piping on left (CY1F10 to 25L--) KA KB EW 2-P Hexagon socket head bolt For adjustment bolt fixing HW ES (Piping port) 2-P (Hexagon socket head plug) EY HA GB EH KC KH H GB GA HB G GA N N KW A Z + Stroke Adjustment bolt GD GC Model Standard stroke EB A EA EH ES EW EY G GA GB GC GD H HA HB HW CY1F10 49 10 16 7 6.5 16 27 9 7 19.5 14 6 28 26 14 35.5 50,100,150,200,250,300 CY1F15 52.5 10 16 7
piping on left (CY1F10 to 25L--) KA KB EW 2-P Hexagon socket head bolt For adjustment bolt fixing HW ES (Piping port) 2-P (Hexagon socket head plug) EY HA GB EH KC KH H GB GA HB G GA N N KW A Z + Stroke Adjustment bolt GD GC Model Standard stroke EB A EA EH ES EW EY G GA GB GC GD H HA HB HW CY1F10 49 10 16 7 6.5 16 27 9 7 19.5 14 6 28 26 14 35.5 50,100,150,200,250,300 CY1F15 52.5 10 16 7
Antistatic One-touch fittings series KA has one-touch loading and unloading. Series KA can be used in copper- free applications and in vacuum (max. -100kPa). Conductive resin is used for body and seals in fittings and tubing. Series KA is flame resistant (UL94 standard, V-0).
Antistatic One-touch fittings series KA has one-touch loading and unloading. Series KA can be used in copper- free applications and in vacuum (max. -100kPa). Conductive resin is used for body and seals in fittings and tubing. Series KA is flame resistant (UL94 standard, V-0).
Antistatic One-touch fittings series KA has one-touch loading and unloading. Series KA can be used in copper-free applications and in vacuum (max. -100kPa). Conductive resin is used for body and seals in fittings and tubing. Series KA is flame resistant (UL94 standard, V-0).
The ZX is a single-stage vacuum generator. The modular design allows the user to choose only the components needed for the application. The ZX is available with a combination of generator unit, supply/release valve unit, pressure switch unit, and suction filter unit. Order without the generator unit for use as a filter and valve assembly for house vacuum systems. Special function plates
The ZX is a single-stage vacuum generator. The modular design allows the user to choose only the components needed for the application. The ZX is available with a combination of generator unit, supply/release valve unit, pressure switch unit, and suction filter unit. Order without the generator unit for use as a filter and valve assembly for house vacuum systems. Special function plates
The ZX is a single-stage vacuum generator. The modular design allows the user to choose only the components needed for the application. The ZX is available with a combination of generator unit, supply/release valve unit, pressure switch unit, and suction filter unit. Order without the generator unit for use as a filter and valve assembly for house vacuum systems. Special function plates
The ZX is a single-stage vacuum generator. The modular design allows the user to choose only the components needed for the application. The ZX is available with a combination of generator unit, supply/release valve unit, pressure switch unit, and suction filter unit. Order without the generator unit for use as a filter and valve assembly for house vacuum systems. Special function plates
The ZX is a single-stage vacuum generator. The modular design allows the user to choose only the components needed for the application. The ZX is available with a combination of generator unit, supply/release valve unit, pressure switch unit, and suction filter unit. Order without the generator unit for use as a filter and valve assembly for house vacuum systems. Special function plates
Unit Size: 7 (75mm), Cup Flange Shape: A (with Flange, 42mm x 42mm), Manufacturer: 11 (YASKAWA Electric Corporation: MOTOMAN-HC10DT), Cup Series: ZP (Basic), Cup Diameter: 32 (ø32), Cup Form: U (Flat), Cup Material: N (NBR), Attachment: with (Guide) Attachment
Unit Size: 7 (75mm), Cup Flange Shape: A (42mm x 42mm), Manufacturer: 21 (Fanuc: CRX-10iA, 10iA/L), Cup Series: ZP (Basic), Cup Diameter: 32 (ø32), Cup Form: U (Flat), Cup Material: N (NBR), Attachment: with (Guide) Attachment
Unit Size: 7 (75mm), Cup Flange Shape: A (42mm x 42mm), Manufacturer: 41 (OMRON, TECHMAN: TM5, TM12, TM14), Cup Series: ZP (Basic), Cup Diameter: 32 (ø32), Cup Form: U (Flat), Cup Material: N (NBR), Attachment: with (Guide) Attachment
Unit Size: 7 (75mm), Cup Flange Shape: A (42mm x 42mm), Manufacturer: 01 [UR: 3(e), 5(e), 10(e), 16(e)], Cup Series: ZP (Basic), Cup Diameter: 32 (ø32), Cup Form: U (Flat), Cup Material: N (NBR), Attachment: with (Guide) Attachment
Unit Size: 75mm, Cup Flange Shape: 42mm x 42mm, Manufacturer: OMRON, TECHMAN: TM5, TM12, TM14, Cup Series: Basic, Cup Diameter: ø32, Cup Form: Flat, Cup Material: NBR, Attachment: with (Guide) Attachment
Unit Size: 75mm, Cup Flange Shape: 42mm x 42mm, Manufacturer: Fanuc: CRX-10iA, 10iA/L, Cup Series: Basic, Cup Diameter: ø32, Cup Form: Flat, Cup Material: NBR, Attachment: with (Guide) Attachment
Unit Size: 75mm, Cup Flange Shape: with Flange, 42mm x 42mm, Manufacturer: YASKAWA Electric Corporation: MOTOMAN-HC10DT, Cup Series: Basic, Cup Diameter: ø32, Cup Form: Flat, Cup Material: NBR, Attachment: with (Guide) Attachment, Pressure Switch Output Spec/Unit: -
Unit Size: 75mm, Cup Flange Shape: 42mm x 42mm, Manufacturer: 01 [UR: 3(e), 5(e), 10(e), 16(e)], Cup Series: Basic, Cup Diameter: ø32, Cup Form: Flat, Cup Material: NBR, Attachment: with (Guide) Attachment
Doc.No.MH*-OMY0028 PRODUCT NAME Air Gripper for Collaborative Robots MODEL / Series / Product Number JMHZ2-16D-*-X7500AC-KA Contents Safety Instructions . 2 1List of included items . 4 2. Parts description of the air gripper . 5 3. Product Specifications . 6 3-1. How to order . 6 3-2. Specifications . 6 3-3. Auto switch . 7 3-4. Gripping force . 8 3-5. Gripping point . 9 3-6.
Doc no. LEC*-OMY0114-A PRODUCT NAME AC Servo Motor Driver (Pulse input type/Positioning type MODEL/ Series LECSB2-T Series This product can be used by adding a dedicated file (pushing operation extension file) to the setup software (MR Configurator2TM: LEC-MRC2E). Please download the dedicated file from SMC website. LECSB2-T Series / Driver 1. Safety Instructions These safety instructions