1/8 M5 x 0.8 NPT1/8 PA B N.C. A PB Option B Applicable valve type N.C. N.O. Double acting N.O.
Series SY3000/5000 Valve Replacement Parts 1 How to Order Port Block Assembly Mounting screw 0V 6A SY One-touch fitting Series 3 5 Thread type Nil F N T 3000 5000 Rc G NPT NPTF Pilot type Nil R A, B port size Thread piping Symbol Port size M5 01 Except M5 Internal pilot External pilot Option for mounting Nil 1 Applicable series SY3000 SY5000 M5 x 0.8 1/8 Standard (Valve mounting screw not
Size: 2 (M5 Basis), Style: 2 (Elbow), Thread: M3, M5, U10/32, R, Port Size: M5X0.8, Tube Size: Ø4, Sealant: w/o Sealant (M3,M5,U10/32), Option: None, Made to Order: None, Lock Nut: J (Round)
Size: 2 (M5 Basis), Style: 2 (Elbow), Thread: M3, M5, U10/32, R, Port Size: M5X0.8, Tube Size: Ø6, Sealant: w/o Sealant (M3,M5,U10/32), Option: None, Made to Order: None, Lock Nut: J (Round)
(a) Direct Mounting with four M5 screws Mounting screw (M5) 4pcs. (prepared by customer) (b) DIN rail mounting The figure on the right shows how to mount the DIN rail mounting brackets. Secure the DIN rail mounting bracket using the mounting screws (M5 x 8) 2 places on one side (4 places on both Mounting screw M5X8 sides).
One branch of manifold valves/input unit can be connected to 32 outputs/32 inputs. Up to 4 branches can be connected (total 128 outputs/128 inputs).
Description Material Note 31 Auto switch 32 Magnet 33 Switch spacer Resin 24 - Angle adjustable type Component parts No.
Applicable stroke table Size Stroke [mm] 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1000 1100 1200 25 32 40 25 - .
06 6 08 8 10 10 13 13 16 16 20 20 1 8 NPT N01 1 8 NPTF T01 1 8 25 25 32 32 40 40 50 50 Material Pad type (Refer to Table (1) for applications.)
CH2: Stainless steel, Alumina ceramic, Carbon, Fluororesin, PP, PBT, POM, PU, PVC, PPS, AS, PS, EPDM, NBR, Ion replacement resin Power supply 3-phase 200 VAC (50 Hz), 3-phase 200 to 230 VAC (60 Hz) Allowable voltage range 10% (No continuous voltage fluctuation) Earth leakage breaker Rated current [A] 30 40 50 Electrical system Sensitivity current [mA] 30 Rated operating current4 [A] 17 32
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
The connection M5 thread. Tighten thread to recommended torque value. 3. After installation, check internal leakage (leakage across seat) with inert gases. Perform a helium leak test depending on applications. Maintenance Warning 1.
Parts description of the air gripper JMHZ2-16D-X7400B-DTP-(N/P) Hexagon socket head cap screwsM6x23 Attachments Hexagon socket head cap screws M3X7 Auto switches D-M9(N/P)-5 Air gripper JMHZ2-16D Positioning pins3x6 Miniature Fittings: M-5ALHU-2 Adapter plate Polyurethane Tubings: O.D.2 One-touch fitting KQ2S04-M5N Metering Valve with Silencers: ASN2-M5-X937 3-port solenoid valves: V114-5LU
0.35 NCDRB1BW10 0.55 0.73 0.35 0.02 0.39 50 0.94 0.12 1.14 0.75 0.98 0 5-40 M5 (10-32NOM) -0.00015 -0.0014 (0.2) M3 -0.00045 3/16 0.47 NCDRB1BW15 0.71 0.73 0.39 0.02 0.59 50 1.14 0.16 1.34 0.94 0.98 0 5-40 M5 (10-32NOM) -0.01 -0.0017 (0.2) M3 -0.00017 15/64 9/16 NCDRB1BW20 0.79 0.98 0.39 0.02 0.79 50 1.42 0.18 1.65 1.32 1.00 0 8-32UNC 10-32UNF -0.00015 -0.0016 (0.28) -0.00045 5/16 5/8 NCDRB1BW30
N1: 1/8 N3: 5/32 N7: 1/4 Top ports are indicated by LN.
60 79.5 102.5 50 60 VXS24 1/2 29.5 69.5 67 61.5 55 110.5 63.5 79.5 109 50 63.5 VXS25 3/4 32 78 69.5 70 57.5 113 72 82 120.5 52.5 72 VXS26 1 32 81 69.5 72.5 57.5 113 74.5 82 126.5 52.5 74.5 Model Port size P 224 Zero Differential Pressure Type Pilot Operated 2 Port Solenoid Valve VXS Series For Steam Replacement Parts DIN Connector Part No.
AMH150-03 AMH250-03 AMH250-03 AMH350-04 AMH350-04 AMH450-06 AMH450-06 AMH550-06 AMH550-10 AMH650-14 AMH850-20 AMH850-20 IDG10-03 IDG20-03 IDG30-03 IDG50-03 IDG75-04 IDG100-04 AME150-03 AMF150-03 AME150-03 AMF150-03 AME250-03 AMF250-03 AME250-03 AMF250-03 AME350-04 AMF350-04 AME350-04 AMF350-04 AME450-06 AMF450-06 AME450-06 AMF450-06 AME550-10 AMF550-10 AME550-10 AMF550-10 AME650-14 AMF650
Closing the valve for initial pumping and the valve for main pumping When the initial and main pumping solenoid valves are de-energized, the valve S and M will return and start sealing. 9 XL-OMM0005-A 5 Dimensions 57.6 XLDV-25 (For AC) 55.4 (For DC) 2.2 8.5 C E B 1(P) D (KF flange) Fn G M5 1(P) SUP A M5 3(R) EXE H A XLDV-40160 C C E B 8.5 8.5 5.5 D (KF flange) Fd (K flange) M5 G Fn 1(P) SUP
(Recommended tightening torque: 0.4 to 0.5 Nm) 2) When piping fittings, etc. are connected to the air pressure supply (P) port (M5) for the single unit type, secure the part provided with the port, tighten it by hand, then additionally tighten by approximately one sixth to one fourth of a turn using an appropriate tool.