SMC Corporation of America
Elite Part Number Search
Search Results "VM133F-03-05"

Available in standalone or manifold configurations.Vacuum ejector, Stations: 01, 02, 03, 04, 05, 06, 07, 08, Right, left, or both side vacuum supply, MANIFOLD ASSY, 3-STA, VACUUM EJECTOR, 205 lb

3000 [mm] 05 5000 [mm] 10 10 [mm] Item Specifications Connector M12 Straight RJ45 Cable O.D. 6.4 mm Nominal cross section AWG26 Min. bending radius (Fixed) 26 mm (4) Seal cap Part number: EX9-AWTS This cap is used to protect the M12 connector opening when the connector is not used.

04 05 06 07 08 09 0A 0B 0C 0D 0E 0F 7seg Display letter 11seg Value (16 Hex number) 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F 7seg Display letter 11seg Value (16 Hex number) 20 21 22 23 24 25 26 27 28 29 2A 2B 2C 2D 2E 2F 7seg Display letter 11seg Supplementary information : Do not work Line name communication data -95No.PS-OMW0012-C Maintenance How to reset the product after a power

04 05 06 07 08 09 0A 0B 0C 0D 0E 0F Display letter 7seg 11seg Value (16 hex number) 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F Display letter 7seg 11seg Value (16 hex number) 20 21 22 23 24 25 26 27 28 29 2A 2B 2C 2D 2E 2F Display letter 7seg 11seg Supplementary information When is displayed, a reject response will be sent. -88No.PF-OMZ0002-A Troubleshooting If an operation failure

04 05 06 07 08 09 0A 0B 0C 0D 0E 0F Display letter 7seg 11seg Value (16 hex number) 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F Display letter 7seg 11seg Value (16 hex number) 20 21 22 23 24 25 26 27 28 29 2A 2B 2C 2D 2E 2F Display letter 7seg 11seg Supplementary information When is displayed, a reject response will be sent. -84No.PF-OMY0002 Troubleshooting If an operation failure of

04 05 06 07 08 09 0A 0B 0C 0D 0E 0F number) Display letter 7seg 11seg Value (16 hex 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F number) Display letter 7seg 11seg Value (16 hex 20 21 22 23 24 25 26 27 28 29 2A 2B 2C 2D 2E 2F number) Display letter 7seg 11seg -84No.PF-OMX0002-B Troubleshooting If an operation failure of the product occurs, please confirm the cause of the troubles from

04 05 06 07 08 09 0A 0B 0C 0D 0E 0F 7seg Display letter 11seg Value (16 Hex number) 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F 7seg Display letter 11seg Value (16 Hex number) 20 21 22 23 24 25 26 27 28 29 2A 2B 2C 2D 2E 2F 7seg Display letter 11seg Supplementary information : Do not work [Toggle output command] Value Item Remarks CH1 0 1 CH2 Measurement value 2 CH3 3 CH4 CH1_OUT1 16

ERR 00: CPU Hung up ERR 01: CPU Check Failure ERR 03: Back-up Data Error ERR 04: EEPROM Writing Error ERR 05: EEPROM Input Over Times Error ERR 11: DC Power Voltage Failure ERR 12: Internal Sensor Value is High ERR 13: Internal Sensor Value is Low ERR 14: Thermostat Alarm ERR 15: Output Failure Alarm (Abnormal output) ERR 17: Cutoff/Short of Internal Sensor ERR 18: Cutoff/Short of External

3000 [mm] 05 5000 [mm] 10 10 [mm] Item Specifications Connector M12 Straight RJ45 Cable O.D. 6.4 mm Nominal cross section AWG26 Min. bending radius (Fixed) 26 mm (4) Seal cap Part number: EX9-AWTS This cap is used to protect the M12 connector opening when the connector is not used.

3000 [mm] 05 5000 [mm] 10 10 [mm] Item Specifications Connector M12 Straight RJ45 Cable O.D. 6.4 mm Nominal cross section AWG26 Min. bending radius (Fixed) 26 mm (4) Seal cap Part number: EX9-AWTS This cap is used to protect the M12 connector opening when the connector is not used.

3000 [mm] 05 5000 [mm] 10 10 [mm] Item Specifications Connector M12 Straight RJ45 Cable O.D. 6.4 mm Nominal cross section AWG26 Min. bending radius (Fixed) 26 mm (4) Seal cap Part number: EX9-AWTS This cap is used to protect the M12 connector opening when the connector is not used.

(Drill through) Note) Dd9 L l d m H B C CJ1 D Cotter pin 3 x 18l 4 x 25l 4 x 35l 0.040 0.076 0.050 0.093 0.065 0.117 NT-03 NT-04 NT-05 NT-08 NT-10 CD-M03 CD-M05 CD-M08 10 14 22 32 40 50, 63 80 100 32, 40 50, 63 80, 100 3 4 4 44 60 82 36 51 72 M10 x 1.25 M14 x 1.5 M18 x 1.5 M22 x 1.5 M26 x 1.5 4 4.5 5 6 8 11 13 16 17 22 27 32 41 19.6 25.4 31.2 37.0 47.3 16.5 21 26 31 39 CJP CJ2 Note) When

Part no. 25 32 40 50, 63 0.040 0.076 0.040 0.076 0.040 0.076 0.050 0.093 CD-MU02 CD-MU03 CD-MU04 CD-MU05 25 32 40 50, 63 8 10 10 14 18.2 22.2 26.2 32.2 M10 x 1.25 M12 x 1.25 M14 x 1.5 M18 x 1.5 17 19 22 27 6 7 8 11 19.6 21.9 25.4 31.2 23 27 31 38 16.5 18 21 26 7.6 9.6 9.6 13.4 NT-03 NT-MU03 NT-04 NT-05 A nut is attached with rod end male thread as standard. (Double rod type: 2 pcs.)

Bore size (mm) 32, 40 50, 63 80, 100 Bore size (mm) 32 40 50 63 80 100 Mounting bracket BT-03 BT-05 BT-06 (1) MB-L03 MB-L04 MB-L05 MB-L06 MB-L08 MB-L10 Foot A set of following stainless steel mounting screws is attached. (A mounting bracket itself is not attached. Please order it separately.)

Bore size (mm) 32, 40 50, 63 80, 100 BT-06 Bore size (mm) 32 40 50 63 80 100 Mounting bracket BT-03 BT-05 (1) Foot MB-L03 MB-L04 MB-L05 MB-L06 MB-L08 MB-L10 A set of following stainless steel mounting screws is attached. (A mounting bracket itself is not attached. Please order it separately.)

The proper tightening torque for screws 0.3 to 0.4 Nm Rated voltage With indicator light VZ Voltage symbol Part no. 24 VDC 12 VDC 100 VAC 200 VAC 110 VAC 220 VAC 24V 12V 100V 200V 110V 220V AXT100-20-2-05 AXT100-20-2-06 AXT100-20-2-01 AXT100-20-2-02 AXT100-20-2-03 AXT100-20-2-04 VS (b) VFN Valve Mounting Circuit with Indicator Light After confirming the gasket is correctly placed under the

DXT170-176-2-01 DXT170-176-2-02 100V 200V 100 VAC 200 VAC DXT170-176-2-03 110V 110 VAC DXT170-176-2-04 220V 220 VAC DXT170-176-2-07 DXT170-176-3-51 DXT170-176-3-06 DXT170-176-3-05 DXT170-176-3-53 240V 6VD 12VD 24VD 48VD 240 VAC 6 VDC 12 VDC 24 VDC 48 VDC Circuit with Indicator Light AC circuit DC circuit NL: Neon bulb R: Resister D: Protective diode LED: Light emitting diode R: Resistor 4

DXT170-176-2-01 DXT170-176-2-02 100 VAC 200 VAC 100V 200V DXT170-176-2-03 220V 110V 110 VAC DXT170-176-2-04 220 VAC DXT170-176-2-07 DXT170-176-3-51 DXT170-176-3-06 DXT170-176-3-05 DXT170-176-3-53 240 VAC 240V 6VD 12VD 24VD 48VD 6 VDC 12 VDC 24 VDC 48 VDC Circuit with Indicator Light AC Circuit diagram DC Circuit diagram D: Protective diode LED: Emitting diode R: Resister NL: Neon bulb R:

Valve; w/Stop Valve), Supply/Return Port Size: 03 (3/8), Return Unit Flow Switch Output Specifications: 1T (Out 1: Analog 1 to 5 V; Out 2: Flow Rate: None; Temp.: Analog 1 to 5 V; Temperature Sensor: Yes)

Cart SMC SY100-82-2-01 y conncector, SY3000 SOL/VALVE, RUBBER SEAL*** $7.79 + Add to Quote Add To Cart Add to Cart SMC SY100-82-2-03