System: P (Vacuum Pump System, Single Unit), Valves: K (Supply Valve; N.C., Release Valve; N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: C (Digital Pressure Switch for Vacuum, 0 to -101, PNP 2 Outputs), Connector: L (L-type Plug Connector, Lead Wire w/Connector & Lead Wire for Pressure Switch), Vacuum, V Port: 08 (Metric Size, ø8 One-touch Fitting), Bracket: B [One Bracket for Mounting
System: P (Vacuum Pump System, Single Unit), Valves: K (Supply Valve; N.C., Release Valve; N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: C (Digital Pressure Switch for Vacuum, 0 to -101, PNP 2 Outputs), Connector: L (L-type Plug Connector, Lead Wire w/Connector & Lead Wire for Pressure Switch), Vacuum, V Port: 07 (Inch Size, ø1/4" One-touch Fitting), Bracket: w/o Option, Pump System PE
System: P (Vacuum Pump System, Single Unit), Valves: K (Supply Valve; N.C., Release Valve; N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: C (Digital Pressure Switch for Vacuum, 0 to -101, PNP 2 Outputs), Connector: L (L-type Plug Connector, Lead Wire w/Connector & Lead Wire for Pressure Switch), Vacuum, V Port: 08 (Metric Size, ø8 One-touch Fitting), Bracket: w/o Option, Pump System PE
In the case of characteristic a, time delav to switch a valve with switching pressure ps will be lt, b it will be increased lo t2.
In the case of characteristic a, time delav to switch a valve with switching pressure ps will be lt, b it will be increased lo t2.
(When setting 3 step, select each set value to be displayed by pressing the DOWN button.) When output operation mode is changed after selecting the 2 value display, the selected display items will not be applicable and [-] will be displayed.
Note) A total of up to 3 supply/exhaust blocks can be mounted. Contact SMC if 4 or more will be mounted.
Select the folder in which the step data is to be saved and save the data. Waveform data file (extension: gpf2) will be prepared. If the waveform condition needs to be checked, it can be displayed on the graph window. Click the Save Image button. Select the folder in which the step data is to be saved and save the data. An Image file (extension: jpg) will be prepared.
Select the folder in which the step data is to be saved and save the data. Waveform data file (extension: gpf2) will be prepared. If the waveform condition needs to be checked, it can be displayed on the graph window. Click the Save Image button. Select the folder in which the step data is to be saved and save the data. An Image file (extension: jpg) will be prepared.
A contact protection box should be used in any of the above situations. Otherwise, the life of the contacts may be reduced. (They may stay on continuously.)
Note) A total of up to 3 SUP/EXH blocks can be mounted. Please contact SMC if 4 or more will be mounted.
IP67 cannot be guaranteed if the screws are not tightened to the specified torque. 4. When lifting a large size manifold solenoid valve unit, take care to avoid causing stress to the valve connection joint. The connection parts of the unit may be damaged. Because the unit may be heavy, carrying and installation should be performed by more than one operator to avoid strain or injury. 5.
Avoid applications in which two or more cylinders with end lock are synchronized to move one workpiece, as one of the cylinder locks may not be able to release when required. 6. Use a speed controller with meter-out control. Lock cannot be released occasionally by meter-in control. 7. Be sure to operate completely to the cylinder stroke end on the side with the lock.
Note) A total of up to 3 SUP/EXH blocks can be mounted. Please contact SMC if 4 or more will be mounted.
Air consumption can also be reduced by controlling the pneumatic valve with a static neutralization completion signal. Note) The pneumatic valve must be separately procured.
Application requirements should be considered for appropriate model selection. Adsorption Confirmation Sensor installed close to the pad 1 Sensor installed close to the pad 2 PSE511 + PSE100 PS1100-R06L Pad adsorption can be confirmed easily. Response delays, caused by piping, will not be a factor due to the close proximity of the sensor to the pad.
Note) A total of up to 3 supply/exhaust blocks can be mounted. Contact P/A if 4 or more will be mounted.
Instruction manual The product should be mounted and operated after reading the manual carefully and having a good understanding of its contents. The manual should also be kept where it can be referred to whenever necessary. 2. Ensure sufficient maintenance space. Be sure to allow the space required for maintenance and inspections. 3.
Instruction manual The product should be mounted and operated after reading the manual carefully and having a good understanding of its contents. The manual should also be kept where it can be referred to whenever necessary. 2. Ensure sufficient maintenance space. Be sure to allow the space required for maintenance and inspections. 3.
After tightening by hand, the barb fitting type should be tightened by an additional 1/4 rotation using an appropriate wrench. 2. After tightening by hand, the barb elbow type should be tightened by an additional 1/2 rotation using an appropriate wrench. 2) M5 1. After tightening by hand, the barb fitting type should be tightened by an additional 1/6 rotation using a suitable tool. 2.