SMC Corporation of America
Elite Part Number Search
Search Results "VV2Q22-05-DO"

Do not use valves in atmospheres of corrosive gases, chemicals, salt water, water or steam, or where there is direct contact with them. 2. Do not use in an explosive atmosphere. 3. Do not use in locations subject to vibration or impact. Confirm the specifications in the main section of the catalog. 4. A protective cover, etc., should be used to shield valves from direct sunlight. 5.

Do not put the heavy objects on the products. Do not use the products as scaffold. 2. Do not use the products in conditions that do not meet the product specifications. Product Returns When returning the product to SMC, make sure to properly purge to remove all hazardous materials and return the product complying with SMC specified procedures.

Failure to do so may cause the angle adjusting screw to become loose or drop.

Do not use in an atmosphere having corrosive gases, chemicals, sea water, water, water vapor, or where there is direct contact with any of these. 2. Do not use in explosive atmospheres. 3. Do not use in locations subject to vibration or impact. 4. Do not use in locations where radiated heat will be received from nearby heat sources. 5.

Do not allow pallets to strike the lever when it is standing up. Do not allow pallets to strike the lever when it is standing up (after the shock absorber has absorbed energy), because the cylinder body will be subjected to the full energy of the impact. 2. Do not use a stopper cylinder for intermediate stopping of loads directly connected to a cylinder, etc.

Rotation should be controlled by connecting it to another shaft (linear guide, etc.). 3.Do not operate with the magnetic coupling out of position.

Do not use the drain tube in an upward direction. Do not bend or crush the drain tube. (Otherwise, the operation of an auto drain will stop and drainage will discharge through the air outlet.) If it is unavoidable that the tube goes upward, make sure it only goes as far as the position of the auto drain outlet.

Do not use an air containing mist or dust. The air containing mist or dust will cause the performance to decrease and shorten the maintenance cycle.

Do not use in locations having an explosive atmosphere. 2. Do not operate in locations where vibration or impact occurs. 3. In locations near heat sources, block off radiated heat. 1. Confirm model no., size, etc. before installing. Check tubing for damage, gouges, cracks, etc. The fluoropolymer tubing do not have the model number displayed on the product due to the resin material used.

Do not use with fluids other than compressed air. Cleaning equipment is designed exclusively for use with compressed air. Contact SMC in advance if a fluid other than compressed air is to be used. 2. Do not use compressed air which contains chemicals, organic solvents or corrosive gases.

(If you do not the power to OFF, it does not reflect the data in the driver.) Note2) Selected Items Write: It writes the parameter values of the corresponding frame to the driver. Single Axis Write: It writes all of the parameters to the driver. Note3) Do not change For manufacturer setting parameters.

(If you do not the power to OFF, it does not reflect the data in the driver.) Note2) Selected Items Write: It writes the parameter values of the corresponding frame to the driver. Single Axis Write: It writes all of the parameters to the driver. Note3) Do not change For manufacturer setting parameters.

Do not allow pallets to strike the lever when it is standing up. Do not allow pallets to strike the lever when it is standing up (after the shock absorber has absorbed energy), because the cylinder body will be subjected to the full energy of the impact. 2. Do not use a stopper cylinder for intermediate stopping of loads directly connected to a cylinder, etc.

Do not increase the operating speed after setting the operating conditions.

Do not direct the tip of the nozzle at the face or other parts of a human body. It may cause danger to personnel. 4. Do not use the product to clean or remove toxic substances or chemicals. 5. Do not drop, step on or hit the product. It may cause damage to the product. 6. Do not use the product to disturb public order or public hygiene. 7. This product is not a toy.

Elbow Universal 2 3 Metric size Inch size 3.2 23 01 1/8" 04 06 08 10 12 03 05 07 09 11 13 4 5/32" 6 3/16" Control 8 1/4" Meter-out Meter-in 0 1 10 5/16" 12 3/8" Use 1/8" tube. 1/2" M5 Port size With One-touch fitting M5 x 0.8 R 1/8 R 1/4 R 3/8 R 1/2 10-32 UNF NPT 1/8 NPT 1/4 NPT 3/8 NPT 1/2 01 02 03 04 U10/32 N01 N02 N03 N04 Needle Valve/Flow Characteristics AS1201FG, AS1211FG AS2201FG-

Size BTAuto switch mounting screws 1 1 M4 x 0.7 x 8L D-A5, A6 D-F5, J5 DBT-03, BT-04, BT-05 BT-06, BT-08, BT-12 BA4-040, BA4-063, BA4-080 BMB4-032, BMB4-050 D-Z7, Z8 D-Y5, Y6, Y7 2 2 M4 x 0.7 x 6L Set screw BMB5-032 BA7-040, BA7-063, BA7-080 D-A9 D-M9 BBA1 D-A5, A6 D-F5, J5 BT-16, BT-18A, BT-20 D-Z7, Z8 D-Y5, Y6, Y7 BS4-125, BS4-160 BS4-180, BS4-200 3 2 M4 x 0.7 x 8L Set screw D-A9 D-M9 BS5

Cable side connector example: OMRON Corporation XS2G Power connector: Franz Binder GmbH Series 723, 5 pins (72309-0115-80-05) Cable side connector example: Franz Binder GmbH 72309-0114-70-15, etc. DIN type 5 pins No. Function (+) Sensor power supply Description 2 1 SW + Open 2 N.C. 1 Description No.

"P 05 lS: _ .. , ~U ,8 Jl 2.5 --~ 3 45 3.5 24.5 15 12 4.5 2.3 ZPT3~ 32 35 1'4.5 25 8 40.5 '9.5 '::Deep type MOdel fA > 8 0 H :M6 Xl }i;MB X' : i .. ' C I E F I ~' I I f c I.E : F 1G , I i y j , ZPT25D 25 28 20 3 1 25.5125 1 51 I 8 3.5 1 315 15 146 1 ' 2 1 '0 I 10' Rat type Deep type/ ZPTlOD'16D only Flat type Deep type/ ZPT40D only H G ""\ ,.Q... h aclOSS fl~ W idl tM6 :S.M8: 1 2) rr:tl :