Symbol Stations 02 24 Symbol Stations 02 24 D side U side 1 3 2 Stations 2 stations 24 stations 2 stations 24 stations Up to 24 solenoids possible. PG: Flat ribbon cable (20 pins) PH: Flat ribbon cable (10 pins) SUP/EXH block (D side mounting) Note Up to 18 solenoids possible. Note Up to 8 solenoids possible.
Round Square embedded type Round Square embedded type G46-10-02 G36-10-01 1.0MPa Note 3) GC3-10AS Note 2) GC3-10AS GC3-10AS 1 4 1 8 1 4 Note 1) Pressure gauge G46-2-02 G36-2-01 G46-2-02 Set pressure + 0.05MPa (at relief flow rate of 0.1l/min(ANR)) 5 to 60C (With no condensation) 5m 0.2MPa Note 3) GC3-2AS GC3-2AS GC3-2AS Note 4) AD48 N.O.
Calculation example Message for BCC [STX] 01RPV1 [ETX] Calculation ASCII HEX [STX] 02 0 30 1 31 R 52 P 50 V 56 1 31 [ETX] 03 e 65 Code for EXOR from STX to ETX is BCC. Sending message [STX] 01RPV1 [ETX] e 5.7 Command Table 5.7-1 shows the commands which are supported by the product. No response is returned for a request message of a command which is not in Table 5.7-1.
Calculation example Message for BCC [STX] 01RPV1 [ETX] Calculation ASCII HEX [STX] 02 0 30 1 31 R 52 P 50 V 56 1 31 [ETX] 03 e 65 Code for EXOR from STX to ETX is BCC. Sending message [STX] 01RPV1 [ETX] e 5.7 Command Table 5.7-1 shows the commands which are supported by the product. No response is returned for a request message of a command which is not in Table 5.7-1.
Single numerical data instructions (1 Stations occupied) [Remote IO] PLC memory PLC memory address Signal name address Signal name Rx Ry 00 OUT0 00 IN0 01 OUT1 01 IN1 02 OUT2 02 IN2 03 OUT3 03 IN3 04 OUT4 04 IN4 05 OUT5 05 IN5 06 06 07 07 08 BUSY 08 HOLD 09 SVRE 09 SVON 0A SETON 0A DRIVE 0B INP 0B RESET 0C AREA 0C SETUP 0D WAREA 0D JOG(-) 0E ESTOP 0E JOG(+) 0F ALARM 0F FLGTH 1A to 10
Single numerical data instructions (1 Stations occupied) [Remote IO] PLC memory PLC memory address Signal name address Signal name Rx Ry 00 OUT0 00 IN0 01 OUT1 01 IN1 02 OUT2 02 IN2 03 OUT3 03 IN3 04 OUT4 04 IN4 05 OUT5 05 IN5 06 06 07 07 08 BUSY 08 HOLD 09 SVRE 09 SVON 0A SETON 0A DRIVE 0B INP 0B RESET 0C AREA 0C SETUP 0D WAREA 0D JOG (-) 0E ESTOP 0E JOG (+) 0F ALARM 0F FLGTH 10 to 1A
220-02-F 320-03 (02) 320-03-F (02) 420-04 420-04-F 121F-M3 131F-M3 121F-M5 (U10, 32) 131F-M5 (U10, 32) 221F-01 231F-01 2211F-01-06 221F-02 231F-02 321F-03 (02) 331F-03 (02) 421F-04 431F-04 1000F 2000F 2050F 3000F 4000F 1001F 2001F 2051F 3001F 4001F 230F 330F 430F 530F 630F 330F 430F 530F 630F Manifold regulator 4-, 5-port solenoid valve VQ Directional control valves 0 1000 2000 4000 5000
Manual override P L 5 24 VDC 02 Rc 1/4 (8A) Rc 3/8 (10A) 9 Other 03 3-9-1 Series VS410 Accessory (Option) Apparent Power (Power Consumption) 1.
Precautions FH150-02 to 04 q Mounting Confirm IN and OUT before mounting.
Description Material AS800 AS900 y u i JIS B 2401 P-7 JIS B 2401 P-7 AQ NBR O-ring u O-ring O-ring Spring NBR NBR Stainless steel JIS B 2401 P-12 JIS B 2401 G-50 14115 JIS B 2401 P-16 JIS B 2401 G-65 14124 JIS B 2401 P-48 JIS B 2401 P-38 NBR O-ring ASV i AK ASS Dimensions: AS420/500/600 Dimensions: AS800/900 ASR ASF 2-Port size 2-Port size Dimensions Dimensions L1 L2 L4 Min.
Table of contents P 1 2. How to order P 2 3. Specifications P 2 4. External dimensions drawing P 3,4 5. How to mount a nozzle P 5,6 6. Safety Instructions P 710 -1- 2. How to Order IBG1 0 02 Adjuster Symbol Type 0 Without adjuster 1 With adjuster Supply port Nozzle (Refer to page 4 for details.)
m P 0.1 x m + m P D 1.6 x D 5.0 x D 5.0 x m m mv P Pv m > mv P > Pv Determination of allowable load mass & pressure Inclined operation (Refer to page 8-16-8
NARM 2500 05 A 02 G1 Optimal for central pressure control. Accessory Regulator for manifold Pressure easily set using the new handle. One-touch lock system.
Description With foot bracket Note For VZ312 0 3 DXT170-34-1B AN120-M5 Noise reduction: 21dB or more (8 x 17 mm) Silencer 3-3-18 5 Port Solenoid Valve Body Ported Series VZ3000 Flow Characteristics/Weight Flow characteristics Note) Port size Valve model Type of actuation Weight (g) 1 4/2 (P A/B) 4, 2 (A, B) 1, 5, 3 (P , EA, EB) 4/2 5/3 (A/B EA/EB) b C [dm3/(sbar)] b C [dm3/(sbar)] Cv
SS5Y3-42-02-C6 1 unit SY3140-5LOZ 2 units o Cable assembly for output entry. EX510-VW10S 1 pc. !0 Output unit . EX510-DYN3 1 unit !1 2 port solenoid valve . VX2120-02-5GS1 1 pc. Two branch connectors are attached to the manifold including the SI unit and two are attached to the input unit and the output unit respectively.
Used as IO-Link device 18 to 30 VDC, including ripple (p-p) 10% Current consumption 35 mA or less Protection Polarity protection Display accuracy 2%F.S.1 digit (at ambient temperature 253 oC) Accuracy Repeatability 0.5%F.S. Temperature characteristics (25 oC standard) 5%F.S. Output type Select from NPN or PNP open collector output.
How to Order IZN10 01 P 06 Z B1 IZN10 High frequency AC nozzle type Series name Nozzle shape NIL 01 02 11 Piping female Note 1) Rc1/8 Type Energy saving charge elimination nozzle Large flow nozzle Output specification NIL NPN P PNP Piping diameter 06 f6: metric 07 f6.351/4"): inch 16 f6: metric (elbow) 17 f6.351/4"): inch (elbow) Power supply cable NIL 3m Z 10m N Not provided Bracket NIL
Note 2) Refer to p.5.3-5 for lead wire length.
The series and their stopping accuracy are as follows: CLJ series (p.3.1-10), CLM2 series (p.3.1-18), CLG1 (p.3.127), CLA series (p.3.1-35), and CL1 series (p.3.1-50). wWhen kinetic energy acts upon the cylinder, such as when effecting an intermediate stop: There are constraints in terms of the allowable kinetic energy that can be applied to the cylinder in a locked state.