100ms) 5 / 5ms ()/60ms () RS-232C NPN PNP NPN PNP Max DC30V 50mA Max DC30V 50mA Max DC30V 50mA Max DC30V 50mA AC100 AC100 AC100 AC100 DC24V DC24V DC24V DC24V 240V 240V 240V 240V (10%) (10%) (10%) (10%) (10%) (10%) (10%) (10%) 20VA 10W 20VA 10W 20VA 10W 20VA 10W AC : AC1500V,1 : AC500V,1 AC :DC500V,50M 0 +50() 35 85%RH() (1s) 2000V,600V 1055Hz 0.75mm X,Y,Z 2 10G
Ball screw shaft Approximately 6 months Grease pack order number (Arrange separately) GR-S-010 (10g), GR-S-020 (20g), GR-S-400 (400g) Please contact us for the Maintenance Manual. 3. It is recommended that apply the appropriate covering to the electric actuator in the environment of splashing the liquid other than water.
Emax 0.43 5=0.841 OK ML2B32 P19 21 5-1 () 25 32 40 0.10.8MPa 0.30.5MPa 1.2MPa 0.75MP 1001500mms( 100500mms) 560 mm 0+1.8 JIS B0209 Rc1/8 Rc1/4 5 6 8 5-2 CEU2 CEU2P (DIN ) PRESET PROGRAM RUN LCD() 116132 P.T.P point to point 1 9.9 0.1mm RAM 8K 5mm 4 2 END NPN DC30V50mA PNP DC30V50mA AC100V1550Hz/60Hz DC24V100.4A 050 2585 10~55Hz0.75mm XYZ 2 1s 1500V600V 10G
101.2kPa to 0.1 {1Torr to 1} VKF33 W (for low power consumption/vacuum) 2.7 (0.15) 2 3 VKF334 4.5 (0.25) 0 to 0.7 {0 to 7.1} VKF334Y (for low power consumption, DC2W) 2.7 (0.15) Base mounted VKF334E (for long loading time) Rc(PT) 1/8 2.7 (0.15) 120 VKF334V (for vacuum) 4.5 (0.25) 101.2kPa to 0.1 {1Torr to 1} VKF334W (for low power consumption/vacuum) 2.7 (0.15) Y E V W Note 1) VKF332 ( ): Add 10g
Food Machinery Grease Specification Standard models -XC85 Grease pack part number: GR-H-010(10g) Nonfood compound incidental contact. Operating Environment Caution Environment for installing cylinder Do not use in food zone. 32 5.
Add the conduit 10g, the DIN connector 30g, and the terminal 60g respectively.
Grease pack part number: GR-R-010 ( 10g ) 1. Rod seal Apply a thin layer of grease to all surfaces of the new seal to make it easy to mount the rod seal and improve sealing. Fill the groove of the seal with grease, which is necessary for operation. 2. Piston seal Apply a thin layer of grease to the all surfaces of the piston seal to make it easy to mount the seal. 3.
Food Machinery Grease Specification Standard models -XC85 Grease pack part number: GR-H-010(10g) Nonfood compound incidental contact. Operating Environment Caution Environment for installing cylinder Do not use in food zone. 4-2.
Insulation resistance Between external terminal batch and case: 2M (at 500VDC) 2hrs. each in X, Y, Z directions at smaller of 10 to 500Hz with amplitude 1.5mm, or acceleration 10G Vibration resistance 100G in X, Y, Z directions, 3 times each Impact resistance Note 1) Not available on analog output type. Refer to CAT.E824-A "Pressure Switch" for details on switches.
Food Machinery Grease Specification Standard models -XC85 Grease pack part number: GR-H-010(10g) Nonfood compound incidental contact. Operating Environment Caution Environment for installing cylinder Do not use in food zone. 4-2.
.: GR-L-010 (10g) MGT D-X Individual -X 415 Series MGF Dimensions: 40 MGF40 120 4 x M8 x 1.25 through 100 100 120 90 9.5 8 46 + Stroke 36.5 + Stroke 7.5 18.5 2 x Rc, NPT, G 1/8 Breathing hole for guide (with element) 38 When the cylinder is extended Port for extending cylinder Port for retracting cylinder 114 4 x M8 x 1.25 through M5: T-slot for hexagon bolt K 3.5 40 100 120 114 8.7 6 x K
Grease pack is included in the seal kit shown above. (10g for 32, 40, 50. 20g for 63, 80, 100) If only the grease pack is required, order using the following part number. Part number for grease: GR-S-010 (10g), GR-S-020 (20g) As shown above, there are 2 types of construction for cylinder depending on the production condition.
Grease pack part number: GRD -005 (5g), GR-D-010 (10g), GR-D-100 (100g) 1) Rod seal Apply a thin layer of grease to all surfaces of the new seal to make it easy to mount the rod seal and improve sealing.
A Grease NoGR-S-010 (10g) Lock pin Piston rod of built-in shock absorber Do not remove the grease applied to the piston rod end of the built-in shock absorber. Periodically check the condition of this and apply grease as necessary. Figure-7 (4) Do not let your hand become caught when operating the cylinder. The lever holder goes up and down while the cylinder is in operation.
Grease pack part number: GR-S-010 (10g), GR-S-020 (20g) 1) Rod seal Apply a thin layer of grease to all surfaces of the new seal to make it easy to mount the rod seal and improve sealing.
(See Fig. 10) Grease part number:GR-S-010(10g) Pin B Grease applied Bracket Piston rod of the built-in shock absorber Grease applied Fig.10 9 - Please do not remove the grease applied to the piston rod end of the built-in shock absorber and periodically check the condition of the grease. 10. Maintenance Service 10-1.
Grease pack is included in the seal kit shown above. (10g for 32, 40, 50. 20g for 63, 80, 100) If only the grease pack is required, order using the following part number. Part number for grease: GR-S-010 (10g), GR-S-020 (20g) C a u t i o n The seal is not delivered in sealed packaging for independent storage, so it must be used within 1 year. 4-1-2.
Grease pack is included in the seal kit shown above. (10g for 32, 40, 50. 20g for 63, 80, 100) If only the grease pack is required, order using the following part number. Part number for grease: GR-S-010 (10g), GR-S-020 (20g) As shown above, there are 2 types of construction for cylinder depending on the production condition.
Part name Amount 9 Slider 2pcs CRA1U50 P694020-22 Tube gasket 2pcs 11 CRA1U63 P694030-22 12 Piston seal 2pcs Spring pin 4pcs 19 CRA1U80 P694040-22 40 Seal washer 1pcs CRA1U100 P694050-22 (Grease pack) (10g) Description Model Product No.
Applicable load 24VDC relay, PLC Power supply voltage Current consumption Load voltage 24VDC (10 to 28VDC) Grease pack for stainless steel cylinders/Part number: GR-R-010 (10g) Load current 5 to 40mA Internal voltage drop 4V or less Leakage current 0.8mA or less at 24VDC Actuated position .